Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Acetic Acid Glacial Technical

Technical

CAS Number
64-19-7
Alliance Code
acetic-acid-glacial-technical
Generated
2026-08-31
Revision
1.2
Reviewed
2026-07-17 · Andre Taki
2D chemical structure of Acetic Acid Glacial Technical
Structure · PubChem
Last reviewed 2026-07-17 by Andre Taki, DOT Hazmat Specialist.

Identity & Composition

Product Name
Acetic Acid Glacial Technical
Alliance Code
acetic-acid-glacial-technical
Grade
Technical
Concentration
CAS Number
64-19-7PubChem
Formula
C2H4O2PubChem
Molecular Weight
60.05PubChem
Product Type
pure_substance

Specifications

TestSpecificationTypicalMethodSource
AssayMIN. 99.85 WT%99.92 WT%Supplier specification
Aldehydes, as acetaldehyde0.05 %(m) max0.002 %(m)Supplier specification
ChloridesMAX. 1 PPM0.2 PPMSupplier specification
Formic acidMAX. 0.05 WT%0.003 WT%Supplier specification
Heavy metalsMAX. 0.5 PPM0.1 PPMSupplier specification
Permanganate time2 hours min.3.5Supplier specification
Non-volatile matter0.01 wt-% max0.0003 wt-%Supplier specification
Sulfates1.2 ppm max0.3 ppmSupplier specification
IronMAX. 0.5 PPM0.05 PPMSupplier specification
WaterMAX. 0.15 WT%0.06 WT%Karl Fischer, ASTM E203Supplier specification
acoh freeze point16.35 C min16.50 CSupplier specification
heavy metal0.5 mg/kg max0.1 mg/kgSupplier specification
iodide10 ppb max0.5 ppbSupplier specification
propionic acid300 ppm max90 ppmSupplier specification
sulfurous acid1 ppm(m) max0.1 ppm(m)Supplier specification
total sulfur1 ppm max0.2 ppmSupplier specification

Specification values are guaranteed limits. Typical values are representative of production lots and are not guaranteed. Lot-specific certificates of analysis ship with every order.

Available GradesSame CAS, alternate grades and concentrations

GradeConcentrationTypical AssaySKUTDS
This grade Technicalcurrentcurrent
ACS Gradeacetic-acid-glacial-99-acs-gradeView TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

Physical & Chemical Properties

PropertyValueSource
AppearanceCLEAR AND FREE OF SUSPENDED MATTERSupplier specification
FormLiquidPublished reference
ColorMAX. 5Supplier specification
OdorPungentPublished reference
pHAqueous solution 1.0 molar = 2.4; 0.1 molar = 2.9; 0.01 molar = 3.4Published reference
Specific Gravity (20 °C)1.048 - 1.053Supplier specification
Density1.051 at 68 °F (USCG, 1999) - Denser than water; will sinkPublished reference
Boiling Point244 °F at 760 mmHg (NTP, 1992)Published reference
Melting PointMIN. 16.35 ºCSupplier specification
Flash Point104 °F (NTP, 1992)Published reference
Vapor Pressure11.4 mmHg at 68 °F ; 20 mmHg at 86 °F (NTP, 1992)Published reference
Solubility (water)greater than or equal to 100 mg/mL at 73 °F (NTP, 1992)Published reference

Strong acid — density and vapor-pressure values shown are at 20 °C; values shift markedly with concentration and temperature. Reference concentration-temperature curves before specifying equipment.

Materials of Construction

MaterialRatingConditionsSource
stainless steelCompatiblechemically pure acetic acid (99.85% mass min. per the same sheet) and 80% acetic acidingredi.com
high density polyethylene (HDPE)Compatiblechemically pure acetic acid (99.85% mass min. per the same sheet) and 80% acetic acidingredi.com
glassCompatiblechemically pure acetic acid (99.85% mass min. per the same sheet) and 80% acetic acidingredi.com
aluminiumLimitedchemically pure (glacial) acetic acid only; not suitable for water-containing/dilute acidingredi.com
high density polyethyleneCompatibleChemically pure acetic acid; no temperature statedingredi.com

Compatibility is drawn from published manufacturer and supplier documentation for this product; each rating is sourced. Confirm against your specific duty cycle before equipment selection.

Materials Selection Tool

Showing 17 of 17 materials compatible at the selected envelope.

MaterialRatingMax T (°C)Notes
Buna-N (NBR)
elastomer
PoorHardens and cracks; do not use.
EPDM
elastomer
Good80Standard for HCl and H2SO4 gaskets.
Viton (FKM)
elastomer
Good80Acceptable for HCl gaskets up to 37 %.
PTFE
fluoropolymer
Excellent200Universal acid compatibility.
PVDF (Kynar)
fluoropolymer
Excellent120Excellent for HCl piping at elevated temperature.
Borosilicate Glass
glass ceramic
Excellent100Inert to most strong acids (avoid HF).
Glass (borosilicate)
glass ceramic
Excellent100Inert under all conditions
316 stainless steel
metal
Poor25Severe pitting; use only for vapors
Aluminium
metal
Not recommendedReacts to form H2 gas
Carbon Steel
metal
Not recommendedCatastrophic corrosion; never use.
Hastelloy C-276
metal
Excellent80Preferred metal for concentrated HCl service.
Inconel 625
metal
Good60Acceptable for dilute service
Tantalum
metal
Excellent100Best-in-class but expensive
CPVC
thermoplastic
Excellent90Higher-temp variant of PVC.
FRP (vinyl ester)
thermoplastic
Good60Common bulk-storage tank material
HDPE
thermoplastic
Excellent60Standard tank/drum material for HCl up to 37 %.
PVC
thermoplastic
Excellent60Common for piping; verify rating for service > 50 °C.

Regulatory & Transport

DOT / 49 CFR

UN Number
UN2789Adjudicated
Hazard Class
8Adjudicated
Packing Group
IIAdjudicated
Proper Shipping Name
Acetic acid, glacial or acetic acid solution, with more than 80 percent acid, by massAdjudicated

GHS / OSHA HazCom 2012

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H226, H314Adjudicated
P-Codes (Precautionary Statements)
P210, P233, P240, P241, P242, P243, P260, P264, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P370+P378, P403+P235, P405, P501Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
10 ppm TWAOSHA 29 CFR 1910.1000
ACGIH TLV
no canonical
NIOSH REL
10 ppm TWA / 15 ppm STELNIOSH Pocket Guide
NIOSH IDLH
50 ppmNIOSH Pocket Guide

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Acetic Acid Glacial Technical. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Honeywell

SKUGradeConc.MatchNotes
33209ACS99.8%ExactFluka ACS grade

Sigma-Aldrich

SKUGradeConc.MatchNotes
320099ACS Reagent99.7%ExactACS Reagent ≥99.7%

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Applications

  • Industrial manufacturing (relevant use identified on the glacial acetic acid safety data sheet)mubychem.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
Store in a well-ventilated place, keep cool, keep locked up, and avoid release to the environment; the same sheet states the material is flammable and explosive in the presence of oxidizing materialsmubychem.com
Handling Precautions
Use full PPE including face shield, acid-resistant gloves and apron. Add acid to water slowly with stirring; never reverse. Ventilation required.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
oxidizing materialsmubychem.com
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN2789, Acetic acid, glacial or acetic acid solution, with more than 80 percent acid, by mass, 8, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
60
Placard
Corrosive
Packing Group
PG II

Revision History

Last reviewed 2026-07-17 by Andre Taki, DOT Hazmat Specialist.

VersionDateChangeTrigger
1.22026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 5 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.