Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Sulfuric Acid 96% ACS Grade

ACS Grade · 96%

Alliance Code
sulfuric-acid-96-acs-grade
確認日
2026-07-17
Revision
1.8
CAS番号
7664-93-9
UN番号
UN1830
危険有害性クラス・容器等級
8 · PG II
構造
2D chemical structure of Sulfuric Acid 96% ACS Grade
構造・PubChem
グレード
ACS Grade · 96%
注意喚起語
Danger
危険有害性
腐食性刺激性 / 有害性H290 H314 H335
正式輸送品名
Sulfuric acid with more than 51 percent acid
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

製品名
Sulfuric Acid 96% ACS Grade
Alliance Code
sulfuric-acid-96-acs-grade
グレード
ACS Grade
濃度
96%
CAS番号
7664-93-9PubChem
化学式
—PubChem
分子量
98.08PubChem
製品種別
Solution

Specifications

TestSpecificationTypicalMethodSource
Assay (H2SO4)95.0 to 98.0 %95.7 %Titration with NaOHInterpreted
Ammonium (NH4)2 ppm max0.21 ppm—Interpreted
Arsenic (As)0.01 ppm max.0.0019 ppm—Interpreted
Chloride (Cl)0.2 ppm max.0.048 ppm—Interpreted
Color, APHA10 max.6—Interpreted
Heavy Metals (as Pb)1 ppm max.0.08 ppm—Interpreted
Iron (Fe)=<0.2 ppm0.050 ppm—Interpreted
Mercury (Hg)< 5 ppb max.0.17 ppb—Interpreted
Nitrate (NO3)0.5 ppm max0.12 ppm—Interpreted
Substances Reducing Permanganate (as SO2)2 ppm max.0.32 ppm—Interpreted
Residue after Ignition5 ppm max.0.9 ppm—Interpreted
Selenium (Se)0.02 ppm max.0.0044 ppmHydride generation AAS / ICP-MSInterpreted
0.1 µm750 pcs/ml max47—Interpreted
aluminum0.1 ppb max< 0.1—Interpreted
antimony0.1 ppb max< 0.1—Interpreted
barium0.1 ppb max< 0.1—Interpreted
beryllium0.1 ppb max< 0.1—Interpreted
bismuth0.1 ppb max< 0.1—Interpreted
boron0.1 ppb max< 0.1—Interpreted
cadmium0.1 ppb max< 0.1—Interpreted
calcium0.1 ppb max< 0.1—Interpreted
chromium0.1 ppb max< 0.1—Interpreted
cobalt0.1 ppb max< 0.1—Interpreted
copper0.1 ppb max< 0.1—Interpreted
gallium0.1 ppb max< 0.1—Interpreted
germanium0.1 ppb max< 0.1—Interpreted
gold0.1 ppb max< 0.1—Interpreted
lead0.1 ppb max< 0.1—Interpreted
lithium0.1 ppb max< 0.1—Interpreted
magnesium0.1 ppb max< 0.1—Interpreted
manganese0.1 ppb max< 0.1—Interpreted
molybdenum0.1 ppb max< 0.1—Interpreted
nickel0.1 ppb max< 0.1—Interpreted
niobium0.1 ppb max< 0.1—Interpreted
phosphate100 ppb max< 100—Interpreted
potassium0.1 ppb max< 0.1—Interpreted
silver0.1 ppb max< 0.1—Interpreted
sodium0.1 ppb max< 0.1—Interpreted
strontium0.1 ppb max< 0.1—Interpreted
tantalum0.1 ppb max< 0.1—Interpreted
thallium0.1 ppb max< 0.1—Interpreted
tin0.1 ppb max< 0.1—Interpreted
titanium0.1 ppb max< 0.1—Interpreted
vanadium0.1 ppb max< 0.1—Interpreted
zinc0.1 ppb max< 0.1—Interpreted
zirconium0.1 ppb max< 0.1—Interpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

Available GradesSame CAS, alternate grades and concentrations

グレード濃度Typical AssaySKUTDS
This grade ACS Grade96%—currentcurrent
Technical Grade93%—sulfuric-acid-93-technical-gradeView TDS →
Technical70%—sulfuric-acid-70View TDS →
—50%—sulfuric-acid-50-electrolyte-gradeView TDS →
—37%—sulfuric-acid-37-battery-acidView TDS →
Technical30%—sulfuric-acid-30View TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

