Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Sodium Hypochlorite 6%

Technical · 6%

CAS Number
7681-52-9
Alliance Code
sodium-hypochlorite-6
Generated
2026-08-31
Revision
1.5
Reviewed
2026-07-17 · Andre Taki
2D chemical structure of Sodium Hypochlorite 6%
Structure · PubChem
Last reviewed 2026-07-17 by Andre Taki, DOT Hazmat Specialist.

Identity & Composition

Product Name
Sodium Hypochlorite 6%
Alliance Code
sodium-hypochlorite-6
Grade
Technical
Concentration
6%
CAS Number
7681-52-9PubChem
Formula
ClNaOPubChem
Molecular Weight
74.44PubChem
Product Type
solution

Specifications

TestSpecificationTypicalMethodSource
Assay6 % Min6 %Supplier specification
Copper< 0.24 ppm0.024 ppmDerived by dilution
Available Chlorine (Cl2), %5.0 - 6.05.5Supplier specification
Iron1.00 ppm max0.072 ppmSupplier specification
Manganese (Mn)0.002 % Max0.00001 %Supplier specification
Nickel0.50 ppm max0.038 ppmSupplier specification
Sodium Hydroxide (NaOH), %0.1 - 0.2%0.15 %Supplier specification
Sodium Hypochlorite (NaOCl), %5.1 - 6.05.55Supplier specification
Bromate (12.5% Basis)19 ppm max1.8 ppmDerived by dilution
Chlorate (12.5% Basis)1714 ppm max530 ppmDerived by dilution
Cobalt (Co)0.048 ppm max0.0058 ppmDerived by dilution
Insolubles0.072 wt% max0.0072 wt%Derived by dilution
Chlorate (ClO3)1440 mg/l max576 mg/lIon chromatography, EPA 300.1Derived by dilution

Specification values are guaranteed limits. Typical values are representative of production lots and are not guaranteed. Lot-specific certificates of analysis ship with every order.

Available GradesSame CAS, alternate grades and concentrations

GradeConcentrationTypical AssaySKUTDS
This grade Technical6%currentcurrent
Technical12.5%sodium-hypochlorite-12-5View TDS →
Technical8.25%sodium-hypochlorite-8-25View TDS →
Technical5.25%sodium-hypochlorite-5-25View TDS →
Technical3%sodium-hypochlorite-3View TDS →
Technical2%sodium-hypochlorite-2View TDS →
Technical1%sodium-hypochlorite-1View TDS →
Technicalsodium-hypochlorite-10View TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

Physical & Chemical Properties

PropertyValueSource
ColorClearSupplier specification
pH12.0 - 13.0Interpreted
Specific Gravity (20 °C)1.08 - 1.11Supplier specification

Oxidizer — decomposition rate and gas-evolution data may apply. Consult the SDS for material-of-construction guidance under shipping and storage conditions.

Materials of ConstructionService envelope ≈ 6%

MaterialRatingMax T (°C)NotesSource
Buna-N (NBR)
elastomer
Not recommendedRapid degradation; never use with oxidizers.Parker O-ring Chemical Compatibility
EPDM
elastomer
Fair60Service below 35 %; swelling and embrittlement above.Parker O-ring Chemical Compatibility
Viton (FKM)
elastomer
PoorUse EPDM or PTFE for sealingSolvay H2O2 Safety & Handling
PTFE
fluoropolymer
Excellent200Universal compatibility; preferred lining material.Cole-Parmer Chemical Compatibility
PVDF (Kynar)
fluoropolymer
Excellent100Standard for high-purity peroxide service.Solvay H2O2 Materials of Construction
Borosilicate Glass
glass ceramic
Excellent100Inert to all oxidizers within normal service temperatures.Cole-Parmer Chemical Compatibility
Concrete (untreated)
glass ceramic
Not recommendedReactive; line with HDPE/FRPSolvay H2O2 Safety & Handling
304 Stainless Steel
metal
Fair40Surface oxidation at higher concentrations; passivate before service.Cole-Parmer Chemical Compatibility
316L Stainless Steel
metal
Good60Passive layer stable; avoid prolonged service above 60 °C.Solvay H2O2 Materials of Construction
Aluminium 1100/3003
metal
Good40Limit to dilute serviceSolvay H2O2 Safety & Handling
Brass
metal
Not recommendedCopper-induced decompositionSolvay H2O2 Safety & Handling
Carbon Steel
metal
Not recommendedRapid corrosion; never use with oxidizers.Cole-Parmer Chemical Compatibility
Copper
metal
Not recommendedCatalytic decomposition; severeSolvay H2O2 Safety & Handling
CPVC
thermoplastic
Good60Acceptable to 60 °CSolvay H2O2 Safety & Handling
HDPE
thermoplastic
Good25Good below 25 °C; reaction with peroxides accelerates at higher T.Cole-Parmer Chemical Compatibility
Polypropylene
thermoplastic
Good25Service below 35 % at ambient; avoid above 25 °C.Cole-Parmer Chemical Compatibility
PVC
thermoplastic
Fair40Embrittlement risk above 40 °CSolvay H2O2 Safety & Handling

Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.

