Sample Certificate of Analysis
Sample COA. Contact Alliance Chemical with your lot number to request a lot-specific COA.
Sample specification reference for Kerosene - K1 Clean Burning Fuel. Source-record results are reference values, not measurements for your lot.
| Parameter | Specification | Source reference result | Test Method |
|---|---|---|---|
| Distillation, final boiling point | 300 °C max | 272 °C | ASTM D86 |
| Saybolt color | +16 min | +30 | ASTM D156 |
| Copper strip corrosion, 3 hr @ 100 °C | 3 max | 1a | ASTM D130 |
| Distillation, 10 % vol. recovered | 205 °C max | 189 °C | ASTM D86 |
| Flash point | 38 °C min | 48 °C | ASTM D56 (Tag closed cup) |
| Freezing point | -30 °C max | -42 °C | ASTM D2386 |
| Mercaptan sulfur | 0.003 % mass max | 0.00021 % mass | ASTM D3227 |
| Sulfur (No. 1-K) | 0.04 % mass max | 0.010 % mass | ASTM D2622 |
| Kinematic viscosity at 40 °C | 1.0 - 1.9 cst | 1.47 | ASTM D445 |
| API gravity @ 60 °F | 40.0 - 46.0 °API | 43.2 | ASTM D4052 (digital density meter) |
| Distillation, 90 % vol. recovered | 260 °C max | 242 °C | ASTM D86 |
| Burning quality (char value, 16 h lamp burn) | 20 mg/kg of oil burned max | 5.4 mg/kg of oil burned | ASTM D187 |
| Aromatics (FIA) | 25 % vol max | 16.6 % vol | ASTM D1319 |
Specification limits and source-record results are reproduced from the current product reference used by the TDS. This sample is not an issued certificate and does not identify a tested lot. Contact Alliance Chemical with the product and lot number for lot-specific documentation.
容器のラベルに記載されたロット番号をお知らせいただければ、無料で証明書をお送りします。