Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Toluene

Reagent

Alliance Code
toluene
確認日
2026-06-18
Revision
1.7
CAS番号
108-88-3
UN番号
UN1294
危険有害性クラス・容器等級
3 · PG II
構造
2D chemical structure of Toluene
構造・PubChem
グレード
Reagent
注意喚起語
Danger
危険有害性
引火性刺激性 / 有害性健康有害性H225 H304 H315 H336 H361d H373 H412
正式輸送品名
Toluene
Last reviewed 2026-06-18 by Andre Taki, Chief Commercial Officer.

Identity & Composition

製品名
Toluene
Alliance Code
toluene
グレード
Reagent
濃度
—
CAS番号
108-88-3PubChem
化学式
C7H8PubChem
分子量
92.14PubChem
製品種別
Pure substance

Specifications

TestSpecificationTypicalMethodSource
Assay (Toluene)99.5% Minimum99.85 %—Interpreted
Acidity / NeutralityNeutral (mg NaOH/100 ml)Passes testASTM D 847Interpreted
BenzeneMax 0.100 Wt %0.014 Wt %ASTM D2360Interpreted
Distillation Range (IBP to DP)1 °C max including 110.6 °CPasses testASTM D 850Interpreted
Acid Wash ColorMax 21ASTM D848Interpreted
Color (Pt-Co)Max 205ASTM D1209Interpreted
Copper CorrosionPass (1A or 1B)Passes testASTM D849Interpreted
H2S / SO2Not DetectablePasses test—Interpreted
Nitration Grade Toluene conformanceMeets StandardPasses testASTM D841Interpreted
Non-aromaticsMax 1.5 Vol %0.061 Vol %ASTM D2360Interpreted
Residue after evaporation=<0.001 %0.00024 %—Interpreted
Sulfur compounds (as S)=<0.003 %0.000074 %—Interpreted
Water=<0.03 %0.008 %CoulometricInterpreted
C8 and heavier aromatics (GC)Max 0.05 Wt %0.008 Wt %ASTM D5917 / capillary GCInterpreted
Flash point, closed cupMin 4 °C (39 °F)5.0 °C (41 °F)ASTM D56 (Tag closed cup)Interpreted
c8aromatics0.5 % weight max0.0072—Interpreted
dry point233 °F (111.7 °C) max231.1 (110.6)—Interpreted
initial point229 °F (109.4 °C) min230 (110)—Interpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

物理的及び化学的性質

One or more physical-property values are temporarily suppressed pending verification against vendor COA data. For complete properties refer to the Safety Data Sheet (SDS) or contact sales@alliancechemical.com.

Property値Source
外観Clear, mobile liquidAdjudicated
形状LiquidPublished reference
臭いSweet, aromatic (benzene-like) odorAdjudicated
比重0.87 at 20 °C (water = 1)Adjudicated
密度0.867 at 68 °F (USCG, 1999) - Less dense than water; will floatPublished reference
沸点110–111 °C (230–232 °F) at 760 mmHgAdjudicated
融点-95 °C (-139 °F)Adjudicated
引火点4 °C (39 °F), closed cupAdjudicated
蒸気圧29 hPa (22 mmHg) at 20 °CAdjudicated
蒸気密度3.1 (air = 1)Adjudicated
Solubility (water)Practically insoluble in water (0.5 g/L at 20 °C)Adjudicated
Refractive Index (nD 20)1.4919 - 1.4983Interpreted
粘度0.6 mPa·s at 20 °CAdjudicated

Materials of Construction

MaterialRatingConditionsSource
mild steel (MS) drumCompatiblepure, nitration grade toluene, min 98.8 wt% purity; 172 kg fill in used MS drumscredencechemplast.com
metal pail / metal drumCompatibletechnical grade toluene, assay 99.5% minimum, as supplied by the manufacturer in 1 gal, 5 gal and 55 gal containersrmreagents.com
copperCompatibleASTM D849 copper strip corrosion test, pass 1A or 1B; toluene min 98.50 wt% puritywamlgroup.lk

Compatibility is drawn from published manufacturer and supplier documentation for this product; each rating is sourced. Confirm against your specific duty cycle before equipment selection.

