Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Copper Sulfate Pentahydrate Technical Grade

Alliance Code
SHOPIFY-15518430068969
Revised
2026-11-24
Revision
1.1
CAS number
7758-99-8
Structure
2D chemical structure of Copper Sulfate Pentahydrate Technical Grade
Structure · PubChem
Signal word
Danger
Hazards
CorrosiveIrritant / harmfulEnvironmental hazardH302 H315 H318 H400 H410
Last reviewed 2026-11-24 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

Identity & Composition

Product Name
Copper Sulfate Pentahydrate Technical Grade
Alliance Code
SHOPIFY-15518430068969
Grade
—
Concentration
—
CAS Number
7758-99-8Adjudicated
Formula
CuSO4·5H2OAdjudicated
Molecular Weight
249.68Adjudicated
Product Type
Pure substance

Specifications

Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.

Physical & Chemical Properties

PropertyValueSource
AppearanceBlue crystals (fine, about 20–60 mesh)Adjudicated
FormSolidAdjudicated
OdorOdorlessAdjudicated
pH3.7–4.4 (10% aqueous solution)Adjudicated
Specific Gravity2.28 (water = 1)Adjudicated
Density2.28 g/cm³Adjudicated
Melting PointLoses water of hydration on heating; anhydrous by about 150 °C (302 °F)Adjudicated
Flash PointNot applicableAdjudicated
Vapor PressureNegligibleAdjudicated
Solubility (water)Soluble in water (31.6 g/100 mL at 20 °C)Adjudicated

Materials of ConstructionService envelope ≈ 100%

MaterialRatingMax T (°C)NotesSource
Buna-N (NBR)
elastomer
Good60AcceptableCole-Parmer Chemical Compatibility
EPDM
elastomer
Excellent100Standard for brine gaskets.Parker O-ring Chemical Compatibility
Viton (FKM)
elastomer
Excellent100Preferred elastomerCole-Parmer Chemical Compatibility
Borosilicate Glass
glass ceramic
Excellent100Universally inert to salt solutions.Cole-Parmer Chemical Compatibility
Concrete (sealed)
glass ceramic
Good—Acceptable with epoxy coatingCole-Parmer Chemical Compatibility
304 stainless steel
metal
Fair25Pitting in chloride-rich serviceCole-Parmer Chemical Compatibility
316L Stainless Steel
metal
Good60Watch for chloride pitting above 60 °C in chloride salts.NACE Chloride Pitting Guidelines
Aluminium
metal
Poor—Pitting; not recommended for brineCole-Parmer Chemical Compatibility
Carbon steel
metal
Poor—Rapid rust in brineCole-Parmer Chemical Compatibility
FRP
thermoplastic
Excellent60Common bulk-storageCole-Parmer Chemical Compatibility
HDPE
thermoplastic
Excellent60Universal salt brine compatibility.Cole-Parmer Chemical Compatibility
PP
thermoplastic
Excellent80Acceptable for hot brineCole-Parmer Chemical Compatibility
PVC
thermoplastic
Excellent60Standard for brine piping.Cole-Parmer Chemical Compatibility

Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.

Materials Selection Tool

Showing 13 of 13 material ratings within the selected envelope.

MaterialRatingMax T (°C)Notes
Buna-N (NBR)
elastomer
Good60Acceptable
EPDM
elastomer
Excellent100Standard for brine gaskets.
Viton (FKM)
elastomer
Excellent100Preferred elastomer
Borosilicate Glass
glass ceramic
Excellent100Universally inert to salt solutions.
Concrete (sealed)
glass ceramic
Good—Acceptable with epoxy coating
304 stainless steel
metal
Fair25Pitting in chloride-rich service
316L Stainless Steel
metal
Good60Watch for chloride pitting above 60 °C in chloride salts.
Aluminium
metal
Poor—Pitting; not recommended for brine
Carbon steel
metal
Poor—Rapid rust in brine
FRP
thermoplastic
Excellent60Common bulk-storage
HDPE
thermoplastic
Excellent60Universal salt brine compatibility.
PP
thermoplastic
Excellent80Acceptable for hot brine
PVC
thermoplastic
Excellent60Standard for brine piping.

