Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Inhibited Propylene Glycol 20/80 with OAT Inhibitor — Data Center Coolant

20%

Alliance Code
SHOPIFY-15395850027241
Reviewed
2026-09-28
Revision
1.1
CAS number
57-55-6
Structure
2D chemical structure of Inhibited Propylene Glycol 20/80 with OAT Inhibitor — Data Center Coolant
Structure · PubChem
Grade
20%
Last reviewed 2026-09-28.

Identity & Composition

Product Name
Inhibited Propylene Glycol 20/80 with OAT Inhibitor — Data Center Coolant
Alliance Code
SHOPIFY-15395850027241
Grade
—
Concentration
20%
CAS Number
57-55-6Adjudicated
Formula
C3H8O2Adjudicated
Molecular Weight
76.09Adjudicated
Product Type
mixture

Specifications

Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.

Available GradesSame CAS, alternate grades and concentrations

GradeConcentrationTypical AssaySKUTDS
This grade —20%—currentcurrent
—50%—SHOPIFY-7859432226858View TDS →
—40%—SHOPIFY-7859432194090View TDS →
—35%—SHOPIFY-7990713942058View TDS →
—30%—SHOPIFY-7859429277738View TDS →
—25%—SHOPIFY-7990713909290View TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

Physical & Chemical Properties

PropertyValueSource
AppearanceClear, colorless to pale yellow liquid (not dyed)Published reference
OdorMild, characteristicPublished reference
pHTypically 7.0-9.0 (ASTM D1287); measured value reported on the lot Certificate of AnalysisPublished reference
Specific Gravity (20 °C)1.017-1.025 (20 °C), calculated from formulationPublished reference
Densityapprox. 1.02 g/mL (8.5 lb/gal) at 20 °CPublished reference
Boiling Pointapprox. 101 °C (214 °F) at 760 mmHgPublished reference
Melting PointFreeze point approx. -7 °C (19 °F) at 20 wt% propylene glycolPublished reference
Flash PointNot flammable (aqueous solution)Published reference
Solubility (water)Miscible with waterPublished reference

Regulatory & Transport

DOT / 49 CFR

UN Number
Not regulatedAdjudicated
Hazard Class
Not regulatedAdjudicated
Packing Group
Not regulatedAdjudicated
Proper Shipping Name
Not regulatedAdjudicated

GHS / OSHA HazCom 2012

Signal Word
Not regulatedAdjudicated
H-Codes (Hazard Statements)
—no canonical
P-Codes (Precautionary Statements)
—no canonical

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
—no canonical
ACGIH TLV
—no canonical
NIOSH REL
—no canonical
NIOSH IDLH
—no canonical

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Inhibited Propylene Glycol 20/80 with OAT Inhibitor — Data Center Coolant. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Application Guidance

Inhibited Propylene Glycol 20/80 with OAT Inhibitor — Data Center Coolant is a glycol-based heat-transfer and freeze-protection fluid. Concentration sets the freeze and burst protection; the inhibitor package sets how long the system stays protected from corrosion.

  • Closed-loop heat transfer and process cooling
  • Data-centre and chilled-water freeze protection
  • HVAC hydronic loops and glycol makeup
  • Freeze and burst protection for idle or seasonal systems

Verify concentration against the required freeze and burst protection, and confirm elastomer and metallurgy compatibility for the service temperature. Only a USP or food-grade propylene glycol is suitable where incidental food or potable contact is possible; inhibited grades are for closed-loop heat-transfer service only.

Storage & Handling

Recommended Storage
Cool, dry, well-ventilated area in tightly sealed original containers. Neat glycols are combustible liquids with high flash points (roughly 99–111 °C) and do not require a solvent store; aqueous blends will not sustain combustion. Protect inhibited coolants from contamination and from freezing below their stated protection point.Class-level guidance — not product-specific; the SDS controls.
Handling Precautions
Chemical-resistant gloves and splash goggles. Avoid contact with hot surfaces and hot process equipment. Inhibitor packages deplete in service — monitor rather than top up blindly.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong oxidizers, strong acids and strong bases. Galvanized (zinc) surfaces are attacked by many inhibited coolant packages. Verify elastomer and gasket compatibility for the service temperature; EPDM is standard for glycol/water service.Class-level guidance — not product-specific; the SDS controls.
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

Not regulated for transport.

Confirm against shipping documents and carrier requirements before tender.

NMFC Class
55

Revision History

VersionDateChangeTrigger
1.12026-09-28Canonical data updated: 11 fields changed via the provenance/adjudication pipeline.
  • physicalProperties· canonical change (coa.data_provenance / adjudication)
  • unNumber· canonical change (coa.data_provenance / adjudication)
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • signalWord· canonical change (coa.data_provenance / adjudication)
  • casNumber· canonical change (coa.data_provenance / adjudication)
  • formula· canonical change (coa.data_provenance / adjudication)
  • molecularWeight· canonical change (coa.data_provenance / adjudication)
canonical_change

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.