Exemple de certificat d'analyse
USP Grade
Exemple de COA. Contactez Alliance Chemical avec votre numéro de lot pour demander un COA propre à ce lot.
Exemple de référence de spécifications pour Potassium Bicarbonate - FCC USP Grade. Les résultats du document source sont des valeurs de référence, et non des mesures de votre lot.
| Paramètre | Spécification | Résultat de référence du document source | Méthode d'essai |
|---|---|---|---|
| Assay (KHCO3, dried basis) | 99.5 - 101.5 % | 100.3 % | Acidimetric titration with 1 N hydrochloric acid VS using methyl red TS (1 mL = 100.1 mg KHCO3) |
| Description / Appearance | Colorless, transparent, monoclinic prisms or white, granular powder; stable in air | Passes test | Visual |
| Arsenic (as As) | 1.5 ppm by wt. Max. | 0.045 ppm by wt. | Elemental impurities (USP <232>/<233> style ICP determination) |
| Cadmium (as Cd) | 0.2 ppm by wt. Max. | 0.007 ppm by wt. | Elemental impurities (USP <232>/<233> style ICP determination) |
| Carbonate (FCC limit test) | Passes test (solution does not immediately turn more than a faint pink color) | Passes test | Dissolve 1 g without agitation in 20 mL water at not above 5 degrees C, add 2 mL 0.1 N hydrochloric acid and 2 drops phenolphthalein |
| Heavy Metals (as Pb) | 5 ppm max | 0.8 ppm | — |
| Identification | A 1:10 aqueous solution gives positive tests for Potassium and for Bicarbonate | Passes test | Chemical identity tests for Potassium and for Bicarbonate on a 1:10 aqueous solution |
| Lead (Pb) | Not more than 2 mg/kg | 0.057 mg/kg | APDC Extraction Method under Lead Limit Test, FCC Appendix IIIB |
| Loss on Drying | Not more than 0.25 % | 0.061 % | Dried over silica gel for 4 hours (FCC Appendix IIC) |
| Loss on Drying - USP acceptance criterion | Not more than 0.3 % | 0.061 % | Dry over silica gel for 4 hours |
| Mercury (as Hg) | 0.3 ppm by wt. Max. | 0.010 ppm by wt. | Elemental impurities (USP <232>/<233> style ICP determination) |
| Normal Carbonate | max. 2.5% | 0.35 % | — |
| Residual Solvents | Meets Requirements | Passes test | USP <467> (not required where no solvents are used in manufacture) |
| Bulk Density (informational, not a specification) | ~64 lb/cu.ft (published as informational only, not a specification item) | Passes test | Loose bulk density |
| pH (1% w/v aqueous solution @ 25 C) | 8.0 - 8.6 | 8.2 | USP <791> / potentiometric, calibrated glass electrode |
| Chloride (as Cl) | 0.001 % max | 0.0006 % | USP <221> chloride limit test / argentometric titration |
| Sulfate (as SO4) | Not more than 0.01 % | 0.0014 % | USP <221> sulfate limit test, turbidimetric against standard |
| Iron (Fe) | Not more than 5 mg/kg | 0.30 mg/kg | ICP-OES (FCC iron limit test) |
| Screen Analysis (sieve) | 100 % through 20 mesh (850 um); not more than 10 % through 200 mesh (75 um) | Passes test | ASTM E11 sieve stack / Ro-Tap, 10 min |
| calcium | 0.002 % max | 0.00018 % | — |
| insoluble | 0.01 % max | 0.0017 % | — |
| magnesium | 0.001 % max | 0.00013 % | — |
| tot. alk | 99.5 - 101.5 Wt.% | 100.3 Wt.% | — |
| cd | 0.2 Wt.ppm max | < 0.01 | — |
Les limites de spécification et les résultats du document source sont reproduits à partir de la référence produit actuelle utilisée par la fiche technique. Cet exemple n’est pas un certificat délivré et n’identifie aucun lot analysé. Contactez Alliance Chemical en indiquant le produit et le numéro de lot pour obtenir la documentation propre au lot.
Indiquez-nous le numéro de lot figurant sur l'étiquette du contenant et nous vous enverrons le certificat sans frais.