Regulatory & Transport

DOT / 49 CFR

UN Number
Not regulatedAdjudicated
Hazard Class
Not regulatedAdjudicated
Packing Group
Not regulatedAdjudicated
Proper Shipping Name
Not regulatedAdjudicated

GHS / OSHA HCS 2024

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H302, H315, H318, H400, H410Adjudicated
P-Codes (Precautionary Statements)
P264, P270, P273, P280, P301+P312, P302+P352, P305+P351+P338, P310, P330, P332+P313, P362, P363, P391, P501Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
1 mg/m³ TWA (copper dusts and mists, as Cu)Adjudicated
ACGIH TLV
1 mg/m³ TWA (copper dusts and mists, as Cu)Adjudicated
NIOSH REL
1 mg/m³ TWA (copper dusts and mists, as Cu)Adjudicated
NIOSH IDLH
100 mg/m³ (as Cu)Adjudicated

Regional Classifications

EC Number (EU EINECS)
231-847-6Adjudicated

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Health & Fire Hazard

Acute Toxicology

LD₅₀ Oral
330 mg/kg (rat)Adjudicated

Acute toxicology values from SDS Section 11 or NIOSH RTECS.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Copper Sulfate Pentahydrate Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Applications

Industrial, laboratory and educational uses: copper electroplating and electroforming baths, dye mordant, laboratory reagent, electrochemistry and batteries, chemistry education.Adjudicated

Restrictions on Use: Not registered as a pesticide: not for use as a pesticide, algaecide, fungicide or root killer. Not for food, feed, drug or cosmetic use.

Storage & Handling

Recommended Storage
Keep containers tightly closed in a cool, dry, well-ventilated area away from bases, reducing agents and metals it corrodes. Protect from moisture. Keep out of drains and waterways.Adjudicated
Handling Precautions
Standard chemical PPE — dust mask and goggles for handling of fine grades. Avoid generating airborne dust.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong bases, reducing agents, magnesium, hydroxylamine (ignites), hydrazine, acetylene and nitromethane (form explosive copper acetylides), zirconium, phosphates. Solutions corrode aluminum, steel and iron.Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

Not regulated for transport.

A package holding 10 lb (4 kg) or more of this product contains a reportable quantity (RQ) and ships as:

UN3077, Environmentally hazardous substance, solid, n.o.s. (Cupric sulfate), 9, III, RQ

Confirm against shipping documents and carrier requirements before tender.

NMFC Class
70

Revision History

Last reviewed 2026-11-24 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.12026-11-24Canonical data updated: 38 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
  • casNumber· canonical change (coa.data_provenance / adjudication)
  • formula· canonical change (coa.data_provenance / adjudication)
  • molecularWeight· canonical change (coa.data_provenance / adjudication)
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
  • restrictions_on_use· canonical change (coa.data_provenance / adjudication)
  • unNumber· canonical change (coa.data_provenance / adjudication)
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • signalWord· canonical change (coa.data_provenance / adjudication)
  • oel_osha_pel· canonical change (coa.data_provenance / adjudication)
  • oel_acgih_tlv· canonical change (coa.data_provenance / adjudication)
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
  • form· canonical change (coa.data_provenance / adjudication)
  • odor· canonical change (coa.data_provenance / adjudication)
  • pH· canonical change (coa.data_provenance / adjudication)
  • specificGravity· canonical change (coa.data_provenance / adjudication)
  • density· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • decompositionTemperature· canonical change (coa.data_provenance / adjudication)
  • partitionCoefficient· canonical change (coa.data_provenance / adjudication)
canonical change

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.