Technical Data Sheet
ACS · 80%
| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Assay (NaClO2) | 77.0 - 83.0 % | 80.0 % | — | Supplier specification |
| Aluminium (Al) | max. 5 ppm | 0.3 ppm | — | Supplier specification |
| Barium (Ba) | max. 5 ppm | 0.1 ppm | — | Supplier specification |
| Cadmium (Cd) | max. 5 ppm | 0.05 ppm | — | Supplier specification |
| Calcium (Ca) | max. 50 ppm | 4 ppm | — | Supplier specification |
| Chromium (Cr) | max. 5 ppm | 0.2 ppm | — | Supplier specification |
| Copper (Cu) | max. 5 ppm | 0.1 ppm | — | Supplier specification |
| Iron (Fe) | max. 5 ppm | 0.5 ppm | — | Supplier specification |
| Lead (Pb) | max. 5 ppm | 0.1 ppm | — | Supplier specification |
| Magnesium (Mg) | max. 10 ppm | 1 ppm | — | Supplier specification |
| Manganese (Mn) | max. 5 ppm | 0.05 ppm | — | Supplier specification |
| Nickel (Ni) | max. 5 ppm | 0.15 ppm | — | Supplier specification |
| Potassium (K) | max. 1000 ppm | 45 ppm | — | Supplier specification |
| Zinc (Zn) | max. 5 ppm | 0.2 ppm | — | Supplier specification |
| Sodium chlorate (NaClO3) | max. 3.0 % | 0.6 % | Iodometric titration after chlorite destruction / ion chromatography | Interpreted |
| Sodium chloride (NaCl) | max. 17.0 % | 13.9 % | Argentometric potentiometric titration (Volhard) | Interpreted |
| Free alkali (as NaOH) | max. 4.0 % | 1.1 % | Potentiometric titration with 0.1 N HCl to pH 8.3 | Interpreted |
| Sulfate (SO4) | max. 0.5 % | 0.02 % | Ion chromatography (or gravimetric as BaSO4) | Interpreted |
| Insoluble matter | max. 0.05 % | 0.005 % | Gravimetric, 10 g/100 mL solution filtered through tared sintered glass, dried 105 °C | Interpreted |
| Water | max. 5.0 % | 3.4 % | By difference from component balance (assay + NaCl + NaClO3 + NaOH + Na2SO4) | Interpreted |
| Arsenic (As) | max. 3 ppm | 0.05 ppm | ICP-MS (hydride generation AAS alternate) | Interpreted |
| Mercury (Hg) | max. 0.1 ppm | 0.005 ppm | Cold-vapour AAS / ICP-MS | Interpreted |
Specification values are guaranteed limits. Typical values are representative of production lots and are not guaranteed. Lot-specific certificates of analysis ship with every order.
| Grade | Concentration | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade ACS | 80% | — | current | current |
| Technical | 80% | — | sodium-chlorite-80-technical | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
| Property | Value | Source |
|---|---|---|
| Appearance | White flakes / powder | Supplier specification |
| pH | 10 - 11 | Supplier specification |
Oxidizer — decomposition rate and gas-evolution data may apply. Consult the SDS for material-of-construction guidance under shipping and storage conditions.
| Material | Rating | Max T (°C) | Notes | Source |
|---|---|---|---|---|
Buna-N (NBR) elastomer | Not recommended | — | Rapid degradation; never use with oxidizers. | Parker O-ring Chemical Compatibility |
EPDM elastomer | Good | 40 | Preferred elastomer for H2O2 service | Solvay H2O2 Safety & Handling |
Viton (FKM) elastomer | Poor | — | Use EPDM or PTFE for sealing | Solvay H2O2 Safety & Handling |
PTFE fluoropolymer | Excellent | 200 | Universal compatibility; preferred lining material. | Cole-Parmer Chemical Compatibility |
PVDF fluoropolymer | Excellent | 80 | Preferred fluoropolymer for piping | Solvay H2O2 Safety & Handling |
Borosilicate Glass glass ceramic | Excellent | 100 | Inert to all oxidizers within normal service temperatures. | Cole-Parmer Chemical Compatibility |
Concrete (untreated) glass ceramic | Not recommended | — | Reactive; line with HDPE/FRP | Solvay H2O2 Safety & Handling |
304 stainless steel metal | Good | 40 | May darken; acceptable for short-term storage | Solvay H2O2 Safety & Handling |
316 stainless steel metal | Excellent | 40 | Passivated surfaces preferred | Solvay H2O2 Safety & Handling |
Aluminium 1100/3003 metal | Good | 40 | Limit to dilute service | Solvay H2O2 Safety & Handling |
Brass metal | Not recommended | — | Copper-induced decomposition | Solvay H2O2 Safety & Handling |
Carbon Steel metal | Not recommended | — | Rapid corrosion; never use with oxidizers. | Cole-Parmer Chemical Compatibility |
Copper metal | Not recommended | — | Catalytic decomposition; severe | Solvay H2O2 Safety & Handling |
CPVC thermoplastic | Good | 60 | Acceptable to 60 °C | Solvay H2O2 Safety & Handling |
HDPE thermoplastic | Good | 50 | Concentrations ≤ 50%; vented containers only | Solvay H2O2 Safety & Handling |
PVC thermoplastic | Fair | 40 | Embrittlement risk above 40 °C | Solvay H2O2 Safety & Handling |
Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.
Showing 16 of 16 materials compatible at the selected envelope.
| Material | Rating | Max T (°C) | Notes |
|---|---|---|---|
Buna-N (NBR) elastomer | Not recommended | — | Rapid degradation; never use with oxidizers. |
EPDM elastomer | Good | 40 | Preferred elastomer for H2O2 service |
Viton (FKM) elastomer | Poor | — | Use EPDM or PTFE for sealing |
PTFE fluoropolymer | Excellent | 200 | Universal compatibility; preferred lining material. |
PVDF fluoropolymer | Excellent | 80 | Preferred fluoropolymer for piping |
Borosilicate Glass glass ceramic | Excellent | 100 | Inert to all oxidizers within normal service temperatures. |
Concrete (untreated) glass ceramic | Not recommended | — | Reactive; line with HDPE/FRP |
304 stainless steel metal | Good | 40 | May darken; acceptable for short-term storage |
316 stainless steel metal | Excellent | 40 | Passivated surfaces preferred |
Aluminium 1100/3003 metal | Good | 40 | Limit to dilute service |
Brass metal | Not recommended | — | Copper-induced decomposition |
Carbon Steel metal | Not recommended | — | Rapid corrosion; never use with oxidizers. |
Copper metal | Not recommended | — | Catalytic decomposition; severe |
CPVC thermoplastic | Good | 60 | Acceptable to 60 °C |
HDPE thermoplastic | Good | 50 | Concentrations ≤ 50%; vented containers only |
PVC thermoplastic | Fair | 40 | Embrittlement risk above 40 °C |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Sodium Chlorite Flakes 80% - ACS Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Sodium Chlorite Flakes 80% - ACS Grade (ACS) is supplied for applications where controlled, selective oxidation is required. Grade selection drives the choice between bulk industrial oxidation, electronics/semiconductor cleaning, and pharmaceutical-grade disinfection.
Materials of construction must be rated for the concentration and temperature in service. Avoid contact with reducing agents, transition metals, and organic combustibles.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
UN1496, Sodium chlorite, 5.1, PG II
Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-07-17 by Andre Taki, DOT Hazmat Specialist.
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.4 | 2026-08-19 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.3 | 2026-08-05 | Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.2 | 2026-07-22 | Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.1 | 2026-07-17 | Canonical data re-verified: 5 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.