Technical Data Sheet
Technical Grade
| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Glycerol content | 98.0 Min | 99.5 | — | Interpreted |
| Chlorides | 10 ppm Max | 1.5 ppm | — | Interpreted |
| Chlorinated compounds | 30 ppm Max | 5 ppm | — | Interpreted |
| Fatty acid & ester | 1.00 Max | 0.20 | — | Interpreted |
| Glycerol | Min 99.7% | 99.8% | — | Interpreted |
| Heavy metals | 5 ppm Max | 1 ppm | — | Interpreted |
| Organic residue | 2.0% Max | 0.3 % | — | Interpreted |
| Sulfates | Max 20 ppm | 3 ppm | — | Interpreted |
| Water | 0.5 % Max | 0.12 % | — | Interpreted |
| Sulfated ash | 0.01 % Max | 0.003 % | Gravimetric, 600 °C (ASTM D482 style) | Interpreted |
| Diethylene glycol / ethylene glycol (GC) | Not detected (limit 0.1 % each) | Passes test | GC-FID (EP 2.4.30 / glycerin ID B procedure) | Interpreted |
Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.
| Grade | Concentration | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade Technical Grade | — | — | current | current |
| Food | 75% | — | glycerin-75-food-grade | View TDS → |
| Food | 50% | — | glycerin-50-food-grade | View TDS → |
| Food | 25% | — | glycerin-25-food-grade | View TDS → |
| USP Grade | — | — | glycerin-usp-grade | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
| Property | Value | Source |
|---|---|---|
| Appearance | Glycerine appears as a colorless to brown colored liquid. Combustible but may require some effort to ignite. | Published reference |
| Form | Liquid | Published reference |
| Color | 40 Max (Pt - Co) | Interpreted |
| Odor | MILD ODOR | Published reference |
| pH | 4.0 - 9.1 | Interpreted |
| Specific Gravity (20 °C) | Min 1.259 | Interpreted |
| Density | 1.261 at 68 °F (USCG, 1999) - Denser than water; will sink | Published reference |
| Boiling Point | 554 °F at 760 mmHg (decomposes) (NTP, 1992) | Published reference |
| Melting Point | 64 °F (NTP, 1992) | Published reference |
| Flash Point | 320 °F (NTP, 1992) | Published reference |
| Vapor Pressure | 0.0025 mmHg at 122 °F ; 40 mmHg at 388 °F (NTP, 1992) | Published reference |
| Solubility (water) | greater than or equal to 100 mg/mL at 64 °F (NTP, 1992) | Published reference |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Glycerin Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Glycerin Technical Grade (Technical Grade) application guidance is available on request. Contact Alliance Chemical Technical Services for grade-specific use recommendations.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Not regulated for transport.
Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-06-17 by Andre Taki, DOT Hazmat Specialist.
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.1 | 2026-06-17 | Canonical data re-verified: 3 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.