Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Nitric Acid 5% Technical Grade

Technical · 5%

Alliance Code
nitric-acid-5
Reviewed
2026-07-17
Revision
1.6
CAS number
7697-37-2
UN number
UN2031
Hazard class · packing group
8 · PG II
Structure
2D chemical structure of Nitric Acid 5% Technical Grade
Structure · PubChem
Grade
Technical · 5%
Signal word
Danger
Hazards
CorrosiveH290 H314
Proper shipping name
Nitric acid, other than red fuming, with not more than 20 percent nitric acid
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

Product Name
Nitric Acid 5% Technical Grade
Alliance Code
nitric-acid-5
Grade
Technical
Concentration
5%
CAS Number
7697-37-2PubChem
Formula
HNO3PubChem
Molecular Weight
—PubChem
Product Type
Solution

Specifications

TestSpecificationTypicalMethodSource
Assay (HNO3)4.5 - 5.5 %5.01 %—Interpreted
Color (APHA)<= 507ASTM D1209, Pt-Co visual comparisonInterpreted
Phosphate (PO4)0.0001 % max0.00000085 %Molybdenum blue colorimetricInterpreted
Substances reducing permanganate (as HNO2)0.000038 % max0.0000060 %Titrimetric, KMnO4 decolorizationInterpreted
Chloride (Cl)1.1 ppm max0.0047 ppm—Interpreted
Iron (Fe)0.78 ppm max0.0019 ppm—Interpreted
Lead (Pb)0.0000013% max0.000000031 %—Interpreted
Residue after Ignition2.6 ppm max0.074 ppm—Interpreted
Sulfates (SO4)1.2 ppm max0.023 ppm—Interpreted
fluoride0.38 ppm max0.0031 ppm—Interpreted
oxides of nitrogen7.7 ppm max0.070 ppm—Interpreted
oxidizable constituents as hno21.2 ppm max0.061 ppm—Interpreted
non-volatiles0.004 % max0.000013 %—Interpreted
Composition5 % nitric acid in deionized water, by weightConformsBy formulation; confirmed by specific gravityInterpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

Available GradesSame CAS, alternate grades and concentrations

GradeConcentrationTypical AssaySKUTDS
This grade Technical5%—currentcurrent
ACS Grade70%—nitric-acid-70-acs-grade-low-particleView TDS →
Technical70%—nitric-acid-70-technical-gradeView TDS →
ACS Grade69%—nitric-acid-acs-69-55-gallon-drumView TDS →
Technical69%—nitric-acid-69-technical-gradeView TDS →
ACS Grade65%—nitric-acid-65View TDS →
Technical65%—nitric-acid-65-technical-gradeView TDS →
Technical40%—nitric-acid-40View TDS →
Technical30%—nitric-acid-30View TDS →
Technical25%—nitric-acid-25View TDS →
Technical20%—nitric-acid-20View TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

Physical & Chemical Properties

PropertyValueSource
AppearanceColorless, fuming liquidAdjudicated
FormLiquidPublished reference
OdorOdorless to slight acrid odorAdjudicated
pH< 1Adjudicated
Specific GravityAbout 1.03 at 20 °C (water = 1)Adjudicated
Density1.025 (5% w/w aqueous solution, 20 °C)Published reference
Boiling Point100 to 101 °C (212 to 214 °F) (aqueous solution)Adjudicated
Melting Point-2.7 to 0 °C (27 to 32 °F), freezing point (aqueous solution)Adjudicated
Flash PointNot applicableAdjudicated
Vapor PressureAbout 17 mmHg at 20 °C (water vapor)Adjudicated
Solubility (water)Completely miscible with waterAdjudicated

Strong acid — density and vapor-pressure values shown are at 20 °C; values shift markedly with concentration and temperature. Reference concentration-temperature curves before specifying equipment.

Materials of Construction

MaterialRatingConditionsSource
chromiumCompatiblehot nitric acid; concentration not stateditwreagents.com

Compatibility is drawn from published manufacturer and supplier documentation for this product; each rating is sourced. Confirm against your specific duty cycle before equipment selection.

Regulatory & Transport

DOT / 49 CFR

UN Number
UN203149 CFR 172.101
Hazard Class
8Adjudicated
Packing Group
IIAdjudicated
Proper Shipping Name
Nitric acid, other than red fuming, with not more than 20 percent nitric acidAdjudicated

GHS / OSHA HCS 2024

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H290, H314Adjudicated
P-Codes (Precautionary Statements)
P234, P260, P264, P280, P301+P330+P331, P303+P361+P353, P304+P340, P305+P351+P338, P310, P321, P363, P390, P405, P406, P501Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
2 ppm TWAOSHA 29 CFR 1910.1000
ACGIH TLV
2 ppm TWA / 4 ppm STEL (nitric acid)Adjudicated
NIOSH REL
2 ppm TWA / 4 ppm STELNIOSH Pocket Guide
NIOSH IDLH
25 ppmNIOSH Pocket Guide

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Nitric Acid 5% Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Catalog EquivalentsCross-reference vs major chemical suppliers

Sigma-Aldrich

SKUGradeConc.MatchNotes
438073ACS Reagent70%Unverified candidateACS Reagent fuming-free 70%

Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.

Applications

  • Used as an etchant and cleaning agentcorecheminc.com
  • Production of fertilizers, dyes, and explosives.itwreagents.com
  • Production of soluble metal nitrates.itwreagents.com
  • Detection of aromatic amino acids and proteins through the xanthoprotein reaction.itwreagents.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
Keep closed in polyethylene, glass or stainless-steel containers, never ordinary metal. Keep away from bases, bleach and organics.Adjudicated
Handling Precautions
Use full PPE including face shield, acid-resistant gloves and apron. Add acid to water slowly with stirring; never reverse. Ventilation required.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Bases (heat); bleach and other hypochlorites (release chlorine); most metals (release hydrogen and nitrogen oxides); cyanides and sulfides (release toxic gases); organic solvents and combustible materials.Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN2031, Nitric acid, other than red fuming, with not more than 20 percent nitric acid, 8, PG II

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
60
Placard
Corrosive
Packing Group
PG II

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.62026-10-07Canonical data updated: 16 fields changed via the provenance/adjudication pipeline.
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
  • restrictions_on_use· canonical change (coa.data_provenance / adjudication)
  • odor· canonical change (coa.data_provenance / adjudication)
  • pH· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • specificGravity· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • oel_acgih_tlv· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
canonical_change
1.52026-09-30Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-08-05Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • unNumber· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-07-22Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-21Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 7 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • dotSubsidiaryHazardClass· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
  • physicalProperties· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.