Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Ethylene Glycol 15/85

Technical · 15/85

Alliance Code
SHOPIFY-15492823941353
改訂日
2026-11-19
Revision
1.1
グレード
Technical · 15/85
注意喚起語
Warning
危険有害性
健康有害性H373
Last reviewed 2026-11-19 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

Identity & Composition

製品名
Ethylene Glycol 15/85
Alliance Code
SHOPIFY-15492823941353
グレード
Technical
濃度
15/85
製品種別
混合物

Specifications

Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.

Available GradesSame CAS, alternate grades and concentrations

グレード濃度Typical AssaySKUTDS
This grade Technical15/85—currentcurrent
Technical60% v/v—ethylene-glycol-60-40View TDS →
Technical50% v/v—ethylene-glycol-50-50View TDS →
Technical40% v/v—SHOPIFY-8019745144874View TDS →
Technical30% v/v—ethylene-glycol-30-70View TDS →
ACS Grade——ethylene-glycol-acs-gradeView TDS →

各グレードの代表的な含量は、直近ロットの平均値です。代替品として使用する前に、そのグレードがお客様の仕様を満たしていることをご確認ください。

物理的及び化学的性質

Property値Source
外観Clear, colorless to pale liquidAdjudicated
臭いMild, characteristicAdjudicated
pHEssentially neutral (unbuffered blend)Adjudicated
比重1.021 (20 °C)Adjudicated
密度1.021 g/mL at 20 °CAdjudicated
沸点~102 °CAdjudicated
融点-6 °C (freeze / crystallization onset)Adjudicated
引火点Not flammable (aqueous solution)Adjudicated
Solubility (water)Miscible with waterAdjudicated

Regulatory & Transport

DOT / 49 CFR

国連番号
非該当Adjudicated
危険有害性クラス
非該当Adjudicated
容器等級
非該当Adjudicated
正式輸送品名
非該当Adjudicated

GHS / OSHA HCS 2024

注意喚起語
WarningAdjudicated
H-Codes (Hazard Statements)
H373Adjudicated
P-Codes (Precautionary Statements)
P260, P314, P501Adjudicated

許容濃度

OSHA PEL (29 CFR 1910.1000)
—no canonical
ACGIH TLV
—no canonical
NIOSH REL
—no canonical
NIOSH IDLH
—no canonical

輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Ethylene Glycol 15/85. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Application Guidance

Ethylene Glycol 15/85 (Technical) is a glycol-based heat-transfer and freeze-protection fluid. Concentration sets the freeze and burst protection; the inhibitor package sets how long the system stays protected from corrosion.

  • Closed-loop heat transfer and process cooling
  • Data-centre and chilled-water freeze protection
  • HVAC hydronic loops and glycol makeup
  • Freeze and burst protection for idle or seasonal systems
  • Humectant and carrier applications (USP/food-grade propylene glycol only)

Verify concentration against the required freeze and burst protection, and confirm elastomer and metallurgy compatibility for the service temperature. Ethylene glycol is toxic by ingestion and must not be used where incidental food or potable contact is possible — specify a propylene glycol grade for those services.

Storage & Handling

Recommended Storage
Cool, dry, well-ventilated area in tightly sealed original containers. Neat glycols are combustible liquids with high flash points (roughly 99–111 °C) and do not require a solvent store; aqueous blends will not sustain combustion. Protect inhibited coolants from contamination and from freezing below their stated protection point.Class-level guidance — not product-specific; the SDS controls.
Handling Precautions
Chemical-resistant gloves and splash goggles. Ethylene glycol grades are toxic by ingestion and must be kept away from food, drink and animals; propylene glycol grades are not. Avoid contact with hot surfaces and hot process equipment. Inhibitor packages deplete in service — monitor rather than top up blindly.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong oxidizers, strong acids and strong bases. Galvanized (zinc) surfaces are attacked by many inhibited coolant packages. Verify elastomer and gasket compatibility for the service temperature; EPDM is standard for glycol/water service.Class-level guidance — not product-specific; the SDS controls.
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

Not regulated for transport.

Confirm against shipping documents and carrier requirements before tender.

NMFC Class
55

Revision History

Last reviewed 2026-11-19 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.12026-11-19Canonical data updated: 10 fields changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
  • signalWord· canonical change (coa.data_provenance / adjudication)
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
  • physicalProperties· canonical change (coa.data_provenance / adjudication)
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
canonical_change

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.

Ethylene Glycol 15/85 — Technical Data Sheet | Alliance Chemical