Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

n-Propyl Alcohol ACS Grade

ACS Grade

Alliance Code
n-propyl-alcohol-acs-grade
確認日
2026-07-17
Revision
1.6
CAS番号
71-23-8
UN番号
UN1274
危険有害性クラス・容器等級
3 · PG II
構造
2D chemical structure of n-Propyl Alcohol ACS Grade
構造・PubChem
グレード
ACS Grade
注意喚起語
Danger
危険有害性
引火性腐食性刺激性 / 有害性H225 H318 H336
正式輸送品名
n-Propanol
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

製品名
n-Propyl Alcohol ACS Grade
Alliance Code
n-propyl-alcohol-acs-grade
グレード
ACS Grade
濃度
—
CAS番号
71-23-8PubChem
化学式
C3H8OPubChem
分子量
—PubChem
製品種別
Pure substance

Specifications

TestSpecificationTypicalMethodSource
Assay (n-propyl alcohol)99.5% minimum99.96 %Gas chromatography (GC)Interpreted
Titrable Acid0.0004 meq/g max0.000097 meq/g—Interpreted
Carbonyl Compounds0.03% max0.0025 %—Interpreted
Ethyl alcohol0.01% maximum0.0009 %Gas chromatography (GC)Interpreted
Isopropyl alcohol0.05% maximum0.0040 %Gas chromatography (GC)Interpreted
Methanol0.01% max0.00047 %—Interpreted
Methyl alcohol0.01% maximum0.00047 %Gas chromatography (GC)Interpreted
Residue after evaporation0.001% maximum0.00019 %Gravimetric, evaporation to drynessInterpreted
Solubility in waterTo Pass TestPasses test—Interpreted
Water0.2% maximum0.029 %Karl FischerInterpreted
Identification (Infrared Spectrum)Conforms to structurePasses testFT-IR, comparison to reference spectrumInterpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

Available GradesSame CAS, alternate grades and concentrations

グレード濃度Typical AssaySKUTDS
This grade ACS Grade——currentcurrent
Technical——n-propyl-alcoholView TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

物理的及び化学的性質

Property値Source
外観Clear, colorless liquidAdjudicated
形状LiquidPublished reference
色10 maximumInterpreted
臭いAlcohol-like odorAdjudicated
pHAbout 7 (200 g/L aqueous solution)Adjudicated
比重0.80 at 20 °C (water = 1)Adjudicated
密度0.803 at 68 °F (USCG, 1999) - Less dense than water; will floatPublished reference
沸点97 °C (207 °F)Adjudicated
融点-127 °C (-197 °F)Adjudicated
引火点22–25 °C (72–77 °F), closed cupAdjudicated
蒸気圧15 mmHg (19–20 hPa) at 20 °CAdjudicated
Solubility (water)Completely miscible with waterAdjudicated
Refractive Index (nD 20)1.3840 - 1.3860Interpreted
粘度2.2 mm²/s at 20 °CAdjudicated

Polar solvent — purity vs. intended end-use (electronics, pharma, general industrial) is the dominant grade consideration. See application guidance for grade selection.

Materials of ConstructionService envelope ≈ 100%

MaterialRatingMax T (°C)NotesSource
Buna-N (NBR)
elastomer
Fair60Acceptable for alcohols; poor for ketones.Parker O-ring Chemical Compatibility
EPDM
elastomer
Fair—Good for alcohols, poor for estersCole-Parmer Chemical Compatibility
Viton (FKM)
elastomer
Fair80Swells in acetone and esters; avoid for those.Parker O-ring Chemical Compatibility
FFKM (Kalrez)
fluoropolymer
Excellent200Premium ester / ketone sealingCole-Parmer Chemical Compatibility
PTFE
fluoropolymer
Excellent200Universal solvent compatibility.Cole-Parmer Chemical Compatibility
Borosilicate Glass
glass ceramic
Excellent100Universally inert.Cole-Parmer Chemical Compatibility
316L Stainless Steel
metal
Excellent80Inert; preferred for high-purity solvent service.Cole-Parmer Chemical Compatibility
Aluminium
metal
Good40Acceptable; avoid prolonged wet contactCole-Parmer Chemical Compatibility
Carbon Steel
metal
Fair50Trace moisture causes rust; flash-rust prevention required.Cole-Parmer Chemical Compatibility
HDPE
thermoplastic
Fair40Swells with many polar solvents; verify per solvent.Cole-Parmer Chemical Compatibility
PP
thermoplastic
Good50Acceptable but watch swelling with estersCole-Parmer Chemical Compatibility
PVC
thermoplastic
Fair25Esters soften PVC; avoid for estersCole-Parmer Chemical Compatibility

Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.

