Inhibited Ethylene Glycol 40/60, Nitrite-Free — Data Center Coolant
40/60
Alliance Code
SHOPIFY-8032461324330
確認日
2026-09-23
Revision
1.1
CAS number
107-21-1
Structure
Structure · PubChem
Grade
40/60
Signal word
Warning
Hazards
Irritant / harmfulHealth hazardH302 H373
Last reviewed 2026-09-23.
Identity & Composition
製品名
Inhibited Ethylene Glycol 40/60, Nitrite-Free — Data Center Coolant
Alliance Code
SHOPIFY-8032461324330
Grade
—
濃度
40/60
CAS番号
107-21-1Adjudicated
化学式
C2H6O2Adjudicated
分子量
62.07Adjudicated
製品種別
mixture
Specifications
Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
Supplier Qualification Packet
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Inhibited Ethylene Glycol 40/60, Nitrite-Free — Data Center Coolant. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Inhibited Ethylene Glycol 40/60, Nitrite-Free — Data Center Coolant is a glycol-based heat-transfer and freeze-protection fluid. Concentration sets the freeze and burst protection; the inhibitor package sets how long the system stays protected from corrosion.
Closed-loop heat transfer and process cooling
Data-centre and chilled-water freeze protection
HVAC hydronic loops and glycol makeup
Freeze and burst protection for idle or seasonal systems
Humectant and carrier applications (USP/food-grade propylene glycol only)
Verify concentration against the required freeze and burst protection, and confirm elastomer and metallurgy compatibility for the service temperature. Ethylene glycol is toxic by ingestion and must not be used where incidental food or potable contact is possible — specify a propylene glycol grade for those services.
Storage & Handling
Recommended Storage
Cool, dry, well-ventilated area in tightly sealed original containers. Neat glycols are combustible liquids with high flash points (roughly 99–111 °C) and do not require a solvent store; aqueous blends will not sustain combustion. Protect inhibited coolants from contamination and from freezing below their stated protection point.Class-level guidance — not product-specific; the SDS controls.
Handling Precautions
Chemical-resistant gloves and splash goggles. Ethylene glycol grades are toxic by ingestion and must be kept away from food, drink and animals; propylene glycol grades are not. Avoid contact with hot surfaces and hot process equipment. Inhibitor packages deplete in service — monitor rather than top up blindly.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong oxidizers, strong acids and strong bases. Galvanized (zinc) surfaces are attacked by many inhibited coolant packages. Verify elastomer and gasket compatibility for the service temperature; EPDM is standard for glycol/water service.Class-level guidance — not product-specific; the SDS controls.
Shelf Life
Consult Technical Services for product-specific shelf life
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Packaging & Logistics
Shipping Description (US DOT)
Not regulated for transport.
Confirm against shipping documents and carrier requirements before tender.
NMFC Class
55
Revision History
Version
Date
Change
Trigger
1.1
2026-09-23
Canonical data updated: 15 fields changed via the provenance/adjudication pipeline.
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.