Inhibited Ethylene Glycol 20/80 with OAT-908 — Data Center Coolant
20% v/v
Alliance Code
SHOPIFY-7990803922986
改訂日
2026-11-16
Revision
1.11
CAS番号
107-21-1
構造
構造・PubChem
グレード
20% v/v
注意喚起語
Warning
危険有害性
健康有害性H373
Last reviewed 2026-11-16 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).
Identity & Composition
製品名
Inhibited Ethylene Glycol 20/80 with OAT-908 — Data Center Coolant
Alliance Code
SHOPIFY-7990803922986
グレード
—
濃度
20% v/v
CAS番号
107-21-1Adjudicated
化学式
C2H6O2Adjudicated
分子量
62.07Adjudicated
製品種別
混合物
Specifications
Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.
Available GradesSame CAS, alternate grades and concentrations
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Inhibited Ethylene Glycol 20/80 with OAT-908 — Data Center Coolant. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Inhibited Ethylene Glycol 20/80 with OAT-908 — Data Center Coolant is a glycol-based heat-transfer and freeze-protection fluid. Concentration sets the freeze and burst protection; the inhibitor package sets how long the system stays protected from corrosion.
Closed-loop heat transfer and process cooling
Data-centre and chilled-water freeze protection
HVAC hydronic loops and glycol makeup
Freeze and burst protection for idle or seasonal systems
Humectant and carrier applications (USP/food-grade propylene glycol only)
Verify concentration against the required freeze and burst protection, and confirm elastomer and metallurgy compatibility for the service temperature. Ethylene glycol is toxic by ingestion and must not be used where incidental food or potable contact is possible — specify a propylene glycol grade for those services.
Chemical-resistant gloves and splash goggles. Ethylene glycol grades are toxic by ingestion and must be kept away from food, drink and animals; propylene glycol grades are not. Avoid contact with hot surfaces and hot process equipment. Inhibitor packages deplete in service — monitor rather than top up blindly.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
強酸化剤、強酸および強塩基、アルデヒド類、アルカリ金属。Adjudicated