Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Perchloroethylene (PCE, PERC)

Technical

Alliance Code
perchloroethylene-pce-perc
確認日
2026-07-17
Revision
1.9
CAS番号
127-18-4
UN番号
UN1897
危険有害性クラス・容器等級
6.1 · PG III
構造
2D chemical structure of Perchloroethylene (PCE, PERC)
構造・PubChem
グレード
Technical
注意喚起語
Danger
危険有害性
刺激性 / 有害性健康有害性環境に対する有害性H315 H317 H319 H336 H350 H370 H373 H411
正式輸送品名
Tetrachloroethylene
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

製品名
Perchloroethylene (PCE, PERC)
Alliance Code
perchloroethylene-pce-perc
グレード
Technical
濃度
—
CAS番号
127-18-4PubChem
化学式
C2Cl4PubChem
分子量
—PubChem
製品種別
Pure substance

Specifications

TestSpecificationTypicalMethodSource
Assay (Perchloroethylene, stabilizer-free basis)99.9 % by weight min.99.96 % by weight—Interpreted
Acid acceptance (as NaOH)0.20 % by weight min.0.28 % by weight—Interpreted
Distillation range120.0 - 122.0 °C120.9 °C—Interpreted
Soluble chloride1.0 ppm max.0.07 ppm—Interpreted
Color15 Pt-Co max.8—Interpreted
Copper corrosionPasses TestPasses test—Interpreted
Free chlorineNonePasses test—Interpreted
Free halogensPasses TestPasses testASTM D 4755Interpreted
Acidity-Alkalinity (pH)8.0 - 9.0 pH8.6—Interpreted
Non-volatile residue25 ppm max.3.4 ppm—Interpreted
Spot or cleanlinessNo spot or stainPasses test—Interpreted
Water (H2O)30 ppm max.15 ppm—Interpreted
stabilizer as nh30.00006 - 0.002 %0.00102 %—Interpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

物理的及び化学的性質

Property値Source
外観Colorless liquid with a mild, sweet odorAdjudicated
形状LiquidPublished reference
臭いCharacteristic ethereal, no foreign odorInterpreted
比重1.62 at 25 °C (water = 1); sinks in waterAdjudicated
密度1.63 at 68 °F (USCG, 1999) - Denser than water; will sinkPublished reference
沸点121 °C (250 °F) at 760 mmHgAdjudicated
融点-22 to -19 °C (-8 to -2 °F)Adjudicated
引火点No flash point in conventional closed tester.Published reference
蒸気圧13–14 mmHg (1.7–1.8 kPa) at 20 °CAdjudicated
蒸気密度5.8 (air = 1)Adjudicated
Solubility (water)0.15 g/L in water at 20 °C (practically insoluble)Adjudicated
粘度0.89 mPa·s at 20 °CAdjudicated

Materials of Construction

MaterialRatingConditionsSource
stainless steelCompatibleneat perchloroethylene as shipped in bulk; source states no concentration or temperature limitoxychem.com

Compatibility is drawn from published manufacturer and supplier documentation for this product; each rating is sourced. Confirm against your specific duty cycle before equipment selection.

Regulatory & Transport

DOT / 49 CFR

国連番号
UN1897Adjudicated
危険有害性クラス
6.1Adjudicated
容器等級
IIIAdjudicated
正式輸送品名
TetrachloroethyleneAdjudicated

GHS / OSHA HCS 2024

注意喚起語
DangerAdjudicated
H-Codes (Hazard Statements)
H315, H317, H319, H336, H350, H370, H373, H411Adjudicated
P-Codes (Precautionary Statements)
P201, P202, P260, P264, P270, P272, P273, P280, P302+P352, P305+P351+P338, P308+P311, P308+P313, P312, P314, P321, P332+P313, P333+P313, P337+P313, P362, P391, P405, P501Adjudicated

許容濃度

OSHA PEL (29 CFR 1910.1000)
100 ppm TWA / 200 ppm acceptable ceiling / 300 ppm 5-min peakOSHA 29 CFR 1910.1000
ACGIH TLV
25 ppm TWA / 100 ppm STEL (A3: confirmed animal carcinogen)Adjudicated
NIOSH REL
Ca (carcinogen — minimize occupational exposure)NIOSH Pocket Guide
NIOSH IDLH
150 ppmNIOSH Pocket Guide

輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。

Health & Fire Hazard

Acute Toxicology

LD₅₀ Oral (rat)
2,629 mg/kgAdjudicated
LD₅₀ Dermal (rabbit)
> 3,228 mg/kgAdjudicated
LC₅₀ Inhalation (rat, 4 h)
27.8 mg/L (vapor)Adjudicated

急性毒性値はSDS第11項またはNIOSH RTECSによる。

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Perchloroethylene (PCE, PERC). Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Applications

  • Supplied as an all-purpose / degreasing solvent grade of perchloroethylenewestlake.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
容器を密閉し、直射日光及び湿気を避け、涼しく乾燥した換気の良い場所に保管すること。アルミニウム製の容器で保管しないこと。強塩基、活性金属および酸化剤から遠ざけること。施錠して保管すること。Adjudicated
Handling Precautions
Use standard chemical PPE — splash goggles, gloves, lab coat. Refer to SDS for hazard-specific PPE requirements.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
強酸化剤、強酸および強塩基、反応性の高い微粉末金属(アルミニウム、亜鉛、アルカリ金属)、アミン類、過酸化物、酸素。Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1897, Tetrachloroethylene, 6.1, PG III

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
70
Placard
Toxic
容器等級
PG III

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.92026-10-13Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
canonical_change
1.82026-10-08Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.72026-10-07Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.62026-10-06Canonical data updated: 20 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • vaporDensity· canonical change (coa.data_provenance / adjudication)
  • specificGravity· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • viscosity· canonical change (coa.data_provenance / adjudication)
  • partitionCoefficient· canonical change (coa.data_provenance / adjudication)
  • oel_acgih_tlv· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
  • dot_transport_note· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-10-05Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • restrictions_on_use· canonical change (coa.data_provenance / adjudication)
  • tsca_section6_notice· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-09-30Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-17Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
  • signalWord· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 6 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • signalWord· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.