Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

pH-Ree Fall - World Class Buffering Solution For PH Stability Made From Phosphoric Acid Technical Grade

Technical · 30%

Alliance Code
ph-ree-fall-world-class-buffering-solution-for-ph-stability-made-from-phosphoric-acid
確認日
2026-07-17
Revision
1.6
CAS番号
7664-38-2
UN番号
UN1805
危険有害性クラス・容器等級
8 · PG III
構造
2D chemical structure of pH-Ree Fall - World Class Buffering Solution For PH Stability Made From Phosphoric Acid Technical Grade
構造・PubChem
グレード
Technical · 30%
注意喚起語
Danger
危険有害性
腐食性H290 H314
正式輸送品名
Phosphoric acid solution
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

製品名
pH-Ree Fall - World Class Buffering Solution For PH Stability Made From Phosphoric Acid Technical Grade
Alliance Code
ph-ree-fall-world-class-buffering-solution-for-ph-stability-made-from-phosphoric-acid
グレード
Technical
濃度
30%
CAS番号
7664-38-2PubChem
化学式
—PubChem
分子量
—PubChem
製品種別
Solution

Specifications

Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.

物理的及び化学的性質

Property値Source
外観Clear, colorless liquidAdjudicated
形状LiquidPublished reference
臭いOdorlessPublished reference
pHpH = 1.5 (0.1 N aqueous solution)Published reference
密度≈1.18 (30% w/w aqueous solution, 20 °C)Published reference
沸点Not characterized for the 30% aqueous solution (water-dominated, ~100 °C)Adjudicated
融点Not characterized for the 30% aqueous solutionPublished reference
蒸気圧Not characterized for the 30% aqueous solution (water-dominated)Published reference
Solubility (water)Miscible (NIOSH, 2024)Published reference

Strong acid — density and vapor-pressure values shown are at 20 °C; values shift markedly with concentration and temperature. Reference concentration-temperature curves before specifying equipment.

Materials of ConstructionService envelope ≈ 30%

MOC ratings are required for this chemical class but no compatibility data has been seeded yet. Treat as no-data and consult Alliance Technical Services before equipment selection.

Regulatory & Transport

DOT / 49 CFR

国連番号
UN1805Adjudicated
危険有害性クラス
8Adjudicated
容器等級
IIIAdjudicated
正式輸送品名
Phosphoric acid solutionAdjudicated

GHS / OSHA HCS 2024

注意喚起語
DangerAdjudicated
H-Codes (Hazard Statements)
H290, H314Adjudicated
P-Codes (Precautionary Statements)
P234, P260, P264, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P390, P405, P406, P501Adjudicated

許容濃度

OSHA PEL (29 CFR 1910.1000)
1 mg/m³ TWAOSHA 29 CFR 1910.1000
ACGIH TLV
—no canonical
NIOSH REL
1 mg/m³ TWA / 3 mg/m³ STELNIOSH Pocket Guide
NIOSH IDLH
1000 mg/m³NIOSH Pocket Guide

輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for pH-Ree Fall - World Class Buffering Solution For PH Stability Made From Phosphoric Acid Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Sigma-Aldrich

SKUグレードConc.MatchNotes
345245ACS Reagent85%Unverified candidateACS Reagent ≥85%

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Application Guidance

pH-Ree Fall - World Class Buffering Solution For PH Stability Made From Phosphoric Acid Technical Grade (Technical) is a strong mineral acid used across pH control, metal pickling, food and beverage processing, and chemical synthesis. Grade and concentration determine the appropriate end-use and materials.

  • Metal pickling, etching, and surface preparation
  • pH adjustment in water and wastewater treatment
  • Regeneration of ion-exchange resins
  • Chemical manufacturing and synthesis
  • Food and beverage processing (food-grade only)

Always add acid to water, never water to acid. Use lined or fluoropolymer piping rated for the concentration; carbon steel is not suitable for dilute acid service.

Storage & Handling

Recommended Storage
塩基、漂白剤および金属から離し、軟鋼ではなくポリエチレンまたはその他の耐酸性容器に密閉して保管すること。Adjudicated
Handling Precautions
Use full PPE including face shield, acid-resistant gloves and apron. Add acid to water slowly with stirring; never reverse. Ventilation required.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
強塩基(激しい反応)、漂白剤およびその他の次亜塩素酸塩(塩素を発生)およびアンモニア、ほとんどの金属(可燃性の水素を発生)、硫化物、亜硫酸塩およびシアン化物(有毒ガスを発生)。Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1805, Phosphoric acid solution, 8, PG III

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
65
Placard
Corrosive
容器等級
PG III

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.62026-10-13Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-10-07Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-10-05Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • oel_osha_pel· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-09-30Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 5 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • physicalProperties· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.