Certificado de análisis de muestra
Food · 25%
COA de muestra. Contacte con Alliance Chemical con su número de lote para solicitar un COA específico de ese lote.
Referencia de especificaciones de muestra para Glycerin 25% Food Grade. Los resultados del documento fuente son valores de referencia, no mediciones de su lote.
| Parámetro | Especificación | Resultado de referencia del documento fuente | Método de ensayo |
|---|---|---|---|
| Assay (glycerol) | 24.0 - 26.0 % | 25.3 % | — |
| Fatty acids and esters | not more than 0.25 mL of 0.5 N sodium hydroxide consumed | 0.03 | USP saponification / residual titration on a 50 g sample |
| Heavy metals | 1.25 ppm max | 0.41 ppm | — |
| lead | 0.26 ppm max | 0.0050 ppm | — |
| Related compounds (total impurities, including diethylene glycol) | 0.25% max | 0.012 % | USP gas chromatography, area normalization |
| related compounds | 0.025 % max | 0.01 % | — |
| Chloride | 0.00028% max | 0.000034 % | — |
| Chlorinated Compounds | 0.00075% max | 0.000062 % | Morpholine reflux followed by silver-nitrate turbidity comparison |
| Diethylene Glycol | 0.025% max | 0.0013 % | Gas chromatography with flame-ionization detection |
| Ethylene glycol | 0.025 % max | 0.0008 % | USP 41 (Identification Test B, gas chromatography) |
| Individual Impurities, excluding Diethylene Glycol | 0.025% max | 0.0042 % | Gas chromatography with flame-ionization detection |
| Related compounds (any individual impurity other than diethylene glycol) | 0.025% max | 0.0042 % | USP gas chromatography, area normalization |
| Residue on Ignition | 0.0027% max | 0.00075 % | Ignition of a 50 g sample followed by sulfuric-acid treatment and ignition to constant weight |
| Sulfate | 0.00057 % max | 0.000051 % | USP <221> |
| Total Impurities, including Diethylene Glycol | 0.25% max | 0.012 % | Gas chromatography with flame-ionization detection |
| Color (APHA) | 10 Max APHA | 2 APHA | AMT-FGQ-G10 |
| Composition | 25 % glycerol in deionized water, by weight | Conforms | By formulation; confirmed by specific gravity |
Los límites de especificación y los resultados del documento fuente se reproducen de la referencia actual del producto utilizada en la ficha técnica. Esta muestra no es un certificado emitido y no identifica un lote analizado. Contacte con Alliance Chemical indicando el producto y el número de lote para obtener documentación específica del lote.
Indíquenos el número de lote que figura en la etiqueta del envase y le enviaremos el certificado sin cargo.