Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Hydrogen Peroxide 35%

35%

Alliance Code
SHOPIFY-8019789545514
確認日
2026-10-13
Revision
1.4
CAS番号
7722-84-1
UN番号
UN2014
危険有害性クラス・容器等級
5.1 · PG II
構造
2D chemical structure of Hydrogen Peroxide 35%
構造・PubChem
グレード
35%
注意喚起語
Danger
危険有害性
酸化剤腐食性刺激性 / 有害性H272 H302 H314 H332 H335
正式輸送品名
Hydrogen peroxide, aqueous solutions with not less than 20 percent but not more than 40 percent hydrogen peroxide (stabilized as necessary)
Last reviewed 2026-10-13.

Identity & Composition

製品名
Hydrogen Peroxide 35%
Alliance Code
SHOPIFY-8019789545514
グレード
—
濃度
35%
CAS番号
7722-84-1Adjudicated
化学式
H2O2Adjudicated
分子量
34.015Adjudicated
製品種別
Solution

Specifications

Not yet characterized — Specification limits for this product have not been published yet. Contact Technical Services for the current specification and available lot-specific documentation.

Available GradesSame CAS, alternate grades and concentrations

グレード濃度Typical AssaySKUTDS
This grade —35%—currentcurrent
ACS Grade30%—hydrogen-peroxide-30-acs-gradeView TDS →
ACS Grade25%—hydrogen-peroxide-25-acs-gradeView TDS →
Technical Grade25%—hydrogen-peroxide-25-technical-gradeView TDS →
ACS Grade15%—hydrogen-peroxide-15-acs-gradeView TDS →
Technical Grade15%—hydrogen-peroxide-15-technical-gradeView TDS →
ACS Grade12%—hydrogen-peroxide-12-acs-gradeView TDS →
ACS Grade10%—hydrogen-peroxide-10-acs-gradeView TDS →
Technical Grade10%—hydrogen-peroxide-10-technical-gradeView TDS →
Technical Grade6%—hydrogen-peroxide-6-technical-gradeView TDS →
ACS Grade5%—hydrogen-peroxide-5-acs-gradeView TDS →
Technical Grade5%—hydrogen-peroxide-5-technical-gradeView TDS →
Technical Grade3%—hydrogen-peroxide-3-technical-gradeView TDS →

各グレードの代表的な含量は、直近ロットの平均値です。代替品として使用する前に、そのグレードがお客様の仕様を満たしていることをご確認ください。

物理的及び化学的性質

Property値Source
外観Clear, colorless liquidAdjudicated

Oxidizer — decomposition rate and gas-evolution data may apply. Consult the SDS for material-of-construction guidance under shipping and storage conditions.

Property Curves

密度 vs. Temperature (35%)
1.111.121.131.140102030405060Temperature (°C)密度 (g/cm³)

Source: Solvay H2O2 Properties (35% reference)

蒸気圧 vs. Temperature (35%)
0.0050.010015020020304050607080Temperature (°C)蒸気圧 (mmHg)

Source: Solvay H2O2 Properties (35% reference)

Reference curves drawn from public engineering data. For engineering use, consult the cited source for the underlying tabulated values.

Materials of ConstructionService envelope ≈ 35%

MaterialRatingMax T (°C)NotesSource
Buna-N (NBR)
elastomer
Not recommended—Rapid degradation; never use with oxidizers.Parker O-ring Chemical Compatibility
EPDM
elastomer
Fair60Service below 35 %; swelling and embrittlement above.Parker O-ring Chemical Compatibility
Viton (FKM)
elastomer
Poor—Use EPDM or PTFE for sealingSolvay H2O2 Safety & Handling
PTFE
fluoropolymer
Excellent200Universal compatibility; preferred lining material.Cole-Parmer Chemical Compatibility
PVDF (Kynar)
fluoropolymer
Excellent100Standard for high-purity peroxide service.Solvay H2O2 Materials of Construction
Borosilicate Glass
glass ceramic
Excellent100Inert to all oxidizers within normal service temperatures.Cole-Parmer Chemical Compatibility
Concrete (untreated)
glass ceramic
Not recommended—Reactive; line with HDPE/FRPSolvay H2O2 Safety & Handling
304 Stainless Steel
metal
Fair40Surface oxidation at higher concentrations; passivate before service.Cole-Parmer Chemical Compatibility
316L Stainless Steel
metal
Good60Passive layer stable; avoid prolonged service above 60 °C.Solvay H2O2 Materials of Construction
Aluminium 1100/3003
metal
Good40Limit to dilute serviceSolvay H2O2 Safety & Handling
Brass
metal
Not recommended—Copper-induced decompositionSolvay H2O2 Safety & Handling
Carbon Steel
metal
Not recommended—Rapid corrosion; never use with oxidizers.Cole-Parmer Chemical Compatibility
Copper
metal
Not recommended—Catalytic decomposition; severeSolvay H2O2 Safety & Handling
CPVC
thermoplastic
Good60Acceptable to 60 °CSolvay H2O2 Safety & Handling
HDPE
thermoplastic
Good25Good below 25 °C; reaction with peroxides accelerates at higher T.Cole-Parmer Chemical Compatibility
Polypropylene
thermoplastic
Good25Service below 35 % at ambient; avoid above 25 °C.Cole-Parmer Chemical Compatibility
PVC
thermoplastic
Fair40Embrittlement risk above 40 °CSolvay H2O2 Safety & Handling

Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.

