Technical Data Sheet
USP Grade
| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Assay (C3H8O3, anhydrous basis) | 99.0 - 101.0 percent | 100.0 percent | USP periodate oxidation / sodium hydroxide titration (monograph Assay) | Interpreted |
| Chloride | NMT 0.001% | 0.0001 % | — | Interpreted |
| Chlorinated Compounds | NMT 0.003% of Cl | 0.0002 % | Morpholine reflux followed by silver-nitrate turbidity comparison | Interpreted |
| Diethylene Glycol | NMT 0.1% | 0.005 % | Gas chromatography with flame-ionization detection | Interpreted |
| Ethylene glycol | 0.10 Max % | 0.004 % | USP 41 (Identification Test B, gas chromatography) | Interpreted |
| Fatty Acids and Esters | NMT 1 mL of 0.5 N sodium hydroxide | 0.2 | Titration of a 50 g sample with 0.5 N sodium hydroxide and 0.5 N hydrochloric acid | Interpreted |
| Heavy Metals | NMT 5 micro-gm per g | 1 | — | Interpreted |
| Individual Impurities, excluding Diethylene Glycol | NMT 0.1% | 0.02 % | Gas chromatography with flame-ionization detection | Interpreted |
| Related compounds (any individual impurity other than diethylene glycol) | not more than 0.1% | 0.02 % | USP gas chromatography, area normalization | Interpreted |
| Related compounds (total impurities, including diethylene glycol) | not more than 1.0% | 0.05 % | USP gas chromatography, area normalization | Interpreted |
| Residue on Ignition | NMT 0.01% | 0.002 % | Ignition of a 50 g sample followed by sulfuric-acid treatment and ignition to constant weight | Interpreted |
| Sulfate | 0.002 % max | 0.0002 % | USP <221> | Interpreted |
| Total Impurities, including Diethylene Glycol | NMT 1.0% | 0.05 % | Gas chromatography with flame-ionization detection | Interpreted |
| Water | NMT 5.0% | 0.20 % | — | Interpreted |
| related compounds | 0.1 % max | 0.08 % | — | Interpreted |
Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.
| Grade | 濃度 | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade USP Grade | — | — | current | current |
| Food | 75% | — | glycerin-75-food-grade | View TDS → |
| Food | 50% | — | glycerin-50-food-grade | View TDS → |
| Food | 25% | — | glycerin-25-food-grade | View TDS → |
| Technical Grade | — | — | glycerin-technical-grade | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
| Property | 値 | Source |
|---|---|---|
| 外観 | Glycerine appears as a colorless to brown colored liquid. Combustible but may require some effort to ignite. | Published reference |
| Form | Liquid | Published reference |
| Color | 10 Max APHA | Interpreted |
| 臭い | MILD ODOR | Published reference |
| pH | 5.5-8.0 | Interpreted |
| Specific Gravity (20 °C) | 1.2612 Min | Interpreted |
| Density | 1.261 at 68 °F (USCG, 1999) - Denser than water; will sink | Published reference |
| 沸点 | 554 °F at 760 mmHg (decomposes) (NTP, 1992) | Published reference |
| 融点 | 64 °F (NTP, 1992) | Published reference |
| 引火点 | 320 °F (NTP, 1992) | Published reference |
| 蒸気圧 | 0.0025 mmHg at 122 °F ; 40 mmHg at 388 °F (NTP, 1992) | Published reference |
| Solubility (water) | greater than or equal to 100 mg/mL at 64 °F (NTP, 1992) | Published reference |
| Refractive Index (nD 20) | 1.470-1.475 | Interpreted |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Glycerin USP Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Not regulated for transport.
Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-06-17 by Andre Taki, DOT Hazmat Specialist.
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.2 | 2026-08-05 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.1 | 2026-06-17 | Canonical data re-verified: 3 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.