Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Hydrogen Peroxide 12% Technical Grade

Technical Grade · 12%

Alliance Code
hydrogen-peroxide-12-technical-grade
Reviewed
2026-07-17
Revision
1.7
CAS number
7722-84-1
UN number
UN2984
Hazard class · packing group
5.1 · PG III
Structure
2D chemical structure of Hydrogen Peroxide 12% Technical Grade
Structure · PubChem
Grade
Technical Grade · 12%
Signal word
Danger
Hazards
OxidizerCorrosiveIrritant / harmfulH272 H302 H315 H318
Proper shipping name
Hydrogen peroxide, aqueous solutions with not less than 8 percent but less than 20 percent hydrogen peroxide (stabilized as necessary)
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

Product Name
Hydrogen Peroxide 12% Technical Grade
Alliance Code
hydrogen-peroxide-12-technical-grade
Grade
Technical Grade
Concentration
12%
CAS Number
7722-84-1PubChem
Formula
H2O2PubChem
Molecular Weight
—PubChem
Product Type
Solution

Specifications

TestSpecificationTypicalMethodSource
Assay (H2O2)11.5 - 12.5 %11.98 %—Interpreted
Water87.5 - 88.5 wt%88.01 wt%Calculated by difference (100 - assay - nonvolatiles); KF titration not valid in a peroxide matrixInterpreted
Chloride (Cl)4.2ppm max0.29 ppm—Interpreted
Heavy Metals (as Pb)2ppm max0.088 ppm—Interpreted
Iron (Fe)2ppm max0.062 ppm—Interpreted
Evaporation Residue0.02% max0.0099 %—Interpreted
Composition12 % hydrogen peroxide in deionized water, by weightConformsBy formulation; confirmed by specific gravityInterpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

Available GradesSame CAS, alternate grades and concentrations

GradeConcentrationTypical AssaySKUTDS
This grade Technical Grade12%—currentcurrent
—35%—SHOPIFY-8019789545514View TDS →
ACS Grade30%—hydrogen-peroxide-30-acs-gradeView TDS →
Technical Grade25%—hydrogen-peroxide-25-technical-gradeView TDS →
ACS Grade15%—hydrogen-peroxide-15-acs-gradeView TDS →
Technical Grade15%—hydrogen-peroxide-15-technical-gradeView TDS →
ACS Grade12%—hydrogen-peroxide-12-acs-gradeView TDS →
ACS Grade10%—hydrogen-peroxide-10-acs-gradeView TDS →
Technical Grade10%—hydrogen-peroxide-10-technical-gradeView TDS →
Technical Grade6%—hydrogen-peroxide-6-technical-gradeView TDS →
ACS Grade5%—hydrogen-peroxide-5-acs-gradeView TDS →
Technical Grade5%—hydrogen-peroxide-5-technical-gradeView TDS →
Technical Grade3%—hydrogen-peroxide-3-technical-gradeView TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

Physical & Chemical Properties

PropertyValueSource
AppearanceClear, colorless liquidAdjudicated
FormLiquidPublished reference
OdorOdorless to faintly sharpAdjudicated
pH2–4 at 20 °CAdjudicated
Specific Gravity1.036–1.046 at 20 °C (water = 1)Adjudicated
Density1.04 (12% w/w aqueous solution, 20 °C)Published reference
Boiling PointApprox. 102 °C (216 °F) (calculated for this solution)Adjudicated
Melting PointApprox. −7.5 °C (19 °F), freezing point (calculated for this solution)Adjudicated
Flash PointNot applicableAdjudicated
Vapor PressureApprox. 16–17 mmHg at 20 °C (mostly water vapor)Adjudicated
Solubility (water)Completely miscible with waterAdjudicated

Oxidizer — decomposition rate and gas-evolution data may apply. Consult the SDS for material-of-construction guidance under shipping and storage conditions.

Materials of ConstructionService envelope ≈ 12%

MaterialRatingMax T (°C)NotesSource
Buna-N (NBR)
elastomer
Not recommended—Rapid degradation; never use with oxidizers.Parker O-ring Chemical Compatibility
EPDM
elastomer
Fair60Service below 35 %; swelling and embrittlement above.Parker O-ring Chemical Compatibility
Viton (FKM)
elastomer
Poor—Use EPDM or PTFE for sealingSolvay H2O2 Safety & Handling
PTFE
fluoropolymer
Excellent200Universal compatibility; preferred lining material.Cole-Parmer Chemical Compatibility
PVDF (Kynar)
fluoropolymer
Excellent100Standard for high-purity peroxide service.Solvay H2O2 Materials of Construction
Borosilicate Glass
glass ceramic
Excellent100Inert to all oxidizers within normal service temperatures.Cole-Parmer Chemical Compatibility
Concrete (untreated)
glass ceramic
Not recommended—Reactive; line with HDPE/FRPSolvay H2O2 Safety & Handling
304 Stainless Steel
metal
Fair40Surface oxidation at higher concentrations; passivate before service.Cole-Parmer Chemical Compatibility
316L Stainless Steel
metal
Good60Passive layer stable; avoid prolonged service above 60 °C.Solvay H2O2 Materials of Construction
Aluminium 1100/3003
metal
Good40Limit to dilute serviceSolvay H2O2 Safety & Handling
Brass
metal
Not recommended—Copper-induced decompositionSolvay H2O2 Safety & Handling
Carbon Steel
metal
Not recommended—Rapid corrosion; never use with oxidizers.Cole-Parmer Chemical Compatibility
Copper
metal
Not recommended—Catalytic decomposition; severeSolvay H2O2 Safety & Handling
CPVC
thermoplastic
Good60Acceptable to 60 °CSolvay H2O2 Safety & Handling
HDPE
thermoplastic
Good25Good below 25 °C; reaction with peroxides accelerates at higher T.Cole-Parmer Chemical Compatibility
Polypropylene
thermoplastic
Good25Service below 35 % at ambient; avoid above 25 °C.Cole-Parmer Chemical Compatibility
PVC
thermoplastic
Fair40Embrittlement risk above 40 °CSolvay H2O2 Safety & Handling

Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.

