Technical Data Sheet
Semiconductor
| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Assay, monoethylene glycol | 99.5 %wt, minimum | 99.95 %wt | GC / ASTM E202 | Interpreted |
| Acidity (as acetic acid) | 20 ppm, maximum | 2 ppm | ASTM D1613 / potentiometric titration | Interpreted |
| Nonvolatile residue | 5 ppm, maximum | 1 ppm | Gravimetric, evaporation to dryness at 105 °C | Interpreted |
| Sodium (Na) | 0.05 ppm, maximum | 0.005 ppm | ICP-MS | Interpreted |
| Potassium (K) | 0.05 ppm, maximum | 0.005 ppm | ICP-MS | Interpreted |
Specification values are guaranteed limits. Typical values are representative of production lots and are not guaranteed. Lot-specific certificates of analysis ship with every order.
One or more physical-property values are temporarily suppressed pending verification against vendor COA data. For complete properties refer to the Safety Data Sheet (SDS) or contact sales@alliancechemical.com.
| Property | 値 | Source |
|---|---|---|
| Form | Liquid | Published reference |
| 臭い | Odorless | Published reference |
| Density | 1.115 at 68 °F (USCG, 1999) - Denser than water; will sink | Published reference |
| 沸点 | 387.7 °F at 760 mmHg (NTP, 1992) | Published reference |
| 融点 | 9 °F (NTP, 1992) | Published reference |
| 引火点 | 232 °F (NTP, 1992) | Published reference |
| 蒸気圧 | 0.06 mmHg at 68 °F ; 1 mmHg at 127.4 °F (NTP, 1992) | Published reference |
| Solubility (water) | greater than or equal to 100 mg/mL at 63.5 °F (NTP, 1992) | Published reference |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Ethylene Glycol Semiconductor Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Not regulated for transport.
Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-07-17 by Andre Taki, DOT Hazmat Specialist.
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.2 | 2026-07-22 | Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.1 | 2026-07-17 | Canonical data re-verified: 7 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.