Sample Certificate of Analysis
Technical
Sample COA. Contact Alliance Chemical with your lot number to request a lot-specific COA.
Sample specification reference for Sodium Hypochlorite 10%. Source-record results are reference values, not measurements for your lot.
| Parameter | Specification | Source reference result | Test Method |
|---|---|---|---|
| Assay (NaOCl) | 10.0-11.0 wt% | 10.03 wt% | ASTM D2022 |
| Available Cl2 | 9.5-10.5 wt% | 9.6 wt% | ASTM D2022 |
| Bromate (BrO3) | 100 Max mg/L | 3.9 mg/L | FTTC 2411 |
| Excess NaOH | 0.1 - 1.2 wt% | 0.65 wt% | ASTM D2022 |
| Iron (Fe) | 2 Max mg/L | 0.17 mg/L | FTTC 2419 |
| Chlorate (as is) | 2856 ppm max | 652 ppm | — |
| Cobalt (Co) | 0.08 ppm max | 0.0080 ppm | — |
| Insolubles | 0.12 wt% max | 0.012 wt% | — |
| Copper | 0.4 ppm max | 0.037 ppm | — |
| Nickel | 0.4 ppm max | 0.049 ppm | — |
| Color/Clarity | Clear/Greenish Yellow | Passes test | — |
| Composition | 10 % sodium hypochlorite in deionized water, by weight | Conforms | By formulation; confirmed by specific gravity |
Specification limits and source-record results are reproduced from the current product reference used by the TDS. This sample is not an issued certificate and does not identify a tested lot. Contact Alliance Chemical with the product and lot number for lot-specific documentation.
容器のラベルに記載されたロット番号をお知らせいただければ、無料で証明書をお送りします。