Regulatory & Transport

DOT / 49 CFR

国連番号
UN129449 CFR 172.101
危険有害性クラス
3Adjudicated
容器等級
IIAdjudicated
正式輸送品名
TolueneAdjudicated

GHS / OSHA HCS 2024

注意喚起語
DangerAdjudicated
H-Codes (Hazard Statements)
H225, H304, H315, H336, H361d, H373, H412ECHA C&L Inventory
P-Codes (Precautionary Statements)
P201, P202, P210, P233, P240, P241, P242, P243, P260, P261, P264, P270, P271, P273, P280, P301+P310, P302+P352, P303+P361+P353, P304+P340, P308+P313, P312, P314, P321, P331, P332+P313, P362, P370+P378, P403+P233, P403+P235, P405, P501ECHA C&L Inventory

許容濃度

OSHA PEL (29 CFR 1910.1000)
200 ppm TWA / 300 ppm acceptable ceiling / 500 ppm 10-min peakOSHA 29 CFR 1910.1000
ACGIH TLV
20 ppm TWAAdjudicated
NIOSH REL
100 ppm TWA / 150 ppm STELNIOSH Pocket Guide
NIOSH IDLH
500 ppmNIOSH Pocket Guide

輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。

Health & Fire Hazard

Acute Toxicology

LD₅₀ Oral (rat)
> 5,000 mg/kgAdjudicated
LD₅₀ Dermal (rabbit)
12,000–14,100 mg/kgAdjudicated
LC₅₀ Inhalation (rat, 4 h)
12.5–28.8 mg/L (vapor)Adjudicated

急性毒性値はSDS第11項またはNIOSH RTECSによる。

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Toluene. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Sigma-Aldrich

SKUグレードConc.MatchNotes
244511ACS Reagent99.9%Unverified candidateACS Reagent ≥99.9%

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Applications

  • Industrial solvent for dissolving paints, coatings, adhesives and resins in manufacturing and chemical processingrmreagents.com
  • Feedstock and processing solvent in chemical manufacturing; degreasing and cleaning of metal surfaces; solvent for printing inks and dyesrmreagents.com
  • Raw material for producing benzene, xylenes, toluene diisocyanate (TDI), TNT, phenol and caprolactamwamlgroup.lk
  • Solvent in nitrocellulose lacquers, varnish, paints and enamels, and in adhesive and printing ink manufacturewamlgroup.lk
  • Octane booster in gasoline; solvent for synthetic resin and PVCwamlgroup.lk
  • High-solvency aromatic fluid for adhesives, coatings, roofing, cleaning and printing formulationsexxonmobilchemical.com
  • Used in the manufacture of adhesives and printing inks.wamlgroup.lk
  • Used as a solvent for synthetic resin and PVC.wamlgroup.lk

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
容器を密閉し、熱、火花、裸火および直射日光を避け、涼しく乾燥した換気の良い可燃物保管場所に保管すること。酸化剤、強酸および強塩基から離し、隔離された可燃物エリアに施錠して保管すること。開封した容器は慎重に再密閉し、直立させた状態で保管すること。移送・移注時には容器を接地(アース・ボンディング)すること。Adjudicated
Handling Precautions
Eliminate ignition sources. Use chemical-resistant nitrile or PVA gloves. Bond and ground all transfer equipment. Vapors heavier than air — control ventilation accordingly.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
強酸化剤(硝酸、過酸化物、過塩素酸塩)、強酸及び強塩基、ハロゲン及びハロゲン化化合物。Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1294, Toluene, 3, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
70
Placard
Flammable Liquid
容器等級
PG II

Revision History

Last reviewed 2026-06-18 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.72026-10-13Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
canonical_change
1.62026-10-07Canonical data updated: 23 fields changed via the provenance/adjudication pipeline.
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
  • restrictions_on_use· canonical change (coa.data_provenance / adjudication)
  • odor· canonical change (coa.data_provenance / adjudication)
  • odorThreshold· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • vaporDensity· canonical change (coa.data_provenance / adjudication)
  • specificGravity· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • viscosity· canonical change (coa.data_provenance / adjudication)
  • evaporationRate· canonical change (coa.data_provenance / adjudication)
  • explosiveLimits· canonical change (coa.data_provenance / adjudication)
  • oel_acgih_tlv· canonical change (coa.data_provenance / adjudication)
  • oel_other· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
  • dot_transport_note· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-09-30Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-08-09Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-08-05Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-06-18Canonical data re-verified: 4 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • boilingPoint· canonical adjudication / reground (coa.data_provenance)
  • color· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • specificGravity· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.