Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Drain Hammer - Sulfuric Acid Drain Cleaner

Technical · 93%

Alliance Code
drain-hammer-sulfuric-acid-drain-cleaner
確認日
2026-07-17
Revision
1.7
CAS番号
7664-93-9
UN番号
UN1830
危険有害性クラス・容器等級
8 · PG II
構造
2D chemical structure of Drain Hammer - Sulfuric Acid Drain Cleaner
構造・PubChem
グレード
Technical · 93%
注意喚起語
Danger
危険有害性
腐食性H290 H314
正式輸送品名
Sulfuric acid with more than 51 percent acid
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

製品名
Drain Hammer - Sulfuric Acid Drain Cleaner
Alliance Code
drain-hammer-sulfuric-acid-drain-cleaner
グレード
Technical
濃度
93%
CAS番号
7664-93-9PubChem
化学式
—PubChem
分子量
98.08PubChem
製品種別
混合物

Specifications

Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.

物理的及び化学的性質

One or more physical-property values are temporarily suppressed pending verification against vendor COA data. For complete properties refer to the Safety Data Sheet (SDS) or contact sales@alliancechemical.com.

Property値Source
外観Colorless, oily liquidAdjudicated
形状LiquidPublished reference
臭いOdorlessPublished reference
pH1 N solution = 0.3; 0.1 N solution = 1.2; 0.01 N solution = 2.1Published reference
比重1.835Published reference
密度1.835 (93% w/w solution, 16 °C)Published reference
沸点276 °C (529 °F) (93% solution)Adjudicated
融点−29.5 °C (−21 °F) freezing point (93% solution)Adjudicated
引火点Not applicable (non-flammable)Published reference
蒸気圧1 mmHg at 294.8 °F (EPA, 1998)Published reference

Strong acid — density and vapor-pressure values shown are at 20 °C; values shift markedly with concentration and temperature. Reference concentration-temperature curves before specifying equipment.

Materials of ConstructionService envelope ≈ 93%

MOC ratings are required for this chemical class but no compatibility data has been seeded yet. Treat as no-data and consult Alliance Technical Services before equipment selection.

Regulatory & Transport

DOT / 49 CFR

国連番号
UN1830Adjudicated
危険有害性クラス
8Adjudicated
容器等級
IIAdjudicated
正式輸送品名
Sulfuric acid with more than 51 percent acidAdjudicated

GHS / OSHA HCS 2024

注意喚起語
DangerAdjudicated
H-Codes (Hazard Statements)
H290, H314Adjudicated
P-Codes (Precautionary Statements)
P234, P260, P264, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P390, P405, P406, P501Adjudicated

許容濃度

OSHA PEL (29 CFR 1910.1000)
1 mg/m³ TWAOSHA 29 CFR 1910.1000
ACGIH TLV
—no canonical
NIOSH REL
1 mg/m³ TWANIOSH Pocket Guide
NIOSH IDLH
15 mg/m³NIOSH Pocket Guide

輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Drain Hammer - Sulfuric Acid Drain Cleaner. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Sigma-Aldrich

SKUグレードConc.MatchNotes
258105ACS Reagent95-98%Unverified candidateACS Reagent 95–98%

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Application Guidance

Drain Hammer - Sulfuric Acid Drain Cleaner (Technical) is a strong mineral acid used across pH control, metal pickling, food and beverage processing, and chemical synthesis. Grade and concentration determine the appropriate end-use and materials.

  • Metal pickling, etching, and surface preparation
  • pH adjustment in water and wastewater treatment
  • Regeneration of ion-exchange resins
  • Chemical manufacturing and synthesis
  • Food and beverage processing (food-grade only)

Always add acid to water, never water to acid. Use lined or fluoropolymer piping rated for the concentration; carbon steel is not suitable for dilute acid service.

Storage & Handling

Recommended Storage
耐酸性容器に密閉し、水、塩基、有機物及び金属から離れた、涼しく乾燥した換気の良い場所で保管すること。希釈する際は、撹拌しながら水に酸をゆっくりと加えること。酸に水を絶対に加えてはならない。Adjudicated
Handling Precautions
Use full PPE including face shield, acid-resistant gloves and apron. Add acid to water slowly with stirring; never reverse. Ventilation required.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
水(発熱および飛散を伴う激しい反応);塩基;有機物および可燃性物質;還元剤;塩素酸塩、過マンガン酸塩、硝酸塩、ピクリン酸塩、雷酸塩および炭化物;シアン化物および硫化物(有毒ガスを発生);金属粉末およびほとんどの金属(可燃性水素を発生)。Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1830, Sulfuric acid with more than 51 percent acid, 8, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
60
Placard
Corrosive
容器等級
PG II

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.72026-10-13Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
canonical_change
1.62026-10-08Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-10-07Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-10-05Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-09-30Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 6 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • physicalProperties· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.