Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Propylene Glycol Inhibited ACS Grade

ACS Grade

Alliance Code
propylene-glycol-inhibited-acs-grade
Reviewed
2026-06-17
Revision
1.3
CAS number
57-55-6
Structure
2D chemical structure of Propylene Glycol Inhibited ACS Grade
Structure · PubChem
Grade
ACS Grade
Last reviewed 2026-06-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

Product Name
Propylene Glycol Inhibited ACS Grade
Alliance Code
propylene-glycol-inhibited-acs-grade
Grade
ACS Grade
Concentration
—
CAS Number
57-55-6PubChem
Formula
C3H8O2PubChem
Molecular Weight
76.09PubChem
Product Type
Pure substance

Specifications

TestSpecificationTypicalMethodSource
Assay (CH3CHOHCH2OH), corrected for water>= 99.5 %99.91 %—Interpreted
Titrable acid<= 0.0005 meq/g0.00017 meq/g—Interpreted
Chloride1 ppm max.0.26 ppm—Interpreted
Color (APHA)10 max.4—Interpreted
Residue after ignition<= 0.005 %0.00035 %—Interpreted
Water<= 0.2 %0.029 %Karl Fischer titrationInterpreted
Sulfate (SO4), base glycol≤ 5 ppm1.0 ppmTurbidimetric (BaCl2) / ion chromatographyInterpreted
Heavy metals (as Pb), base glycol≤ 1 ppm0.18 ppmColorimetric sulfide / ICP-OESInterpreted
Iron (Fe), base glycol≤ 0.2 ppm0.053 ppmICP-OES / 1,10-phenanthrolineInterpreted
Distillation range, base glycol185.0 - 189.5 °C187.0 °CASTM D1078Interpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

Physical & Chemical Properties

PropertyValueSource
AppearanceClear, colorless viscous liquidAdjudicated
FormLiquidPublished reference
OdorPractically odorlessPublished reference
Density1.04 at 68 °F (USCG, 1999) - Denser than water; will sinkPublished reference
Boiling Point370.8 °F at 760 mmHg (NTP, 1992)Adjudicated
Melting Point-76 °F (NTP, 1992)Adjudicated
Flash Point210 °F (NTP, 1992)Adjudicated
Vapor Pressure0.08 mmHg at 68 °F ; 0.13 mmHg at 77 °F (NTP, 1992)Published reference
Solubility (water)greater than or equal to 100 mg/mL at 70 °F (NTP, 1992)Published reference
Refractive Index (nD 20)1.4310 - 1.4330Interpreted

Regulatory & Transport

DOT / 49 CFR

UN Number
Not regulatedAdjudicated
Hazard Class
Not regulatedAdjudicated
Packing Group
Not regulatedAdjudicated
Proper Shipping Name
Not regulatedAdjudicated

GHS / OSHA HCS 2024

Signal Word
Not regulatedAdjudicated
H-Codes (Hazard Statements)
Not applicableECHA C&L Inventory
P-Codes (Precautionary Statements)
Not applicableECHA C&L Inventory

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
—no canonical
ACGIH TLV
—no canonical
NIOSH REL
—no canonical
NIOSH IDLH
—no canonical

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Propylene Glycol Inhibited ACS Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Applications

  • Laboratory, research or manufacturing use (ACS reagent grade material)digitalassets.avantorsciences.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
Keep tightly closed (hygroscopic) in a cool, dry place away from oxidizers. Stainless steel, carbon steel, polyethylene or polypropylene containers.Adjudicated
Handling Precautions
Chemical-resistant gloves and splash goggles. Avoid contact with hot surfaces and hot process equipment. Inhibitor packages deplete in service — monitor rather than top up blindly.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong oxidizing agents; strong acids; strong bases.Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

Not regulated for transport.

Confirm against shipping documents and carrier requirements before tender.

NMFC Class
55

Revision History

Last reviewed 2026-06-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.32026-10-13Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-09-30Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-06-17Canonical data re-verified: 3 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • dotSubsidiaryHazardClass· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.