Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

A-A-59601E Type III ACS Grade

ACS Grade

Alliance Code
a-a-59601e-type-iii-acs-grade
Reviewed
2026-07-17
Revision
1.6
CAS number
64742-47-8
Structure
2D chemical structure of A-A-59601E Type III ACS Grade
Structure · PubChem
Grade
ACS Grade
Signal word
Danger
Hazards
Irritant / harmfulHealth hazardH304 H336
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

Product Name
A-A-59601E Type III ACS Grade
Alliance Code
a-a-59601e-type-iii-acs-grade
Grade
ACS Grade
Concentration
—
CAS Number
64742-47-8Adjudicated
Formula
MixtureAdjudicated
Molecular Weight
VariesAdjudicated
Product Type
Pure substance

Specifications

TestSpecificationTypicalMethodSource
Total chlorine content100 ppm, max.1.5 ppm—Interpreted
Aniline point73 to 89 °C81 °CASTM D611Interpreted
Aniline point (Type III)73 to 89 °C81 °CASTM D 611Interpreted
Initial boiling point220 °C min.233 °CASTM D86Interpreted
Color, Saybolt (Type III)30, min.+30ASTM D 156Interpreted
Copper corrosion2a, max.1aASTM D 130Interpreted
Doctor testNegativePasses testASTM D 235Interpreted
Dry point295 °C max.266 °CASTM D86Interpreted
Flash point93.3 °C (200 °F) min.100 °CASTM D56Interpreted
Kauri-butanol value27 to 4534ASTM D1133Interpreted
Non-volatile residue10 mg/100 ml, max.0.6 mg/100 mlASTM F 331Interpreted
Distillation, 90 % recovered275 °C max.257 °CASTM D86Interpreted
Sulfur, total30 ppm, max.0.56 ppmASTM D5453 (UV fluorescence)Interpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

Available GradesSame CAS, alternate grades and concentrations

GradeConcentrationTypical AssaySKUTDS
This grade ACS Grade——currentcurrent
Technical——a-a-59601e-type-iiiView TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

Physical & Chemical Properties

PropertyValueSource
AppearanceClear, colorless liquidAdjudicated
OdorHydrocarbon-likeAdjudicated
pHNot applicable (non-aqueous)Published reference
Specific Gravity0.81 at 15.6 °C (water = 1)Adjudicated
Density~0.79 g/mL at 15 °CPublished reference
Boiling Point242–276 °C (468–529 °F) distillation rangeAdjudicated
Melting Point-22 °C (-8 °F), freezing pointAdjudicated
Flash Point101 °C (213.8 °F), closed cup (ASTM D56)Adjudicated
Vapor Pressure< 0.1 mmHg at 20 °CAdjudicated
Solubility (water)Negligible in waterAdjudicated
Viscosity2.5–3.8 mm²/s at 20–40 °CAdjudicated

Regulatory & Transport

DOT / 49 CFR

UN Number
Not regulatedAdjudicated
Hazard Class
Not regulatedAdjudicated
Packing Group
Not regulatedAdjudicated
Proper Shipping Name
Not regulatedAdjudicated

GHS / OSHA HCS 2024

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H304, H336Adjudicated
P-Codes (Precautionary Statements)
P260, P264, P271, P280, P301+P310, P304+P340, P312, P331, P403+P233, P405, P501Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
500 ppm TWAOSHA 29 CFR 1910.1000
ACGIH TLV
—no canonical
NIOSH REL
350 mg/m³ TWA / 1800 mg/m³ Ceiling (15 min)NIOSH Pocket Guide
NIOSH IDLH
20000 mg/m³NIOSH Pocket Guide

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for A-A-59601E Type III ACS Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Applications

  • Hydrocarbon solvent used in the dry cleaning and coatings industries and, in military service, for degreasing and cleaning painted or unpainted metal parts (sourced from revision D of the A-A-59601 CID).everyspec.com
  • Type III (low odor, very high flash point) is intended for cleaning where confined atmospheric conditions require a cleaner conforming to federal directives for reducing hazardous materials.everyspec.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
Keep closed in a cool, well-ventilated place away from oxidizers and heat. Store locked up.Adjudicated
Handling Precautions
Use standard chemical PPE — splash goggles, gloves, lab coat. Refer to SDS for hazard-specific PPE requirements.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong oxidizing agents.Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

Not regulated for transport.

Confirm against shipping documents and carrier requirements before tender.

NMFC Class
55

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.62026-10-08Canonical data updated: 22 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
  • restrictions_on_use· canonical change (coa.data_provenance / adjudication)
  • odor· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • specificGravity· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • viscosity· canonical change (coa.data_provenance / adjudication)
  • autoIgnitionTemperature· canonical change (coa.data_provenance / adjudication)
  • explosiveLimits· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
  • dot_transport_note· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-10-05Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
  • oel_osha_pel· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-09-30Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • appearance· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-09-10Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • flashPoint· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 14 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • bulkThresholdGallons· canonical adjudication / reground (coa.data_provenance)
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • dotProperShippingName· canonical adjudication / reground (coa.data_provenance)
  • dotSubsidiaryHazardClass· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazardClass· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • packingGroup· canonical adjudication / reground (coa.data_provenance)
  • physicalProperties· canonical adjudication / reground (coa.data_provenance)
  • regulationRule· canonical adjudication / reground (coa.data_provenance)
  • signalWord· canonical adjudication / reground (coa.data_provenance)
  • unNumber· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.