Industrial chemicals · Taylor, TX
Safety Data Sheet

Safety Data Sheet · OSHA HCS 2024

Glycerin Technical Grade

Technical Grade

Standard
OSHA HCS 2024 · GHS Rev. 7
Reviewed
Emergency
Chemtel 1-800-255-3924 (24/7)
Download Full SDS PDF

The downloadable PDF is a print of this page and carries all 16 OSHA HCS sections.

Last reviewed 2026-06-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).
CAS number
56-81-5
Structure
2D chemical structure of Glycerin Technical Grade
Structure · PubChem
Grade
Technical Grade
Section 1

Identification

Product Identifier
Glycerin Technical Grade
Grade
Technical Grade
CAS Number
56-81-5
Chemical Formula
C3H8O3
Molecular Weight
92.09 g/mol
Manufacturer
Alliance Chemical
204 South Edmond Street, Taylor, TX 76574
Emergency Phone
Chemtel 1-800-255-3924 (24/7)
Synonyms
Glycerol; glycerine; 1,2,3-propanetriol
Recommended Use
Humectant, plasticizer and solvent in industrial formulations, inks, adhesives, antifreeze and lubricants.
Restrictions on Use
Technical grade: not for food, drug or cosmetic use.
Section 2

Hazard Identification

Signal Word
Not applicable
Hazard Statements
Not classified as hazardous under GHS based on available data.
Precautionary Statements
No specific GHS precautionary statements required.
Section 3

Composition / Information on Ingredients

Composition and information on ingredients
ComponentCAS No.FormulaConcentration
Glycerin56-81-5C3H8O399-100% (w/w)

Concentrations are nominal; lot-specific values appear on the Certificate of Analysis. Components not contributing to classification are omitted.

Section 4

First-Aid Measures

Eyes
Rinse with water. Get medical attention if irritation develops or persists.
Skin
Wash with soap and water. Get medical attention if irritation develops.
Inhalation
Move to fresh air if discomfort occurs.
Ingestion
Rinse mouth with water. Get medical attention if you feel unwell.
Most Important Symptoms and Effects
  • No specific symptoms are expected from the hazards identified in Section 2.
Immediate Medical Attention and Special Treatment
  • Treat symptomatically. Get medical attention if symptoms develop or persist.
Section 5

Fire-Fighting Measures

Suitable Extinguishing Media
Use water spray, alcohol-resistant foam, dry chemical, or CO2. Use measures appropriate to local circumstances.
Unsuitable Extinguishing Media
Do not use a solid water stream as it may scatter and spread fire.
Specific Hazards Arising from the Chemical
Containers may rupture when heated.
Protective Equipment
Wear self-contained breathing apparatus and full protective clothing.
Hazardous Combustion Products
Acrolein (a severe irritant) when overheated; carbon monoxide and carbon dioxide on combustion.
Section 6

Accidental Release Measures

Personal Precautions
Wear safety glasses and gloves for cleanup. Spills can make floors slippery.
Environmental Precautions
Avoid releasing large quantities to drains or waterways.
Containment & Cleanup
Absorb or wipe up, then rinse the area with water. Dispose of according to local regulations.
Section 7

Handling and Storage

Safe Handling
Use with adequate ventilation. Avoid contact with skin, eyes, and clothing. Wash thoroughly after handling. Keep container closed when not in use.
Safe Storage
Store in a cool, dry, well-ventilated area. Keep away from incompatible materials (see Section 10). Keep containers tightly closed.
Specific Storage Precautions
Keep tightly closed (hygroscopic) in a dry place away from strong oxidizers. Stainless steel, aluminum or polyethylene containers.
Section 8

Exposure Controls / Personal Protection

Occupational Exposure Limits

Occupational exposure limits
LimitValue
OSHA PEL15 mg/m³ TWA total / 5 mg/m³ TWA respirable
ACGIH TLV10 mg/m³ TWA (mist)
NIOSH REL5 mg/m³ TWA (mist)
Engineering Controls
General ventilation is normally adequate.
Eye/Face Protection
Safety glasses are recommended.
Skin Protection
Gloves are recommended for prolonged or repeated contact.
Respiratory Protection
Not normally required.

Exposure limits sourced from NIOSH Pocket Guide, OSHA 29 CFR 1910.1000 and ACGIH TLVs.

