Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

100% Ethylene Glycol Inhibited

Laboratory · 100%

CAS番号
107-21-1
Alliance Code
100-ethylene-glycol-inhibited
作成日
2026-09-11
Revision
1.2
Reviewed
2026-07-17 · Andre Taki
2D chemical structure of 100% Ethylene Glycol Inhibited
Structure · PubChem
Last reviewed 2026-07-17 by Andre Taki, DOT Hazmat Specialist.

Identity & Composition

製品名
100% Ethylene Glycol Inhibited
Alliance Code
100-ethylene-glycol-inhibited
Grade
Laboratory
濃度
100%
CAS番号
107-21-1PubChem
化学式
C2H6O2PubChem
分子量
62.07PubChem
製品種別
mixture

Specifications

TestSpecificationTypicalMethodSource
Ethylene glycol content97.8 % by volume97.8 % by volumeInterpreted
Reserve Alkalinity3 ml min.14.5Interpreted
Freeze Point-34°F max.-35°FInterpreted
Nitrite2400 ppm min.2700 ppmInterpreted
Foaming tendency (volume / break time)150 mL max / 5 s maxPasses testASTM D1881Interpreted
Chloride (as Cl)25 ppm maximum1.0 ppmASTM D3634Interpreted
Corrosion in glassware, six metalsPass — weight loss within ASTM D3306 limits for all six metalsPasses testASTM D1384Interpreted

Specification values are guaranteed limits. Typical values are representative of production lots and are not guaranteed. Lot-specific certificates of analysis ship with every order.

Physical & Chemical Properties

One or more physical-property values are temporarily suppressed pending verification against vendor COA data. For complete properties refer to the Safety Data Sheet (SDS) or contact sales@alliancechemical.com.

PropertySource
FormLiquidPublished reference
臭いOdorlessPublished reference
pH9.0 - 10.5Interpreted
Specific Gravity (20 °C)1.110-1.125Interpreted
Density1.115 at 68 °F (USCG, 1999) - Denser than water; will sinkPublished reference
沸点387.7 °F at 760 mmHg (NTP, 1992)Published reference
融点-34 °F (-36.7 °C) maximumInterpreted
引火点232 °F (NTP, 1992)Published reference
蒸気圧0.06 mmHg at 68 °F ; 1 mmHg at 127.4 °F (NTP, 1992)Published reference
Solubility (water)greater than or equal to 100 mg/mL at 63.5 °F (NTP, 1992)Published reference

Regulatory & Transport

DOT / 49 CFR

UN Number
Not regulatedAdjudicated
Hazard Class
Not regulatedAdjudicated
Packing Group
Not regulatedAdjudicated
Proper Shipping Name
Not regulatedAdjudicated

GHS / OSHA HazCom 2012

注意喚起語
WarningAdjudicated
H-Codes (Hazard Statements)
H302, H373Adjudicated
P-Codes (Precautionary Statements)
P260, P264, P270, P314, P501Adjudicated

許容濃度

OSHA PEL (29 CFR 1910.1000)
no canonical
ACGIH TLV
no canonical
NIOSH REL
no canonical
NIOSH IDLH
no canonical

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for 100% Ethylene Glycol Inhibited. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Sigma-Aldrich

SKUGradeConc.MatchNotes
293237anhydrous, 99.8%99.8%Unverified candidateSigma anhydrous; Alliance is inhibited (with corrosion inhibitor package).

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Applications

  • Anti-freezing agentlaballey.com
  • Used in the automobile industrylaballey.com
  • Manufacturing of resinslaballey.com
  • Synthesis of polyester fiberslaballey.com
  • Dehydrating agentlaballey.com
  • Polyester manufacturing and synthetic waxes productionlaballey.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
Cool, dry, well-ventilated area in tightly sealed original containers. Neat glycols are combustible liquids with high flash points (roughly 99–111 °C) and do not require a solvent store; aqueous blends will not sustain combustion. Protect inhibited coolants from contamination and from freezing below their stated protection point.Class-level guidance — not product-specific; the SDS controls.
Handling Precautions
Chemical-resistant gloves and splash goggles. Ethylene glycol grades are toxic by ingestion and must be kept away from food, drink and animals; propylene glycol grades are not. Avoid contact with hot surfaces and hot process equipment. Inhibitor packages deplete in service — monitor rather than top up blindly.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong oxidizers, strong acids and strong bases. Galvanized (zinc) surfaces are attacked by many inhibited coolant packages. Verify elastomer and gasket compatibility for the service temperature; EPDM is standard for glycol/water service.Class-level guidance — not product-specific; the SDS controls.
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

Not regulated for transport.

Confirm against shipping documents and carrier requirements before tender.

NMFC Class
55

Revision History

Last reviewed 2026-07-17 by Andre Taki, DOT Hazmat Specialist.

VersionDateChangeTrigger
1.22026-07-22Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 7 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • dotSubsidiaryHazardClass· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • signalWord· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.

100% Ethylene Glycol Inhibited — Technical Data Sheet | Alliance Chemical