Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Chromic Acid Flake Technical Grade

Alliance Code
SHOPIFY-15513835569385
Revised
2026-11-23
Revision
1.1
CAS number
1333-82-0
UN number
UN1463
Hazard class · packing group
5.1 · PG II
Structure
2D chemical structure of Chromic Acid Flake Technical Grade
Structure · PubChem
Signal word
Danger
Hazards
OxidizerCorrosiveAcute toxicityIrritant / harmfulHealth hazardEnvironmental hazardH271 H301 H311 H314 H317 H330 H334 H335 H340 H350 H361 H372 H400 H410
Proper shipping name
Chromium trioxide, anhydrous
Last reviewed 2026-11-23 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

Identity & Composition

Product Name
Chromic Acid Flake Technical Grade
Alliance Code
SHOPIFY-15513835569385
Grade
—
Concentration
—
CAS Number
1333-82-0Adjudicated
Formula
CrO3Adjudicated
Molecular Weight
99.99Adjudicated
Product Type
Pure substance

Specifications

Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.

Physical & Chemical Properties

PropertyValueSource
AppearanceDark red to red-brown flakesAdjudicated
FormSolidAdjudicated
OdorOdorlessAdjudicated
pHBelow 1 (aqueous solution)Adjudicated
Specific Gravity2.70 (water = 1)Adjudicated
Density2.70 g/cm³Adjudicated
Boiling PointNot applicable — decomposes above about 250 °CAdjudicated
Melting Point196 °C (385 °F)Adjudicated
Flash PointNot applicableAdjudicated
Vapor PressureNegligibleAdjudicated
Solubility (water)Very soluble in water (about 1,670 g/L at 20 °C), forming chromic acidAdjudicated

Oxidizer — decomposition rate and gas-evolution data may apply. Consult the SDS for material-of-construction guidance under shipping and storage conditions.

Materials of ConstructionService envelope ≈ 100%

MOC ratings are required for this chemical class but no compatibility data has been seeded yet. Treat as no-data and consult Alliance Technical Services before equipment selection.

Regulatory & Transport

DOT / 49 CFR

UN Number
UN1463Adjudicated
Hazard Class
5.1Adjudicated
Packing Group
IIAdjudicated
Proper Shipping Name
Chromium trioxide, anhydrousAdjudicated

GHS / OSHA HCS 2024

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H271, H301, H311, H314, H317, H330, H334, H335, H340, H350, H361, H372, H400, H410Adjudicated
P-Codes (Precautionary Statements)
P201, P202, P210, P220, P260, P261, P264, P270, P271, P272, P273, P280, P283, P284, P301+P310, P301+P330+P331, P302+P352, P303+P361+P353, P304+P340, P305+P351+P338, P306+P360, P308+P313, P310, P314, P320, P333+P313, P342+P311, P362, P363, P370+P378, P371+P380+P375, P391, P403+P233, P405, P501Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
0.005 mg/m³ TWA (as Cr(VI)); action level 0.0025 mg/m³ — 29 CFR 1910.1026Adjudicated
ACGIH TLV
0.0002 mg/m³ TWA; 0.0005 mg/m³ STEL (inhalable, as Cr(VI))Adjudicated
NIOSH REL
Ca — 0.0002 mg/m³ TWA (as Cr(VI))Adjudicated
NIOSH IDLH
15 mg/m³ (as Cr(VI))Adjudicated

Regional Classifications

EC Number (EU EINECS)
215-607-8Adjudicated

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Health & Fire Hazard

Acute Toxicology

LD₅₀ Oral
80 mg/kg (rat)Adjudicated

Acute toxicology values from SDS Section 11 or NIOSH RTECS.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Chromic Acid Flake Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Applications

Industrial uses: hexavalent chrome plating baths, chromate conversion coatings, anodizing seals, metal etching and oxidation processes.Adjudicated

Restrictions on Use: Industrial and professional use only. Not for consumer, food, drug or cosmetic use.

Storage & Handling

Recommended Storage
Store in tightly closed containers in a cool, dry, well-ventilated area, locked up, away from combustible and organic materials and reducing agents. Protect from moisture. Handle only with local exhaust; minimize dust.Adjudicated
Handling Precautions
Use PPE including face shield, chemical-resistant gloves, and apron. Avoid contamination — never return unused material to the original container. Ground all transfer equipment.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Combustible, organic and readily oxidizable materials (paper, wood, oils, sulfur, plastics), reducing agents, aluminum powder, ammonia, hydrogen sulfide, alcohols and acetone (can ignite on contact), alkali metals. Corrosive to metals.Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1463, Chromium trioxide, anhydrous, 5.1, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
65
Placard
Oxidizer
Packing Group
PG II

Revision History

Last reviewed 2026-11-23 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.12026-11-23Canonical data updated: 38 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
  • casNumber· canonical change (coa.data_provenance / adjudication)
  • formula· canonical change (coa.data_provenance / adjudication)
  • molecularWeight· canonical change (coa.data_provenance / adjudication)
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
  • restrictions_on_use· canonical change (coa.data_provenance / adjudication)
  • unNumber· canonical change (coa.data_provenance / adjudication)
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
  • signalWord· canonical change (coa.data_provenance / adjudication)
  • oel_osha_pel· canonical change (coa.data_provenance / adjudication)
  • oel_acgih_tlv· canonical change (coa.data_provenance / adjudication)
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
  • form· canonical change (coa.data_provenance / adjudication)
  • odor· canonical change (coa.data_provenance / adjudication)
  • pH· canonical change (coa.data_provenance / adjudication)
  • specificGravity· canonical change (coa.data_provenance / adjudication)
  • density· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • decompositionTemperature· canonical change (coa.data_provenance / adjudication)
  • partitionCoefficient· canonical change (coa.data_provenance / adjudication)
canonical change

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.