Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Drain Hammer - Sulfuric Acid Drain Cleaner

Technical · 93%

Alliance Code
drain-hammer-sulfuric-acid-drain-cleaner
Reviewed
2026-07-17
Revision
1.7
CAS number
7664-93-9
UN number
UN1830
Hazard class · packing group
8 · PG II
Structure
2D chemical structure of Drain Hammer - Sulfuric Acid Drain Cleaner
Structure · PubChem
Grade
Technical · 93%
Signal word
Danger
Hazards
CorrosiveH290 H314
Proper shipping name
Sulfuric acid with more than 51 percent acid
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

Product Name
Drain Hammer - Sulfuric Acid Drain Cleaner
Alliance Code
drain-hammer-sulfuric-acid-drain-cleaner
Grade
Technical
Concentration
93%
CAS Number
7664-93-9PubChem
Formula
—PubChem
Molecular Weight
98.08PubChem
Product Type
Mixture

Specifications

Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.

Physical & Chemical Properties

One or more physical-property values are temporarily suppressed pending verification against vendor COA data. For complete properties refer to the Safety Data Sheet (SDS) or contact sales@alliancechemical.com.

PropertyValueSource
AppearanceColorless, oily liquidAdjudicated
FormLiquidPublished reference
OdorOdorlessPublished reference
pH1 N solution = 0.3; 0.1 N solution = 1.2; 0.01 N solution = 2.1Published reference
Specific Gravity1.835Published reference
Density1.835 (93% w/w solution, 16 °C)Published reference
Boiling Point276 °C (529 °F) (93% solution)Adjudicated
Melting Point−29.5 °C (−21 °F) freezing point (93% solution)Adjudicated
Flash PointNot applicable (non-flammable)Published reference
Vapor Pressure1 mmHg at 294.8 °F (EPA, 1998)Published reference

Strong acid — density and vapor-pressure values shown are at 20 °C; values shift markedly with concentration and temperature. Reference concentration-temperature curves before specifying equipment.

Materials of ConstructionService envelope ≈ 93%

MOC ratings are required for this chemical class but no compatibility data has been seeded yet. Treat as no-data and consult Alliance Technical Services before equipment selection.

Regulatory & Transport

DOT / 49 CFR

UN Number
UN1830Adjudicated
Hazard Class
8Adjudicated
Packing Group
IIAdjudicated
Proper Shipping Name
Sulfuric acid with more than 51 percent acidAdjudicated

GHS / OSHA HCS 2024

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H290, H314Adjudicated
P-Codes (Precautionary Statements)
P234, P260, P264, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P390, P405, P406, P501Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
1 mg/m³ TWAOSHA 29 CFR 1910.1000
ACGIH TLV
—no canonical
NIOSH REL
1 mg/m³ TWANIOSH Pocket Guide
NIOSH IDLH
15 mg/m³NIOSH Pocket Guide

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Drain Hammer - Sulfuric Acid Drain Cleaner. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Sigma-Aldrich

SKUGradeConc.MatchNotes
258105ACS Reagent95-98%Unverified candidateACS Reagent 95–98%

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Application Guidance

Drain Hammer - Sulfuric Acid Drain Cleaner (Technical) is a strong mineral acid used across pH control, metal pickling, food and beverage processing, and chemical synthesis. Grade and concentration determine the appropriate end-use and materials.

  • Metal pickling, etching, and surface preparation
  • pH adjustment in water and wastewater treatment
  • Regeneration of ion-exchange resins
  • Chemical manufacturing and synthesis
  • Food and beverage processing (food-grade only)

Always add acid to water, never water to acid. Use lined or fluoropolymer piping rated for the concentration; carbon steel is not suitable for dilute acid service.

Storage & Handling

Recommended Storage
Keep tightly closed in acid-resistant containers in a cool, dry, ventilated area, away from water, bases, organics and metals. To dilute, add the acid slowly to water while stirring; never add water to the acid.Adjudicated
Handling Precautions
Use full PPE including face shield, acid-resistant gloves and apron. Add acid to water slowly with stirring; never reverse. Ventilation required.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Water (violent reaction with heat and spattering); bases; organic and combustible materials; reducing agents; chlorates, permanganates, nitrates, picrates, fulminates and carbides; cyanides and sulfides (release toxic gases); powdered metals and most metals (release flammable hydrogen).Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1830, Sulfuric acid with more than 51 percent acid, 8, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
60
Placard
Corrosive
Packing Group
PG II

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.72026-10-13Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
canonical_change
1.62026-10-08Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-10-07Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-10-05Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-09-30Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 6 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • physicalProperties· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.