Technical Data Sheet
50%
| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Propylene glycol content | 49.5 - 50.5 % w/w | 50.0 % w/w | Formulation (batch weights); verified by refractive index against an in-house propylene glycol calibration / relative density (ASTM D1122) | Interpreted |
| Corrosion inhibitor package | 1.8 - 2.2 % w/w (nitrite-containing hybrid organic-acid) | 2.0 % w/w | Formulation (batch weights) | Interpreted |
| Nitrite (as NO2) | 1,200 ppm min. (calculated 1,300–2,700 ppm at the 2.0% dose) | Conforms | Formulation minimum (calculated from inhibitor dose) | Interpreted |
| Freeze point | -27 °F (-32.8 °C) max | approx. -28 °F (-33 °C) | ASTM D1177 | Interpreted |
Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.
| Grade | Concentration | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade — | 50% | — | current | current |
| Technical Grade | 50% | — | 50-propylene-glycol-technical-grade | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
| Property | Value | Source |
|---|---|---|
| Appearance | Clear, colorless to pale yellow liquid, free of sediment and suspended matter (not dyed) | Interpreted |
| Odor | Mild, characteristic | Adjudicated |
| pH | 7.0 - 9.0 (typical) | Interpreted |
| Specific Gravity | 1.042-1.050 (20 °C), calculated from formulation | Adjudicated |
| Density | approx. 1.04 g/mL (8.7 lb/gal) at 20 °C | Adjudicated |
| Boiling Point | approx. 106 °C (222 °F) at 760 mmHg | Adjudicated |
| Melting Point | Freeze point approx. -33 °C (-28 °F) at 50 wt% propylene glycol | Adjudicated |
| Flash Point | Not flammable (aqueous solution) | Adjudicated |
| Solubility (water) | Miscible with water | Adjudicated |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for 50% Propylene Glycol Inhibited. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
50% Propylene Glycol Inhibited is a glycol-based heat-transfer and freeze-protection fluid. Concentration sets the freeze and burst protection; the inhibitor package sets how long the system stays protected from corrosion.
Verify concentration against the required freeze and burst protection, and confirm elastomer and metallurgy compatibility for the service temperature. Only a USP or food-grade propylene glycol is suitable where incidental food or potable contact is possible; inhibited grades are for closed-loop heat-transfer service only.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Not regulated for transport.
A package holding 22,700 lb (10,310 kg), about 2,590 US gal, or more of this product contains a reportable quantity (RQ) and ships as:
UN3082, Environmentally hazardous substance, liquid, n.o.s. (Sodium nitrite), 9, III, RQ
Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-07-16 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.5 | 2026-10-13 | Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.4 | 2026-09-24 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.3 | 2026-09-09 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.2 | 2026-07-24 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.1 | 2026-07-16 | Canonical data re-verified: 4 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.