Industrial chemicals · Taylor, TX
Safety Data Sheet

Safety Data Sheet · OSHA HCS 2024

Diesel Exhaust Fluid (DEF) - 55 Gallon Drum

32.5

Standard
OSHA HCS 2024 · GHS Rev. 7
Revised
Emergency
Chemtel 1-800-255-3924 (24/7)
Download Full SDS PDF

The downloadable PDF is a print of this page and carries all 16 OSHA HCS sections.

Last reviewed 2026-11-24 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).
CAS number
57-13-6
Structure
2D chemical structure of Diesel Exhaust Fluid (DEF) - 55 Gallon Drum
Structure · PubChem
Grade
32.5
Section 1

Identification

Product Identifier
Diesel Exhaust Fluid (DEF) - 55 Gallon Drum
Concentration
32.5
CAS Number
57-13-6
Chemical Formula
CH4N2O (urea), 32.5 % w/w in H2O
Manufacturer
Alliance Chemical
204 South Edmond Street, Taylor, TX 76574
Emergency Phone
Chemtel 1-800-255-3924 (24/7)
Synonyms
DEF; AUS 32; aqueous urea solution 32.5 %; urea solution
Recommended Use
NOx reduction in selective catalytic reduction (SCR) systems of diesel engines: trucks, buses, farm, construction and mining equipment, generators.
Restrictions on Use
Use only through clean, dedicated DEF equipment; contamination can damage SCR systems. Do not dilute or add anything to it.
Section 2

Hazard Identification

Signal Word
No data available
Hazard Statements
No data available
Precautionary Statements
No data available
Section 3

Composition / Information on Ingredients

Composition and information on ingredients
ComponentCAS No.FormulaConcentration
Water7732-18-5H2O67.5% (w/w)
Urea57-13-6CH4N2O32.5% (w/w)

Concentrations are nominal; lot-specific values appear on the Certificate of Analysis. Components not contributing to classification are omitted.

Section 4

First-Aid Measures

Eyes
Rinse with plenty of water for at least 15 minutes. Remove contact lenses if present and easy to do. Continue rinsing. Seek medical attention immediately.
Skin
Immediately flush with plenty of water for at least 15 minutes while removing contaminated clothing. Wash with soap. Get medical attention immediately.
Inhalation
Move person to fresh air and keep comfortable for breathing. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Get medical attention immediately.
Ingestion
Do Not Induce Vomiting! Never give anything by mouth to an unconscious person. If conscious, wash out mouth with water. Get medical attention immediately.
Most Important Symptoms and Effects
  • No specific symptoms are expected from the hazards identified in Section 2.
Immediate Medical Attention and Special Treatment
  • Treat symptomatically. Get medical attention if symptoms develop or persist.
Section 5

Fire-Fighting Measures

Suitable Extinguishing Media
Use water spray, alcohol-resistant foam, dry chemical, or CO2. Use measures appropriate to local circumstances.
Unsuitable Extinguishing Media
Do not use a solid water stream as it may scatter and spread fire.
Specific Hazards Arising from the Chemical
Containers may rupture when heated.
Protective Equipment
Wear self-contained breathing apparatus and full protective clothing.
Hazardous Combustion Products
Ammonia when heated; carbon monoxide and carbon dioxide in a fire.
Section 6

Accidental Release Measures

Personal Precautions
Use PPE as described in Section 8. Ensure adequate ventilation. Evacuate personnel to safe areas.
Environmental Precautions
Prevent leakage or spillage from entering drains, sewers, or waterways.
Containment & Cleanup
Absorb with inert material. Collect in appropriate waste container. Dispose per applicable regulations.
Section 7

Handling and Storage

Safe Handling
Use with adequate ventilation. Avoid contact with skin, eyes, and clothing. Wash thoroughly after handling. Keep container closed when not in use.
Safe Storage
Store in a cool, dry, well-ventilated area. Keep away from incompatible materials (see Section 10). Keep containers tightly closed.
Specific Storage Precautions
Keep in the original sealed container in a cool, well-ventilated place out of direct sunlight, ideally between −5 °C and 30 °C (23–86 °F). Keep closed when not in use.
Section 8

Exposure Controls / Personal Protection

Occupational Exposure Limits

No established occupational exposure limits.

