Technical Data Sheet
Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification; lot-specific certificates ship with every order.
| Material | Rating | Max T (°C) | Notes | Source |
|---|---|---|---|---|
Buna-N (NBR) elastomer | Good | 60 | Acceptable | Cole-Parmer Chemical Compatibility |
EPDM elastomer | Excellent | 100 | Standard for brine gaskets. | Parker O-ring Chemical Compatibility |
Viton (FKM) elastomer | Excellent | 100 | Preferred elastomer | Cole-Parmer Chemical Compatibility |
Borosilicate Glass glass ceramic | Excellent | 100 | Universally inert to salt solutions. | Cole-Parmer Chemical Compatibility |
Concrete (sealed) glass ceramic | Good | — | Acceptable with epoxy coating | Cole-Parmer Chemical Compatibility |
304 stainless steel metal | Fair | 25 | Pitting in chloride-rich service | Cole-Parmer Chemical Compatibility |
316L Stainless Steel metal | Good | 60 | Watch for chloride pitting above 60 °C in chloride salts. | NACE Chloride Pitting Guidelines |
Aluminium metal | Poor | — | Pitting; not recommended for brine | Cole-Parmer Chemical Compatibility |
Carbon steel metal | Poor | — | Rapid rust in brine | Cole-Parmer Chemical Compatibility |
FRP thermoplastic | Excellent | 60 | Common bulk-storage | Cole-Parmer Chemical Compatibility |
HDPE thermoplastic | Excellent | 60 | Universal salt brine compatibility. | Cole-Parmer Chemical Compatibility |
PP thermoplastic | Excellent | 80 | Acceptable for hot brine | Cole-Parmer Chemical Compatibility |
PVC thermoplastic | Excellent | 60 | Standard for brine piping. | Cole-Parmer Chemical Compatibility |
Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.
Showing 13 of 13 material ratings within the selected envelope.
| Material | Rating | Max T (°C) | Notes |
|---|---|---|---|
Buna-N (NBR) elastomer | Good | 60 | Acceptable |
EPDM elastomer | Excellent | 100 | Standard for brine gaskets. |
Viton (FKM) elastomer | Excellent | 100 | Preferred elastomer |
Borosilicate Glass glass ceramic | Excellent | 100 | Universally inert to salt solutions. |
Concrete (sealed) glass ceramic | Good | — | Acceptable with epoxy coating |
304 stainless steel metal | Fair | 25 | Pitting in chloride-rich service |
316L Stainless Steel metal | Good | 60 | Watch for chloride pitting above 60 °C in chloride salts. |
Aluminium metal | Poor | — | Pitting; not recommended for brine |
Carbon steel metal | Poor | — | Rapid rust in brine |
FRP thermoplastic | Excellent | 60 | Common bulk-storage |
HDPE thermoplastic | Excellent | 60 | Universal salt brine compatibility. |
PP thermoplastic | Excellent | 80 | Acceptable for hot brine |
PVC thermoplastic | Excellent | 60 | Standard for brine piping. |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for SODIUM CHLORIDE, TECHNICAL — NSN 6810-01-528-4690. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
SODIUM CHLORIDE, TECHNICAL — NSN 6810-01-528-4690 is supplied across multiple grades. Grade selection drives the appropriate end-use — food/pharma, technical, or specialty.
Often hygroscopic — store in sealed containers, control humidity. Hydrate form (anhydrous vs di/hexa-hydrate) affects mass-equivalent dosing.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.