Materials Selection Tool

Showing 17 of 17 materials compatible at the selected envelope.

MaterialRatingMax T (°C)Notes
Buna-N (NBR)
elastomer
Not recommendedRapid degradation; never use with oxidizers.
EPDM
elastomer
Fair60Service below 35 %; swelling and embrittlement above.
Viton (FKM)
elastomer
PoorUse EPDM or PTFE for sealing
PTFE
fluoropolymer
Excellent200Universal compatibility; preferred lining material.
PVDF (Kynar)
fluoropolymer
Excellent100Standard for high-purity peroxide service.
Borosilicate Glass
glass ceramic
Excellent100Inert to all oxidizers within normal service temperatures.
Concrete (untreated)
glass ceramic
Not recommendedReactive; line with HDPE/FRP
304 Stainless Steel
metal
Fair40Surface oxidation at higher concentrations; passivate before service.
316L Stainless Steel
metal
Good60Passive layer stable; avoid prolonged service above 60 °C.
Aluminium 1100/3003
metal
Good40Limit to dilute service
Brass
metal
Not recommendedCopper-induced decomposition
Carbon Steel
metal
Not recommendedRapid corrosion; never use with oxidizers.
Copper
metal
Not recommendedCatalytic decomposition; severe
CPVC
thermoplastic
Good60Acceptable to 60 °C
HDPE
thermoplastic
Good25Good below 25 °C; reaction with peroxides accelerates at higher T.
Polypropylene
thermoplastic
Good25Service below 35 % at ambient; avoid above 25 °C.
PVC
thermoplastic
Fair40Embrittlement risk above 40 °C

Regulatory & Transport

DOT / 49 CFR

UN Number
UN1791Adjudicated
Hazard Class
8Adjudicated
Packing Group
IIIAdjudicated
Proper Shipping Name
Hypochlorite solutionsAdjudicated

GHS / OSHA HazCom 2012

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
EUH031, H290, H314, H400, H410Adjudicated
P-Codes (Precautionary Statements)
P234, P260, P264, P273, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
no canonical
ACGIH TLV
no canonical
NIOSH REL
no canonical
NIOSH IDLH
no canonical

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Sodium Hypochlorite 6%. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Application Guidance

Sodium Hypochlorite 6% (Technical) is supplied for applications where controlled, selective oxidation is required. Grade selection drives the choice between bulk industrial oxidation, electronics/semiconductor cleaning, and pharmaceutical-grade disinfection.

  • Pulp and textile bleaching
  • Wastewater treatment and odor control
  • Etching and surface cleaning (electronics-grade only)
  • Disinfection and sterilization (food/pharma-grade only)
  • Chemical synthesis and polymerization initiation

Materials of construction must be rated for the concentration and temperature in service. Avoid contact with reducing agents, transition metals, and organic combustibles.

Storage & Handling

Recommended Storage
Cool, well-ventilated area, away from heat, sunlight, and combustibles. Vented containers only — pressure may develop from slow decomposition. Original sealed containers; segregate from organics, metals (especially copper, iron, manganese), and reducing agents.Class-level guidance — not product-specific; the SDS controls.
Handling Precautions
Use PPE including face shield, chemical-resistant gloves, and apron. Avoid contamination — never return unused material to the original container. Ground all transfer equipment.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Combustible materials, organic compounds, reducing agents, transition metal salts (catalytic decomposition), strong bases.Class-level guidance — not product-specific; the SDS controls.
Shelf Life
6 months from date of manufacture in sealed, original packaging

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1791, Hypochlorite solutions, 8, PG III

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
65
Placard
Corrosive
Packing Group
PG III

Revision History

Last reviewed 2026-07-17 by Andre Taki, DOT Hazmat Specialist.

VersionDateChangeTrigger
1.52026-08-12Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-08-05Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • unNumber· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 6 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • packingGroup· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.22026-07-17Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.