物理的及び化学的性質

Property値Source
外観Dense, clear liquidAdjudicated
形状LiquidPublished reference
臭いOdorlessPublished reference
pH< 1Adjudicated
比重1.84 at 20 °C (water = 1)Adjudicated
密度1.841 (EPA, 1998) - Denser than water; will sinkPublished reference
沸点295–315 °C (563–599 °F)Adjudicated
融点-15 °C (5 °F)Adjudicated
引火点N/APublished reference
蒸気圧< 0.01 hPa at 20 °CAdjudicated
蒸気密度3.4 (air = 1)Adjudicated
Solubility (water)Miscible with water, releasing intense heat. Always add acid slowly to water, never water to acid.Adjudicated
粘度26.9 mPa·s at 20 °CAdjudicated

Strong acid — density and vapor-pressure values shown are at 20 °C; values shift markedly with concentration and temperature. Reference concentration-temperature curves before specifying equipment.

Materials of ConstructionService envelope ≈ 96%

MOC ratings are required for this chemical class but no compatibility data has been seeded yet. Treat as no-data and consult Alliance Technical Services before equipment selection.

Regulatory & Transport

DOT / 49 CFR

国連番号
UN183049 CFR 172.101
危険有害性クラス
8Adjudicated
容器等級
IIAdjudicated
正式輸送品名
Sulfuric acid with more than 51 percent acidAdjudicated

GHS / OSHA HCS 2024

注意喚起語
DangerAdjudicated
H-Codes (Hazard Statements)
H290, H314, H335Adjudicated
P-Codes (Precautionary Statements)
P234, P260, P261, P264, P271, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P390, P403+P233, P405, P406, P501Adjudicated

許容濃度

OSHA PEL (29 CFR 1910.1000)
1 mg/m³ TWAOSHA 29 CFR 1910.1000
ACGIH TLV
0.2 mg/m³ TWA (thoracic fraction); A2 for strong inorganic acid mists containing sulfuric acidAdjudicated
NIOSH REL
1 mg/m³ TWANIOSH Pocket Guide
NIOSH IDLH
15 mg/m³NIOSH Pocket Guide

輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。

Health & Fire Hazard

Acute Toxicology

LD₅₀ Oral (rat)
2,140 mg/kgAdjudicated
LC₅₀ Inhalation (rat, 4 h)
0.375 mg/L (mist)Adjudicated

急性毒性値はSDS第11項またはNIOSH RTECSによる。

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Sulfuric Acid 96% ACS Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Sigma-Aldrich

SKUグレードConc.MatchNotes
258105ACS Reagent95-98%Unverified candidateACS Reagent 95–98%

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Applications

  • Oxidizing and dehydrating agent in chemical processinglookpolymers.com
  • Treatment of metals (metallurgy) and purification of petroleumlookpolymers.com
  • pH control in water treatmentlookpolymers.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
耐酸性容器に密閉し、水、塩基、有機物及び金属から離れた、涼しく乾燥した換気の良い場所で保管すること。希釈する際は、撹拌しながら水に酸をゆっくりと加えること。酸に水を絶対に加えてはならない。Adjudicated
Handling Precautions
Use full PPE including face shield, acid-resistant gloves and apron. Add acid to water slowly with stirring; never reverse. Ventilation required.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
水(発熱および飛散を伴う激しい反応);塩基;有機物および可燃性物質;還元剤;塩素酸塩、過マンガン酸塩、硝酸塩、ピクリン酸塩、雷酸塩および炭化物;シアン化物および硫化物(有毒ガスを発生);金属粉末およびほとんどの金属(可燃性水素を発生)。Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1830, Sulfuric acid with more than 51 percent acid, 8, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
60
Placard
Corrosive
容器等級
PG II

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.82026-10-12Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • dot_transport_note· canonical change (coa.data_provenance / adjudication)
canonical_change
1.72026-10-07Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.62026-10-06Canonical data updated: 22 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
  • vaporDensity· canonical change (coa.data_provenance / adjudication)
  • pH· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • oel_acgih_tlv· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • specificGravity· canonical change (coa.data_provenance / adjudication)
  • viscosity· canonical change (coa.data_provenance / adjudication)
  • decompositionTemperature· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
  • dot_transport_note· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-10-05Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-09-30Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-08-05Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 4 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.