Industrial chemicals · Taylor, TX
Technical Data Sheet

Feuille de données techniques

30% Propylene Glycol Technical Grade

Technical Grade · 30%

Numéro CAS
57-55-6
Code Alliance
30-propylene-glycol-technical-grade
Généré le
2026-09-11
Révision
1.3
Vérifié
2026-07-16 · Andre Taki
2D chemical structure of 30% Propylene Glycol Technical Grade
Structure · PubChem
Dernière révision le 2026-07-16 par Andre Taki, DOT Hazmat Specialist.

Identité et composition

Nom du produit
30% Propylene Glycol Technical Grade
Code Alliance
30-propylene-glycol-technical-grade
Qualité
Technical Grade
Concentration
30%
Numéro CAS
57-55-6PubChem
Formule
C3H8O2PubChem
Masse molaire
76.09PubChem
Type de produit
mixture

Spécifications

EssaiSpécificationTypiqueMéthodeSource
Assay29.0 - 31.0 %, by volume30.0 %Interpreted
Propylene glycol concentration29.0 - 31.0 % v/v30.0 %Interpreted
Dilution water quality (conductivity @ 25 °C)Deionized water; ≤ 10 µS/cm1.0ASTM D1125Interpreted
Dipropylene glycol (DPG)0.15 wt% max0.075 wt%GC area % (ASTM E202)Interpreted
Acidity as Acetic Acid0.0015 % max0.00046 %Interpreted
Chlorides as Cl0.58 ppm max0.12 ppmInterpreted
Heavy Metals as Pb1.5 ppm max0.061 ppmInterpreted
Iron0.31 ppm max0.031 ppmInterpreted
ash0.0015% max0.00024 %Interpreted
Suspended MatterPassPasses testInterpreted
Composition30 % propylene glycol / 70 % deionized water, by volumeConformsBy formulation; confirmed by specific gravityInterpreted
Freeze point8.4 °F (-13.1 °C) max8.4 °F (-13.1 °C)ASTM D1177Interpreted

Les valeurs de spécification sont des limites garanties. Les valeurs typiques représentent les lots de production et ne sont pas garanties. Un certificat d'analyse propre au lot accompagne chaque commande.

Qualités disponiblesMême CAS, qualités et concentrations alternatives

QualitéConcentrationTitre typiqueSKUTDS
Cette qualité Technical Grade30%actuelactuel
Technical30%30-propylene-glycol-inhibitedVoir la TDS →
USP Grade30%30-propylene-glycol-usp-gradeVoir la TDS →

Le titre typique indiqué correspond à la moyenne sur fenêtre glissante des lots les plus récents du produit apparenté. Le choix de la qualité conditionne l'utilisation finale en aval — vérifiez que la qualité apparentée correspond à votre spécification avant toute substitution.

Propriétés physiques et chimiques

PropriétéValeurSource
AspectPassInterpreted
Couleur10 APHA (maximum)Interpreted
OdeurMild, characteristicPublished reference
pHEssentially neutral (unbuffered blend)Published reference
Densité relative (20 °C)1.031 (20 °C)Published reference
Masse volumique1.031 g/mL at 20 °CPublished reference
Point d'ébullition~102 °CPublished reference
Point de fusion-13 °C (freeze / crystallization onset)Published reference
Point d'éclairNot flammable (aqueous solution)Published reference
Solubilité (eau)Miscible with waterPublished reference

Réglementation et transport

DOT / 49 CFR

Numéro ONU
Non réglementéAdjudicated
Classe de danger
Non réglementéAdjudicated
Groupe d'emballage
Non réglementéAdjudicated
Désignation officielle de transport
Non réglementéAdjudicated

SGH / OSHA HazCom 2012

Mention d'avertissement
Non réglementéAdjudicated
Codes H (mentions de danger)
Sans objetECHA CLP Annex VI
Codes P (conseils de prudence)
Sans objetECHA CLP Annex VI

Limites d'exposition professionnelle

OSHA PEL (29 CFR 1910.1000)
no canonical
ACGIH TLV
no canonical
NIOSH REL
no canonical
NIOSH IDLH
no canonical

Les descriptions de transport reflètent la consultation du 49 CFR 172.101 au moment de la publication. Données sources : annexe VI du règlement CLP de l'ECHA pour les classifications harmonisées, NIOSH Pocket Guide pour REL/IDLH, tables Z de l'OSHA pour PEL. Vérifiez toujours par rapport au texte réglementaire le plus récent avant toute décision critique pour l'expédition.

