Sample Certificate of Analysis
USP · 20%
Sample COA. Contact Alliance Chemical with your lot number to request a lot-specific COA.
Sample specification reference for Propylene Glycol 20% USP GRADE. Source-record results are reference values, not measurements for your lot.
| Parameter | Specification | Source reference result | Test Method |
|---|---|---|---|
| Assay | 20.0 - 21.0 %, by volume | 20.18 % | — |
| Freeze point | 18.7 °F (-7.4 °C) max | 18.5 °F (-7.5 °C) | ASTM D1177 |
| Dilution water | Purified Water USP; conductivity ≤ 1.3 µS/cm @ 25 °C | Passes test | USP <1231> / conductivity USP <645> |
| Acidity | not more than 0.04 mL of 0.10 N sodium hydroxide | 0.01 | USP monograph titration, 0.10 N NaOH |
| Chloride | 0.0015% max | 0.0000045 % | USP <221> |
| Heavy metals | 1 ppm max | 0.06 ppm | Heavy metals (as Pb), sulfide colour comparison against lead standard |
| Iron | 0.11 ppm max | 0.007 ppm | — |
| Limit of Diethylene Glycol | 0.021% max | 0.00035 % | GC, flame ionization detector, 0.53-mm x 30-m fused-silica G43 column, 2,2,2-trichloroethanol internal standard |
| Limit of Ethylene Glycol | 0.021% max | 0.000088 % | GC, flame ionization detector, 0.53-mm x 30-m fused-silica G43 column, 2,2,2-trichloroethanol internal standard |
| Residue on ignition | 0.0016 wt% max | 0.00010 wt% | Ignition of 50 g, residue moistened with 0.5 mL sulfuric acid and ignited to constant weight |
| Sulfate | 0.0013% max | 0.00006 % | USP <221> |
| arsenic | 0.21 ppm max | 0.0052 ppm | — |
| dpg | 0.021 % max | 0.0069 % | — |
| pb | 0.21 mg/kg max | 0.0017 mg/kg | — |
| meg | 0.00021 % max | 0.00009 % | — |
| po | 0.00021 % max | 0.000045 % | — |
| tpg | 0.0062 % max | 0.0014 % | — |
| Color, Pt-Co | 10 APHA (maximum) | 1 APHA | Platinum-cobalt (APHA) color scale |
| Odor | Pass | Passes test | Sensory (odor) evaluation |
| Residual solvents | Pass | Passes test | USP <467> |
| Suspended matter | Pass | Passes test | — |
| Composition | 20 % propylene glycol / 80 % deionized water, by volume | Conforms | By formulation; confirmed by specific gravity |
Specification limits and source-record results are reproduced from the current product reference used by the TDS. This sample is not an issued certificate and does not identify a tested lot. Contact Alliance Chemical with the product and lot number for lot-specific documentation.
Tell us the lot number from the container label and we will send the certificate over at no charge.