Materials Selection Tool

Showing 12 of 12 material ratings within the selected envelope.

MaterialRatingMax T (°C)Notes
Buna-N (NBR)
elastomer
Fair60Acceptable for alcohols; poor for ketones.
EPDM
elastomer
Fair—Good for alcohols, poor for esters
Viton (FKM)
elastomer
Fair80Swells in acetone and esters; avoid for those.
FFKM (Kalrez)
fluoropolymer
Excellent200Premium ester / ketone sealing
PTFE
fluoropolymer
Excellent200Universal solvent compatibility.
Borosilicate Glass
glass ceramic
Excellent100Universally inert.
316L Stainless Steel
metal
Excellent80Inert; preferred for high-purity solvent service.
Aluminium
metal
Good40Acceptable; avoid prolonged wet contact
Carbon Steel
metal
Fair50Trace moisture causes rust; flash-rust prevention required.
HDPE
thermoplastic
Fair40Swells with many polar solvents; verify per solvent.
PP
thermoplastic
Good50Acceptable but watch swelling with esters
PVC
thermoplastic
Fair25Esters soften PVC; avoid for esters

Regulatory & Transport

DOT / 49 CFR

国連番号
UN1274Adjudicated
危険有害性クラス
3Adjudicated
容器等級
IIAdjudicated
正式輸送品名
n-PropanolAdjudicated

GHS / OSHA HCS 2024

注意喚起語
DangerAdjudicated
H-Codes (Hazard Statements)
H225, H318, H336Adjudicated
P-Codes (Precautionary Statements)
P210, P233, P240, P241, P242, P243, P261, P264, P271, P280, P303+P361+P353, P304+P340, P305+P351+P338, P310, P313, P370+P378, P403+P233, P403+P235, P405, P501Adjudicated

許容濃度

OSHA PEL (29 CFR 1910.1000)
200 ppm TWAOSHA 29 CFR 1910.1000
ACGIH TLV
—no canonical
NIOSH REL
200 ppm TWA / 250 ppm STEL, SkinAdjudicated
NIOSH IDLH
800 ppmAdjudicated

輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。

Health & Fire Hazard

Acute Toxicology

LD₅₀ Oral (rat)
1,870–8,038 mg/kg (rat); most studies above 5,000 mg/kgAdjudicated
LD₅₀ Dermal (rabbit)
4,000–4,032 mg/kgAdjudicated
LC₅₀ Inhalation (rat, 4 h)
> 20 mg/L (rat, 4 h)Adjudicated

急性毒性値はSDS第11項またはNIOSH RTECSによる。

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for n-Propyl Alcohol ACS Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Applications

  • Used in perfumes, lacquer formulation, cosmetics, dye solutions, antifreeze, soaps and window cleanersecolink.com
  • General solvent, fuel additive, degreasing agent and antifreeze componentlaballey.com
  • Industrial and domestic cleaner, DNA extraction, general solvent, and reagent in chemical manufacturelaballey.com
  • Ingredient in personal-care products, where it functions as a solvent and disinfectant.laballey.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
着火源および酸化剤から離した、換気の良い涼しい可燃性物質保管場所に容器を密閉して保管すること。施錠して保管すること。容器を接地・アース接続すること。Adjudicated
Handling Precautions
Use chemical-resistant gloves and splash goggles. Bond and ground during transfer to prevent static accumulation. Eliminate ignition sources within vapor envelope.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
強酸化剤、強酸、ハロゲン化合物、アルカリ金属。Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1274, n-Propanol, 3, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
70
Placard
Flammable Liquid
容器等級
PG II

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.62026-10-08Canonical data updated: 22 fields changed via the provenance/adjudication pipeline.
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • restrictions_on_use· canonical change (coa.data_provenance / adjudication)
  • odor· canonical change (coa.data_provenance / adjudication)
  • pH· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • specificGravity· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • viscosity· canonical change (coa.data_provenance / adjudication)
  • explosiveLimits· canonical change (coa.data_provenance / adjudication)
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
  • dot_transport_note· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-10-07Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-10-05Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
  • oel_osha_pel· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-09-30Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 5 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.