Dossier de qualification fournisseur

Un téléchargement compressé unique contenant la FTP, la FDS, le CdA du dernier lot (le cas échéant) et une Lettre de garantie continue récente pour 30% Propylene Glycol Technical Grade. Chaque fichier inclus est haché en SHA-256 et répertorié dans un manifeste vérifiable par votre équipe AQ.

Télécharger le dossier d'audit

Conseils d'application

30% Propylene Glycol Technical Grade (Technical Grade) is a glycol-based heat-transfer and freeze-protection fluid. Concentration sets the freeze and burst protection; the inhibitor package sets how long the system stays protected from corrosion.

  • Closed-loop heat transfer and process cooling
  • Data-centre and chilled-water freeze protection
  • HVAC hydronic loops and glycol makeup
  • Freeze and burst protection for idle or seasonal systems
  • Humectant and carrier applications (USP/food-grade propylene glycol only)

Verify concentration against the required freeze and burst protection, and confirm elastomer and metallurgy compatibility for the service temperature. Ethylene glycol is toxic by ingestion and must not be used where incidental food or potable contact is possible — specify a propylene glycol grade for those services.

Stockage et manipulation

Stockage recommandé
Endroit frais, sec et bien ventilé, dans des contenants d'origine hermétiquement fermés. Les glycols purs sont des liquides combustibles à point d'éclair élevé (environ 99 à 111 °C) et ne nécessitent pas de local à solvants ; les mélanges aqueux n'entretiennent pas la combustion. Protégez les fluides inhibés de toute contamination et du gel en dessous de leur point de protection indiqué.Recommandations par classe — non spécifiques au produit ; la FDS prévaut.
Précautions de manipulation
Gants résistants aux produits chimiques et lunettes de protection. Les qualités d'éthylène glycol sont toxiques par ingestion et doivent être tenues à l'écart des aliments, des boissons et des animaux ; les qualités de propylène glycol ne le sont pas. Évitez le contact avec les surfaces et les équipements chauds. Les additifs inhibiteurs s'épuisent en service — surveillez-les plutôt que de compléter à l'aveugle.Recommandations par classe — non spécifiques au produit ; la FDS prévaut.
Incompatibilités
Oxydants forts, acides forts et bases fortes. Les surfaces galvanisées (zinc) sont attaquées par de nombreux fluides caloporteurs inhibés. Vérifiez la compatibilité des élastomères et des joints pour la température de service ; l'EPDM est la référence pour le service glycol/eau.Recommandations par classe — non spécifiques au produit ; la FDS prévaut.
Durée de conservation
Consulter le Service technique pour la durée de conservation propre au produit

Pour des consignes complètes sur les dangers, les EPI et les interventions d'urgence, se reporter à la fiche de données de sécurité (FDS) de ce produit. La FDS prévaut en cas de divergence.

Conditionnement et logistique

Désignation d'expédition (US DOT)

Non réglementé pour le transport.

Vérifiez auprès des documents d'expédition et des exigences du transporteur avant la remise au transporteur.

Classe NMFC
55

Historique des révisions

Dernière révision le 2026-07-16 par Andre Taki, DOT Hazmat Specialist.

VersionDateModificationDéclencheur
1.32026-09-09Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • physicalProperties· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-24Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • physicalProperties· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-16Canonical data re-verified: 4 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • dotSubsidiaryHazardClass· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • physicalProperties· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

Cette fiche technique est fournie à titre de référence technique. La fiche de données de sécurité (FDS) prévaut dans tous les cas où les indications diffèrent. Les valeurs reflètent les données canoniques d'Alliance Chemical au moment de la génération ; les révisions ultérieures sont consignées dans l'historique des révisions ci-dessus.