Section 9

Physical & Chemical Properties

Appearance
Viscous clear liquid, transparent colorless
Odor
Odorless
Odor Threshold
No data available
pH
Neutral (5.5–8 in aqueous solution)
Melting Point / Freezing Point
18–20 °C (64–68 °F); readily supercools and stays liquid
Boiling Point
290 °C (554 °F), with decomposition
Flash Point
160–199 °C (320–390 °F)
Evaporation Rate
No data available
Flammability (solid, gas)
No data available
Upper/Lower Flammability or Explosive Limits
LEL 0.9–2.7% / UEL 19% (v/v in air)
Vapor Pressure
Below 0.001 hPa at 20 °C (negligible)
Vapor Density
3.2 (air = 1)
Relative Density
1.25–1.26 at 20 °C (water = 1)
Solubility
Completely miscible with water; hygroscopic
Partition Coefficient (n-octanol/water)
log Kow -1.75
Auto-ignition Temperature
370–429 °C (698–804 °F)
Decomposition Temperature
No data available
Viscosity
About 1,400 mPa·s at 20 °C
Particle Characteristics
Not applicable
Form
Liquid
Density
1.261 at 68 °F (USCG, 1999) - Denser than water; will sink

Values shown reflect product-specific canonical data. Lot-specific ranges may vary; see the Certificate of Analysis for the shipped lot.

Section 10

Stability and Reactivity

Reactivity
Not reactive under normal conditions of use and storage.
Chemical Stability
Stable under recommended storage conditions.
Possibility of Hazardous Reactions
None under normal processing conditions.
Conditions to Avoid
Strong heating (decomposes near 290 °C to acrolein); contact with strong oxidizers; moist air (hygroscopic).
Incompatible Materials
Strong oxidizing agents (violent reaction with potassium permanganate, chromium trioxide and similar); strong bases.
Hazardous Decomposition Products
Acrolein (a severe irritant) when overheated; carbon monoxide and carbon dioxide on combustion.
Section 11

Toxicological Information

See below for route-specific acute toxicity data.

Likely Routes of Exposure
Inhalation, skin contact, eye contact, ingestion.
Symptoms
  • No specific symptoms are expected from the hazards identified in Section 2.
Delayed and Chronic Effects
  • No delayed or chronic effects identified beyond the classification in Section 2.
Acute toxicity
RouteValue
LD50 Oral (rat)12,600 mg/kg (rat)
LD50 Dermal (rabbit)> 10,000 mg/kg

Carcinogen Classification

Carcinogen classification
AgencyStatus
IARCNot listed as carcinogen.
NTPNot listed as carcinogen.
OSHANot listed as carcinogen.
Section 12

Ecological Information

Ecotoxicity
Daphnia EC50: > 10000 mg/L (24 h, Daphnia magna (≤24 h), formulated product; 24-h window); Fish LC50: > 5000 mg/L (24 h, Goldfish (modified ASTM D 1345); 24-h window)
Persistence & Degradability
Not persistent; low soil/sediment adsorption, not expected to volatilize
Bioaccumulative Potential
log Kow −1.76
Mobility in Soil
Very high mobility in soil (estimated Koc ≈ 1)
Section 13

Disposal Considerations

Dispose of contents/container in accordance with applicable federal, state, and local regulations. Do not dispose of into drains or waterways.

EPA RCRA Waste Codes
Not a listed or characteristic hazardous waste.
Section 14

Transport Information

Not regulated for transport under US DOT 49 CFR Subchapter C, IMDG, or IATA DGR.

Section 15

Regulatory Information

Regulatory inventory listings
Inventory / ListStatus
California Proposition 65Not listed
US EPA TSCA Active InventoryListed
EPCRA SARA 313 (TRI)Not listed
CERCLA Reportable Quantity (RQ)
Not a CERCLA hazardous substance (no RQ); not an EPCRA Section 313 chemical.

SARA 311/312 hazard categories correspond to the GHS classification in Section 2. Data retrieved as of: California Proposition 65 2026-10-02; US EPA TSCA Active Inventory 2026-10-02; EPCRA SARA 313 (TRI) 2026-10-02.

Section 16

Other Information

Revision Date
Format
16-section format per OSHA HCS 2024 (29 CFR 1910.1200, Appendix D), aligned with GHS Rev. 7.

Disclaimer: The information provided in this Safety Data Sheet is correct to the best of our knowledge at the date of publication. It relates only to the specific product identified and does not relate to its use in combination with other materials. ALLIANCE CHEMICAL MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ALLIANCE CHEMICAL DOES NOT ASSUME LIABILITY FOR LOSS, INJURY, DAMAGE, OR EXPENSE ARISING FROM THE HANDLING, STORAGE, USE, OR DISPOSAL OF THIS PRODUCT.

Alliance Chemical, 204 South Edmond Street, Taylor, TX 76574. Published by Alliance Chemical from first-party canonical product data. Our authority is hands-on chemical handling, DOT/GHS-compliant shipping, and government-registered distribution — not bench chemistry. This Safety Data Sheet is prepared from the regulatory data on file for this product.