Materials Selection Tool

Showing 17 of 17 material ratings within the selected envelope.

MaterialRatingMax T (°C)Notes
Buna-N (NBR)
elastomer
Not recommended—Rapid degradation; never use with oxidizers.
EPDM
elastomer
Fair60Service below 35 %; swelling and embrittlement above.
Viton (FKM)
elastomer
Poor—Use EPDM or PTFE for sealing
PTFE
fluoropolymer
Excellent200Universal compatibility; preferred lining material.
PVDF (Kynar)
fluoropolymer
Excellent100Standard for high-purity peroxide service.
Borosilicate Glass
glass ceramic
Excellent100Inert to all oxidizers within normal service temperatures.
Concrete (untreated)
glass ceramic
Not recommended—Reactive; line with HDPE/FRP
304 Stainless Steel
metal
Fair40Surface oxidation at higher concentrations; passivate before service.
316L Stainless Steel
metal
Good60Passive layer stable; avoid prolonged service above 60 °C.
Aluminium 1100/3003
metal
Good40Limit to dilute service
Brass
metal
Not recommended—Copper-induced decomposition
Carbon Steel
metal
Not recommended—Rapid corrosion; never use with oxidizers.
Copper
metal
Not recommended—Catalytic decomposition; severe
CPVC
thermoplastic
Good60Acceptable to 60 °C
HDPE
thermoplastic
Good25Good below 25 °C; reaction with peroxides accelerates at higher T.
Polypropylene
thermoplastic
Good25Service below 35 % at ambient; avoid above 25 °C.
PVC
thermoplastic
Fair40Embrittlement risk above 40 °C

Regulatory & Transport

DOT / 49 CFR

UN Number
UN2984Manual review
Hazard Class
5.1Adjudicated
Packing Group
IIIAdjudicated
Proper Shipping Name
Hydrogen peroxide, aqueous solutions with not less than 8 percent but less than 20 percent hydrogen peroxide (stabilized as necessary)Adjudicated

GHS / OSHA HCS 2024

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H272, H302, H315, H318Adjudicated
P-Codes (Precautionary Statements)
P210, P220, P264, P270, P280, P301+P312, P302+P352, P305+P351+P338, P310, P321, P330, P332+P313, P362, P370+P378, P501Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
1 ppm TWAOSHA 29 CFR 1910.1000
ACGIH TLV
1 ppm TWA (A3: confirmed animal carcinogen with unknown relevance to humans)Adjudicated
NIOSH REL
1 ppm TWANIOSH Pocket Guide
NIOSH IDLH
75 ppmNIOSH Pocket Guide

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Health & Fire Hazard

Acute Toxicology

LD₅₀ Oral (rat)
1,518 mg/kg (8–20% aqueous solution)Adjudicated
LD₅₀ Dermal (rabbit)
2,000–9,200 mg/kg (hydrogen peroxide)Adjudicated
LC₅₀ Inhalation (rat, 4 h)
2 mg/L (2,000 mg/m³) (hydrogen peroxide)Adjudicated

Acute toxicology values from SDS Section 11 or NIOSH RTECS.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Hydrogen Peroxide 12% Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Honeywell

SKUGradeConc.MatchNotes
95302ACS30%Unverified candidateFluka brand, ACS grade

Sigma-Aldrich

SKUGradeConc.MatchNotes
216763ACS Reagent30%Unverified candidateStabilized; ACS Reagent

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Applications

  • Disinfecting surfaces and textileslaballey.com
  • Disinfecting hard surfaces such as tile, countertops, glass and metalslaballey.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
Store in the original vented container, cool and out of sunlight, away from combustibles, organics and metals. Never return material to the container. Use only clean, compatible equipment (high-purity aluminum, stainless steel, HDPE, glass).Adjudicated
Handling Precautions
Use PPE including face shield, chemical-resistant gloves, and apron. Avoid contamination — never return unused material to the original container. Ground all transfer equipment.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Combustible and organic materials (paper, wood, oils, solvents such as acetone and alcohols); reducing agents; metals and metal salts, especially iron, copper, brass and lead (catalyze violent decomposition); cyanides and sulfides; strong acids and bases; ammonia.Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN2984, Hydrogen peroxide, aqueous solutions with not less than 8 percent but less than 20 percent hydrogen peroxide (stabilized as necessary), 5.1, PG III

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
70
Placard
Oxidizer
Packing Group
PG III

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.72026-10-08Canonical data updated: 24 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
  • restrictions_on_use· canonical change (coa.data_provenance / adjudication)
  • odor· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • oel_acgih_tlv· canonical change (coa.data_provenance / adjudication)
  • oel_other· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • decompositionTemperature· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • pH· canonical change (coa.data_provenance / adjudication)
  • specificGravity· canonical change (coa.data_provenance / adjudication)
  • oxidizer_category· canonical change (coa.data_provenance / adjudication)
canonical_change
1.62026-09-30Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-08-04Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
  • hazardClass· canonical change (coa.data_provenance / adjudication)
  • packingGroup· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-07-22Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-07-21Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-17Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 6 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • physicalProperties· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.