Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Potassium Hydroxide (KOH) Technical Grade

Technical · 90.3%

Alliance Code
potassium-hydroxide-flakes-koh
確認日
2026-06-18
Revision
1.3
CAS number
1310-58-3
UN number
UN1813
Hazard class · packing group
8 · PG II
Structure
2D chemical structure of Potassium Hydroxide (KOH) Technical Grade
Structure · PubChem
Grade
Technical · 90.3%
Signal word
Danger
Hazards
CorrosiveIrritant / harmfulH290 H302 H314
Proper shipping name
Potassium Hydroxide, solid
Last reviewed 2026-06-18 by Andre Taki, Chief Commercial Officer.

Identity & Composition

製品名
Potassium Hydroxide (KOH) Technical Grade
Alliance Code
potassium-hydroxide-flakes-koh
Grade
Technical
濃度
90.3%
CAS番号
1310-58-3PubChem
化学式
PubChem
分子量
PubChem
製品種別
pure_substance

Specifications

TestSpecificationTypicalMethodSource
Assay90%90%Acidimetric titration (Acidim.)Interpreted
Hydroxide alkalinity as KOH (wt. %)90 min90.8 wt %Interpreted
Arsenic (As)0.0003 %0.00001 %Interpreted
Potassium chloride as KCl (ppm by wt.)150 max36 ppmInterpreted
Heavy metals (as Pb)≤0.002%0.0001 %Interpreted
Iron as Fe (ppm by wt.)3 max1.2 ppmInterpreted
Lead (Pb)0.005 %0.00001 %Interpreted
Nickel as Ni (ppm by wt.)4 max1.5 ppmInterpreted
Potassium carbonate as K2CO3 (wt. %)0.44 max0.30 wt %Interpreted
Potassium Carbonate (K2CO3)≤1.0%0.30 %Interpreted
Sulfate (SO4)0.05%0.0003 %Interpreted
Insoluble matter in H2O0.05 %0.001 %Interpreted
Sodium (as Na)0.5% Max.0.24 %Flame AAS / ICP-OESInterpreted
carbonate as k2co30.5 wt % max0.30 wt %Interpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

Physical & Chemical Properties

One or more physical-property values are temporarily suppressed pending verification against vendor COA data. For complete properties refer to the Safety Data Sheet (SDS) or contact sales@alliancechemical.com.

PropertySource
FormSolidPublished reference
臭いOdorlessPublished reference
Density1.45 to 1.50 at 68 °F (USCG, 1999)Published reference
沸点greater than 266 °F at 760 mmHg (USCG, 1999)Published reference
融点680 °F approximately (NTP, 1992)Published reference
引火点N/APublished reference
蒸気圧1 mmHg at 1326 °F ; 5 mmHg at 1497 °F (NTP, 1992)Published reference
Solubility (water)107 g/100 cc at 59 °F (NTP, 1992)Published reference

Strong base — hygroscopic; values may drift in opened containers. See storage guidance.

Materials of ConstructionService envelope ≈ 90.3%

MaterialRatingMax T (°C)NotesSource
Buna-N (NBR)
elastomer
Fair40Limited service lifeCole-Parmer Chemical Compatibility
EPDM
elastomer
Excellent90Preferred elastomerCole-Parmer Chemical Compatibility
Viton (FKM)
elastomer
PoorNot recommended above 25%Cole-Parmer Chemical Compatibility
PTFE
fluoropolymer
Excellent200Universal compatibility.Cole-Parmer Chemical Compatibility
304 stainless steel
metal
Good80Acceptable for dilute causticCole-Parmer Chemical Compatibility
316 stainless steel
metal
Excellent95Standard caustic serviceCole-Parmer Chemical Compatibility
Aluminium
metal
Not recommendedRapid attack; generates hydrogenCole-Parmer Chemical Compatibility
Carbon steel
metal
Good50Acceptable to 50 °C; caustic embrittlement aboveCole-Parmer Chemical Compatibility
Nickel
metal
Excellent100Preferred for high-temperature causticCole-Parmer Chemical Compatibility
Zinc / galvanized steel
metal
Not recommendedRapid corrosionCole-Parmer Chemical Compatibility
HDPE
thermoplastic
Excellent60Standard drum / IBC materialCole-Parmer Chemical Compatibility
PP
thermoplastic
Excellent80Preferred for elevated temperatureCole-Parmer Chemical Compatibility
PVC
thermoplastic
Good40Acceptable for ambient serviceCole-Parmer Chemical Compatibility

Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.

Materials Selection Tool

Showing 13 of 13 material ratings within the selected envelope.

MaterialRatingMax T (°C)Notes
Buna-N (NBR)
elastomer
Fair40Limited service life
EPDM
elastomer
Excellent90Preferred elastomer
Viton (FKM)
elastomer
PoorNot recommended above 25%
PTFE
fluoropolymer
Excellent200Universal compatibility.
304 stainless steel
metal
Good80Acceptable for dilute caustic
316 stainless steel
metal
Excellent95Standard caustic service
Aluminium
metal
Not recommendedRapid attack; generates hydrogen
Carbon steel
metal
Good50Acceptable to 50 °C; caustic embrittlement above
Nickel
metal
Excellent100Preferred for high-temperature caustic
Zinc / galvanized steel
metal
Not recommendedRapid corrosion
HDPE
thermoplastic
Excellent60Standard drum / IBC material
PP
thermoplastic
Excellent80Preferred for elevated temperature
PVC
thermoplastic
Good40Acceptable for ambient service

Regulatory & Transport

DOT / 49 CFR

UN Number
UN181349 CFR 172.101
Hazard Class
8Adjudicated
Packing Group
IIAdjudicated
Proper Shipping Name
Potassium Hydroxide, solidAdjudicated

GHS / OSHA HazCom 2012

注意喚起語
DangerAdjudicated
H-Codes (Hazard Statements)
H290, H302, H314ECHA CLP Annex VI
P-Codes (Precautionary Statements)
P234, P260, P264, P270, P280, P301+P312+P330, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P405, P501ECHA CLP Annex VI

許容濃度

OSHA PEL (29 CFR 1910.1000)
no canonical
ACGIH TLV
no canonical
NIOSH REL
2 mg/m³ ceilingNIOSH Pocket Guide
NIOSH IDLH
no canonical

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Potassium Hydroxide (KOH) Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Applications

  • Industrial uses of potassium hydroxide: detergents/soaps, dyeing and bleaching, paint and varnish removers, electroplating, photo engraving, lithography, alkaline batteries, analytical chemistry, fuel and gas, thickening agent, organic synthesis, stabilizercorecheminc.com
  • Used in a large number of manufacturing processesstore.astm.org

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
Store at room temperature; the material is deliquescent and absorbs CO2 and moisture from the air, and the supplier's precautionary phrases include P405 (store locked up).itwreagents.com
Handling Precautions
Use full PPE including chemical splash goggles and alkali-resistant gloves. Add base to water slowly with stirring. Highly exothermic dilution.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Acids (violent neutralization), aluminium, zinc, tin (generates hydrogen gas), halogens, organic nitro compounds.Class-level guidance — not product-specific; the SDS controls.
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1813, Potassium Hydroxide, solid, 8, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
60
Placard
Corrosive
Packing Group
PG II

Revision History

Last reviewed 2026-06-18 by Andre Taki, DOT Hazmat Specialist.

VersionDateChangeTrigger
1.32026-08-05Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-06-18Canonical data re-verified: 3 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.