Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Hexane Technical Grade

Technical Grade

CAS Number
110-54-3
Alliance Code
hexane-technical-grade-1
Generated
2026-09-01
Revision
1.3
Reviewed
2026-06-18 · Andre Taki
2D chemical structure of Hexane Technical Grade
Structure · PubChem
Last reviewed 2026-06-18 by Andre Taki, DOT Hazmat Specialist.

Identity & Composition

Product Name
Hexane Technical Grade
Alliance Code
hexane-technical-grade-1
Grade
Technical Grade
Concentration
CAS Number
110-54-3PubChem
Formula
C6H14PubChem
Molecular Weight
86.18PubChem
Product Type
pure_substance

Specifications

TestSpecificationTypicalMethodSource
n-Hexane content44.0 wt% min.61.3 wt%ASTM D5134Supplier specification
Aniline Point, °F140 Min149Supplier specification
API Gravity, @60°F71.0 – 81.076.0Supplier specification
Aromatics by UV10 wppm max.2 wppmAMS_140.31Supplier specification
Bromine Index30 mgBr/100g max.5ASTM D2710Supplier specification
Corrosion, 3 Hrs. @ 122°F1 Max1aSupplier specification
Cyclohexane1.0 wt% max.0.1 wt%ASTM D5134Supplier specification
Doctor TestNegativePasses testSupplier specification
Dry point70.0 °C max.68.8 °CASTM D1078Supplier specification
Hexanes, Total Lv%90.0 Min93.5Supplier specification
Iso Hexanes, %V35.0 Max32.0Supplier specification
Novol. Residue, Mg./100 ml.1 Max0.2Supplier specification
N-Hexane, %V45.0 Min61.5Supplier specification
Nonvolatile Residue0.5 mg/100mL max.0.2 mg/100mLASTM D1353Supplier specification
Total Sulphur1.0 mg/kg max.0.2 mg/kgASTM D5453Supplier specification
Benzene5 wppm max.0.7 wppmGC, ASTM D3606Interpreted

Specification values are guaranteed limits. Typical values are representative of production lots and are not guaranteed. Lot-specific certificates of analysis ship with every order.

Available GradesSame CAS, alternate grades and concentrations

GradeConcentrationTypical AssaySKUTDS
This grade Technical Gradecurrentcurrent
ACS Reagenthexane-acs-reagent-gradeView TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

Physical & Chemical Properties

PropertyValueSource
AppearanceClear/Free/Suspended MatterSupplier specification
FormLiquidPublished reference
Color30 MinSupplier specification
OdorCharacteristicSupplier specification
Specific Gravity (20 °C)0.6659 – 0.6988Supplier specification
Density0.659 at 68 °F (USCG, 1999) - Less dense than water; will floatPublished reference
Boiling Point64.0 °C min.Supplier specification
Melting Point-139 °F (NTP, 1992)Published reference
Flash Point0.0 MaxSupplier specification
Vapor Pressure120 mmHg at 68 °F ; 180 mmHg at 77 °F (NTP, 1992)Published reference
Solubility (water)less than 1 mg/mL at 61.7 °F (NTP, 1992)Published reference

Materials of Construction

MaterialRatingMax T (°C)NotesSource
Buna-N (NBR)
elastomer
Good80Good for non-aromatic hydrocarbons; poor for aromatics.Parker O-ring Chemical Compatibility
EPDM
elastomer
Not recommendedSwells in hydrocarbons; never use.Parker O-ring Chemical Compatibility
Viton (FKM)
elastomer
Excellent100Standard for hydrocarbon service.Parker O-ring Chemical Compatibility
PTFE
fluoropolymer
Excellent200Universal.Cole-Parmer Chemical Compatibility
316L Stainless Steel
metal
Excellent100Inert.Cole-Parmer Chemical Compatibility
Carbon Steel
metal
Good80Acceptable for dry hydrocarbons.Cole-Parmer Chemical Compatibility
HDPE
thermoplastic
Not recommendedAromatic solvents swell and dissolve HDPE.Cole-Parmer Chemical Compatibility

Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.

Materials Selection Tool

Showing 7 of 7 materials compatible at the selected envelope.

MaterialRatingMax T (°C)Notes
Buna-N (NBR)
elastomer
Good80Good for non-aromatic hydrocarbons; poor for aromatics.
EPDM
elastomer
Not recommendedSwells in hydrocarbons; never use.
Viton (FKM)
elastomer
Excellent100Standard for hydrocarbon service.
PTFE
fluoropolymer
Excellent200Universal.
316L Stainless Steel
metal
Excellent100Inert.
Carbon Steel
metal
Good80Acceptable for dry hydrocarbons.
HDPE
thermoplastic
Not recommendedAromatic solvents swell and dissolve HDPE.

Regulatory & Transport

DOT / 49 CFR

UN Number
UN120849 CFR 172.101
Hazard Class
3Adjudicated
Packing Group
IIAdjudicated
Proper Shipping Name
HexanesAdjudicated

GHS / OSHA HazCom 2012

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H225, H304, H315, H336, H361f, H373, H411ECHA CLP Annex VI
P-Codes (Precautionary Statements)
P201, P202, P210, P233, P240, P241, P242, P243, P260, P261, P264, P270, P271, P273, P280, P301+P310, P302+P352, P303+P361+P353, P304+P340, P308+P313, P312, P314, P321, P331, P332+P313, P362, P370+P378, P391, P403+P233, P403+P235, P405, P501ECHA CLP Annex VI

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
500 ppm TWAOSHA 29 CFR 1910.1000
ACGIH TLV
no canonical
NIOSH REL
50 ppm TWANIOSH Pocket Guide
NIOSH IDLH
1100 ppm (10% LEL)NIOSH Pocket Guide

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Hexane Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Sigma-Aldrich

SKUGradeConc.MatchNotes
139386ACS Reagent95%ExactACS Reagent ≥95%

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Application Guidance

Hexane Technical Grade (Technical Grade) is a nonpolar solvent used for hydrocarbon extraction, coatings, and degreasing.

  • Coatings, paints, and adhesives
  • Industrial degreasing
  • Hydrocarbon extraction and recovery
  • Rubber and polymer processing
  • Cleaning of oil-based residues

Highly flammable and electrostatic-prone. Use grounded transfer equipment and inert gas blanketing where appropriate.

Storage & Handling

Recommended Storage
Cool, well-ventilated flammable-liquid storage. Tightly sealed containers. Segregate from oxidizers. Bond and ground bulk storage; consider inert gas blanketing for volatile solvents.Class-level guidance — not product-specific; the SDS controls.
Handling Precautions
Eliminate ignition sources. Use chemical-resistant nitrile or PVA gloves. Bond and ground all transfer equipment. Vapors heavier than air — control ventilation accordingly.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong oxidizers, halogens, nitric acid. Some grades react with rubber and certain plastics — verify gasket and hose compatibility.Class-level guidance — not product-specific; the SDS controls.
Shelf Life
36 monthseamaterials.com

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1208, Hexanes, 3, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
70
Placard
Flammable Liquid
Packing Group
PG II

Revision History

Last reviewed 2026-06-18 by Andre Taki, DOT Hazmat Specialist.

VersionDateChangeTrigger
1.32026-08-05Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
  • signalWord· canonical change (coa.data_provenance / adjudication)
  • unNumber· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-06-18Canonical data re-verified: 3 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.