Engineering Controls
Use adequate ventilation. Provide eyewash stations and quick-drench showers accessible to areas of use.
Eye/Face Protection
Wear chemical safety goggles or face shield.
Skin Protection
Wear chemical-resistant gloves and protective clothing.
Respiratory Protection
Use NIOSH-approved respirator if exposure limits are exceeded or irritation occurs.
Section 9

Physical & Chemical Properties

Appearance
Clear, colorless liquid
Odor
Slight ammonia odor
Odor Threshold
No data available
pH
9–10
Melting Point / Freezing Point
Freezes at −11 °C (12 °F)
Boiling Point
Above 100 °C (212 °F)
Flash Point
Not flammable (aqueous solution)
Evaporation Rate
No data available
Flammability (solid, gas)
No data available
Upper/Lower Flammability or Explosive Limits
No data available
Vapor Pressure
No data available
Vapor Density
No data available
Relative Density
1.09 (water = 1)
Solubility
Miscible with water
Partition Coefficient (n-octanol/water)
No data available
Auto-ignition Temperature
No data available
Decomposition Temperature
No data available
Viscosity
No data available
Particle Characteristics
Not applicable
Form
Liquid

Values shown reflect product-specific canonical data. Lot-specific ranges may vary; see the Certificate of Analysis for the shipped lot.

Section 10

Stability and Reactivity

Reactivity
Not reactive under normal conditions of use and storage.
Chemical Stability
Stable under recommended storage conditions.
Possibility of Hazardous Reactions
None under normal processing conditions.
Conditions to Avoid
Direct sunlight, heat and temperatures above 30 °C (86 °F), which slowly break urea down to ammonia; freezing below −11 °C (12 °F).
Incompatible Materials
Strong acids, strong bases and oxidizing agents (peroxides, chromates, dichromates).
Hazardous Decomposition Products
Ammonia when heated; carbon monoxide and carbon dioxide in a fire.
Section 11

Toxicological Information

See below for route-specific acute toxicity data.

Likely Routes of Exposure
Inhalation, skin contact, eye contact, ingestion.
Symptoms
  • No specific symptoms are expected from the hazards identified in Section 2.
Delayed and Chronic Effects
  • No delayed or chronic effects identified beyond the classification in Section 2.
Acute toxicity
RouteValue
LD50 Oral8,471 mg/kg (rat, urea)

Carcinogen Classification

Carcinogen classification
AgencyStatus
IARCNot listed as carcinogen.
NTPNot listed as carcinogen.
OSHANot listed as carcinogen.
Section 12

Ecological Information

Ecotoxicity
Data not available. Avoid release to the environment.
Persistence & Degradability
Not Available
Bioaccumulative Potential
Not Available
Mobility in Soil
Not Available
Section 13

Disposal Considerations

Dispose of contents/container in accordance with applicable federal, state, and local regulations. Do not dispose of into drains or waterways.

EPA RCRA Waste Codes
Not a P- or U-listed waste and not a characteristic hazardous waste. The generator makes the final determination.
Section 14

Transport Information

Not regulated for transport under US DOT 49 CFR Subchapter C, IMDG, or IATA DGR.

Section 15

Regulatory Information

Regulatory inventory listings
Inventory / ListStatus
California Proposition 65Not listed
US EPA TSCA Active InventoryListed
EPCRA SARA 313 (TRI)Not listed
CERCLA Reportable Quantity (RQ)
Not a CERCLA hazardous substance (no RQ) and not an EPCRA Section 313 chemical.

SARA 311/312 hazard categories correspond to the GHS classification in Section 2. Data retrieved as of: California Proposition 65 2026-11-02; US EPA TSCA Active Inventory 2026-11-02; EPCRA SARA 313 (TRI) 2026-11-02.

Section 16

Other Information

Revision Date
Format
16-section format per OSHA HCS 2024 (29 CFR 1910.1200, Appendix D), aligned with GHS Rev. 7.

Disclaimer: The information provided in this Safety Data Sheet is correct to the best of our knowledge at the date of publication. It relates only to the specific product identified and does not relate to its use in combination with other materials. ALLIANCE CHEMICAL MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ALLIANCE CHEMICAL DOES NOT ASSUME LIABILITY FOR LOSS, INJURY, DAMAGE, OR EXPENSE ARISING FROM THE HANDLING, STORAGE, USE, OR DISPOSAL OF THIS PRODUCT.

Alliance Chemical, 204 South Edmond Street, Taylor, TX 76574. Published by Alliance Chemical from first-party canonical product data. Our authority is hands-on chemical handling, DOT/GHS-compliant shipping, and government-registered distribution — not bench chemistry. This Safety Data Sheet is prepared from the regulatory data on file for this product.