Sample Certificate of Analysis
ACS Reagent
Sample COA. Contact Alliance Chemical with your lot number to request a lot-specific COA.
Sample specification reference for Petroleum Ether ACS Reagent Grade. Source-record results are reference values, not measurements for your lot.
| Parameter | Specification | Source reference result | Test Method |
|---|---|---|---|
| Acidity | To pass test | Passes test | — |
| Benzene (GC) | max 2 ppm | 0.15 wt ppm | GC |
| Color (APHA) | max 10 | 5 | — |
| Copper Corrosion | To Pass | Passes test | — |
| Doctor Test | negative | Passes test | — |
| Residue After Evaporation | max. 10 ppm | 2 ppm | — |
| Substances darkened by sulfuric acid | Passes test | Passes test | — |
| Sulphur compounds (as S) | max. 0.005 % | 0.00020 % | — |
| Water | 0.02% max. | 0.003 % | Coulometry |
| Boiling range | 35.0-60.0 C | 46.2 C | — |
| Specific gravity @ 20/20 °C | 0.640 - 0.660 | 0.650 | ASTM D4052 / digital density meter |
| Identification (GC-FID) | Conforms to reference chromatogram | Passes test | GC-FID retention profile vs. reference standard |
Specification limits and source-record results are reproduced from the current product reference used by the TDS. This sample is not an issued certificate and does not identify a tested lot. Contact Alliance Chemical with the product and lot number for lot-specific documentation.
容器のラベルに記載されたロット番号をお知らせいただければ、無料で証明書をお送りします。