| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Assay as PG, on a dry basis | 99.50 weight % (minimum) | 99.67 wt.% | — | Interpreted |
| Acidity as Acetic Acid | 0.0050 weight % (maximum) | 0.0017 wt% | — | Interpreted |
| Appearance | Pass | Passes test | — | Interpreted |
| Chlorides as Cl | 1.0 weight ppm (maximum) | 0.51 ppm | — | Interpreted |
| Heavy Metals as Pb | 5 weight ppm (maximum) | 0.27 weight ppm | — | Interpreted |
| Iron | 1.00 weight ppm (maximum) | 0.10 ppm | — | Interpreted |
| Propylene glycol | 99.5 % min. | 99.7 % | ILL-003/3-01-17 | Interpreted |
| Suspended Matter | Pass | Passes test | — | Interpreted |
| Water | 0.200 weight % (maximum) | 0.028 % | — | Interpreted |
| Dipropylene glycol (DPG) | 0.5 wt% Max | 0.27 wt% | GC area % (ASTM E202) | Interpreted |
| ash | 0.005 wt.% max | 0.00056 wt% | — | Interpreted |
Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.
| Grade | Concentration | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade Technical Grade | — | — | current | current |
| — | 60% | — | propylene-glycol-60-inhibited | View TDS → |
| Technical | 60% | — | propylene-glycol-60-technical-grade | View TDS → |
| USP | 60% | — | propylene-glycol-60-usp-grade | View TDS → |
| USP Grade | 50% | — | 50-propylene-glycol-usp-grade | View TDS → |
| Technical Grade | 40% | — | 40-propylene-glycol-technical-grade | View TDS → |
| USP Grade | 40% | — | 40-propylene-glycol-usp-grade | View TDS → |
| — | 20% | — | propylene-glycol-20-inhibited | View TDS → |
| Technical | 20% | — | propylene-glycol-20-technical-grade | View TDS → |
| USP | 20% | — | propylene-glycol-20-usp-grade | View TDS → |
| USP Grade | — | — | propylene-glycol-usp-grade | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
One or more physical-property values are temporarily suppressed pending verification against vendor COA data. For complete properties refer to the Safety Data Sheet (SDS) or contact sales@alliancechemical.com.
| Property | Value | Source |
|---|---|---|
| Appearance | Clear, slightly viscous colorless liquid | Adjudicated |
| Form | Liquid | Published reference |
| Odor | Odorless to mild | Adjudicated |
| Specific Gravity | 1.036–1.040 at 20 °C (water = 1) | Adjudicated |
| Density | 1.035 - 1.038 g/cm3 | Interpreted |
| Boiling Point | 184–188 °C (363–370 °F) | Adjudicated |
| Melting Point | About -60 °C (-76 °F); supercools to a glass rather than crystallizing | Adjudicated |
| Flash Point | 103–107 °C (217–225 °F), closed cup | Adjudicated |
| Vapor Pressure | About 0.1–0.2 mmHg (20–30 Pa) at 25 °C | Adjudicated |
| Solubility (water) | Completely miscible with water | Adjudicated |
| Viscosity | 43–49 mPa·s at 25 °C | Adjudicated |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
Acute toxicology values from SDS Section 11 or NIOSH RTECS.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Propylene Glycol Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Heat-transfer fluid and antifreeze; deicing; solvent and humectant in industrial formulations, resins and coatings.Adjudicated
Restrictions on Use: Technical grade: not for food, drug or cosmetic use.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Not regulated for transport.
Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-06-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.3 | 2026-10-07 | Canonical data updated: 19 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.2 | 2026-09-30 | Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.1 | 2026-06-17 | Canonical data re-verified: 5 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.