Materials Selection Tool

Showing 17 of 17 material ratings within the selected envelope.

MaterialRatingMax T (°C)Notes
Buna-N (NBR)
elastomer
Not recommended—Rapid degradation; never use with oxidizers.
EPDM
elastomer
Fair60Service below 35 %; swelling and embrittlement above.
Viton (FKM)
elastomer
Poor—Use EPDM or PTFE for sealing
PTFE
fluoropolymer
Excellent200Universal compatibility; preferred lining material.
PVDF (Kynar)
fluoropolymer
Excellent100Standard for high-purity peroxide service.
Borosilicate Glass
glass ceramic
Excellent100Inert to all oxidizers within normal service temperatures.
Concrete (untreated)
glass ceramic
Not recommended—Reactive; line with HDPE/FRP
304 Stainless Steel
metal
Fair40Surface oxidation at higher concentrations; passivate before service.
316L Stainless Steel
metal
Good60Passive layer stable; avoid prolonged service above 60 °C.
Aluminium 1100/3003
metal
Good40Limit to dilute service
Brass
metal
Not recommended—Copper-induced decomposition
Carbon Steel
metal
Not recommended—Rapid corrosion; never use with oxidizers.
Copper
metal
Not recommended—Catalytic decomposition; severe
CPVC
thermoplastic
Good60Acceptable to 60 °C
HDPE
thermoplastic
Good25Good below 25 °C; reaction with peroxides accelerates at higher T.
Polypropylene
thermoplastic
Good25Service below 35 % at ambient; avoid above 25 °C.
PVC
thermoplastic
Fair40Embrittlement risk above 40 °C

Regulatory & Transport

DOT / 49 CFR

国連番号
UN2014Adjudicated
危険有害性クラス
5.1Adjudicated
容器等級
IIAdjudicated
正式輸送品名
Hydrogen peroxide, aqueous solutions with not less than 20 percent but not more than 40 percent hydrogen peroxide (stabilized as necessary)Adjudicated

GHS / OSHA HCS 2024

注意喚起語
DangerAdjudicated
H-Codes (Hazard Statements)
H272, H302, H314, H332, H335Adjudicated
P-Codes (Precautionary Statements)
P210, P220, P260, P261, P264, P270, P271, P280, P301+P312, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P312, P321, P330, P363, P370+P378, P403+P233, P405, P501Adjudicated

許容濃度

OSHA PEL (29 CFR 1910.1000)
1 ppm TWAOSHA 29 CFR 1910.1000
ACGIH TLV
—no canonical
NIOSH REL
1 ppm TWANIOSH Pocket Guide
NIOSH IDLH
75 ppmNIOSH Pocket Guide

輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Hydrogen Peroxide 35%. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Application Guidance

Hydrogen Peroxide 35% is supplied for applications where controlled, selective oxidation is required. Grade selection drives the choice between bulk industrial oxidation, electronics/semiconductor cleaning, and pharmaceutical-grade disinfection.

  • Pulp and textile bleaching
  • Wastewater treatment and odor control
  • Etching and surface cleaning (electronics-grade only)
  • Disinfection and sterilization (food/pharma-grade only)
  • Chemical synthesis and polymerization initiation

Materials of construction must be rated for the concentration and temperature in service. Avoid contact with reducing agents, transition metals, and organic combustibles.

Storage & Handling

Recommended Storage
通気口付きの元の容器に入れ、直射日光を避け冷暗所に、可燃物、有機物および金属から遠ざけて保管すること。一度取り出した物質は決して元の容器に戻さないこと。清潔で適合性のある機器(高純度アルミニウム、ステンレス鋼、HDPE、ガラス)のみを使用すること。Adjudicated
Handling Precautions
Use PPE including face shield, chemical-resistant gloves, and apron. Avoid contamination — never return unused material to the original container. Ground all transfer equipment.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
可燃性物質および有機物(紙、木材、油類、アセトンおよびアルコールなどの溶剤);還元剤;金属および金属塩、特に鉄、銅、黄銅および鉛(激しい分解を触媒する);シアン化物および硫化物;強酸および強塩基;アンモニア。Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN2014, Hydrogen peroxide, aqueous solutions with not less than 20 percent but not more than 40 percent hydrogen peroxide (stabilized as necessary), 5.1, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
65
Placard
Oxidizer
容器等級
PG II

Revision History

VersionDateChangeTrigger
1.42026-10-13Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-10-06Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-10-05Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
  • oel_osha_pel· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-09-09Canonical data updated: 14 fields changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
  • signalWord· canonical change (coa.data_provenance / adjudication)
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
  • casNumber· canonical change (coa.data_provenance / adjudication)
  • formula· canonical change (coa.data_provenance / adjudication)
  • molecularWeight· canonical change (coa.data_provenance / adjudication)
  • hsCode· canonical change (coa.data_provenance / adjudication)
  • countryOfOrigin· canonical change (coa.data_provenance / adjudication)
canonical_change

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.