Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Blendpro - Professional Paint Thinning Solution Technical Grade

Technical

Alliance Code
blendpro-professional-paint-thinning-solution
Reviewed
2026-07-17
Revision
1.8
UN number
UN1263
Hazard class · packing group
3 · PG II
Structure
C3H6O
Molecular formula
Grade
Technical
Signal word
Danger
Formula
C3H6O
Hazards
FlammableIrritant / harmfulHealth hazardH225 H304 H319 H336
Proper shipping name
Paint related material including paint thinning, drying, removing, or reducing compound (Acetone, ethyl acetate, toluene)
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

Product Name
Blendpro - Professional Paint Thinning Solution Technical Grade
Alliance Code
blendpro-professional-paint-thinning-solution
Grade
Technical
Concentration
—
CAS Number
—Adjudicated
Formula
C3H6OAlliance SDS
Molecular Weight
58.08 g/molAlliance SDS
Product Type
Solution

Specifications

Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.

Physical & Chemical Properties

PropertyValueSource
AppearanceTransparent light-weight solvent liquidAdjudicated
OdorSolvent (acetone / ester / aromatic)Published reference
Specific Gravity~0.83Published reference
Density~0.83 g/mLPublished reference
Boiling Point56-111 °C (blend range: acetone 56 → toluene 111)Adjudicated
Flash Point≈ -9 °C (16 °F), closed cup — estimated for the ~1:1:1 acetone / ethyl acetate / toluene blend (acetone-governed); Class IB, H225Adjudicated
Solubility (water)Miscible with common organic solvents; partially water-miscible (acetone/ethyl-acetate fractions)Published reference

Regulatory & Transport

DOT / 49 CFR

UN Number
UN1263Adjudicated
Hazard Class
3Adjudicated
Packing Group
IIAdjudicated
Proper Shipping Name
Paint related material including paint thinning, drying, removing, or reducing compound (Acetone, ethyl acetate, toluene)Adjudicated

GHS / OSHA HCS 2024

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H225, H304, H319, H336Adjudicated
P-Codes (Precautionary Statements)
P210, P233, P240, P241, P242, P243, P264, P280, P301+P310, P303+P361+P353, P305+P351+P338, P312, P331, P337+P313, P370+P378, P403+P233, P403+P235, P405, P501Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
1000 ppm TWA (CAS 67-64-1); 400 ppm TWA (CAS 141-78-6); 200 ppm TWA / 300 ppm Ceiling (CAS 108-88-3)Adjudicated
ACGIH TLV
—no canonical
NIOSH REL
250 ppm TWA (CAS 67-64-1); 400 ppm TWA (CAS 141-78-6); 100 ppm TWA / 150 ppm STEL (CAS 108-88-3)Adjudicated
NIOSH IDLH
2500 ppm (CAS 67-64-1); 2000 ppm (CAS 141-78-6); 500 ppm (CAS 108-88-3)Adjudicated

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Blendpro - Professional Paint Thinning Solution Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Application Guidance

Blendpro - Professional Paint Thinning Solution Technical Grade (Technical) application guidance is available on request. Contact Alliance Chemical Technical Services for grade-specific use recommendations.

    Storage & Handling

    Recommended Storage
    Keep containers tightly closed in a cool, dry, well-ventilated flammable-liquids area away from heat, sparks, flame and combustible materials. Store locked up. Use explosion-proof equipment and non-sparking tools; ground and bond containers before transfer.Adjudicated
    Handling Precautions
    Use standard chemical PPE — splash goggles, gloves, lab coat. Refer to SDS for hazard-specific PPE requirements.Class-level guidance — not product-specific; the SDS controls.
    Incompatibilities
    Strong oxidizing agents (reacts violently with perchloric acid); strong acids; strong bases.Adjudicated
    Shelf Life
    Consult Technical Services for product-specific shelf life

    For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

    Packaging & Logistics

    Shipping Description (US DOT)

    UN1263, Paint related material including paint thinning, drying, removing, or reducing compound (Acetone, ethyl acetate, toluene), 3, PG II

    Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

    NMFC Class
    70
    Placard
    Flammable Liquid
    Packing Group
    PG II

    Revision History

    Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

    VersionDateChangeTrigger
    1.82026-10-13Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
    • storage_precautions· canonical change (coa.data_provenance / adjudication)
    • incompatible_materials· canonical change (coa.data_provenance / adjudication)
    • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
    • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
    canonical_change
    1.72026-10-07Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
    • ghsClassification· canonical change (coa.data_provenance / adjudication)
    • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
    • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
    canonical_change
    1.62026-10-05Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
    • oel_osha_pel· canonical change (coa.data_provenance / adjudication)
    • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
    • oel_idlh· canonical change (coa.data_provenance / adjudication)
    canonical_change
    1.52026-10-03Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
    • boilingPoint· canonical change (coa.data_provenance / adjudication)
    canonical_change
    1.42026-09-30Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
    • boilingPoint· canonical change (coa.data_provenance / adjudication)
    • appearance· canonical change (coa.data_provenance / adjudication)
    canonical_change
    1.32026-09-10Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
    • flashPoint· canonical change (coa.data_provenance / adjudication)
    canonical_change
    1.22026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
    • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
    • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
    canonical_change
    1.12026-07-17Canonical data re-verified: 5 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
    • casNumber· canonical adjudication / reground (coa.data_provenance)
    • ghsClassification· canonical adjudication / reground (coa.data_provenance)
    • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
    • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
    • physicalProperties· canonical adjudication / reground (coa.data_provenance)
    canonical_change
    1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

    This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.