Industrial chemicals · Taylor, TX
Technical Data Sheet

Technical Data Sheet

Trichloroethylene (TCE) Technical Grade

Technical Grade

Alliance Code
trichloroethylene-tce-technical-grade
Reviewed
2026-07-17
Revision
1.5
CAS number
79-01-6
UN number
UN1710
Hazard class · packing group
6.1 · PG III
Structure
2D chemical structure of Trichloroethylene (TCE) Technical Grade
Structure · PubChem
Grade
Technical Grade
Signal word
Danger
Hazards
Irritant / harmfulHealth hazardH315 H317 H319 H336 H341 H350 H412
Proper shipping name
Trichloroethylene
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer.

Identity & Composition

Product Name
Trichloroethylene (TCE) Technical Grade
Alliance Code
trichloroethylene-tce-technical-grade
Grade
Technical Grade
Concentration
—
CAS Number
79-01-6PubChem
Formula
C2HCl3PubChem
Molecular Weight
131.38PubChem
Product Type
Pure substance

Specifications

TestSpecificationTypicalMethodSource
Assay (C2HCl3)99.3 % min99.56 %—Interpreted
Acid Acceptance (as NaOH)0.165 % min0.20 %—Interpreted
Titrable base0.0003 meq/g maximum0.000064 meq/g—Interpreted
Distillation Range86.0-90.0 °C87.8 °C—Interpreted
Color (Pt-Co)15 PT-CO max2—Interpreted
Free halogensTO PASS TESTPasses test—Interpreted
Heavy metals (as Pb)1 ppm maximum0.18 ppm—Interpreted
Total Impurities0.20 % max0.037 %—Interpreted
Titrable acid0.0001 meq/g maximum0.000014 meq/g—Interpreted
Non-Volatile Residue0.005 % max0.00075 %—Interpreted
Water (H2O)0.008 % max0.0026 %—Interpreted
1 1 2-trichloroethane0.01 % max0.0016 %—Interpreted
halide0.0005 % max0.000048 %—Interpreted
perchlorethylene0.02 % max0.0039 %—Interpreted

Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.

Available GradesSame CAS, alternate grades and concentrations

GradeConcentrationTypical AssaySKUTDS
This grade Technical Grade——currentcurrent
ACS Grade——trichloroethylene-tce-acs-gradeView TDS →

Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.

Physical & Chemical Properties

PropertyValueSource
AppearanceClear volatile liquidAdjudicated
FormLiquidPublished reference
OdorSweet, ether-like odorAdjudicated
pH9 - 11Interpreted
Specific Gravity1.460-1.467Interpreted
Density1.46 at 68 °F (USCG, 1999) - Denser than water; will sinkPublished reference
Boiling Point87 °C (188 °F) at 760 mmHgAdjudicated
Melting Point-85 °C (-121 °F)Adjudicated
Flash PointNone (does not flash under standard test conditions)Adjudicated
Vapor Pressure58–61 mmHg (7.7–8.1 kPa) at 20 °CAdjudicated
Vapor Density4.5 (air = 1)Adjudicated
Solubility (water)Slightly soluble in water (1.1 g/L at 20 °C)Adjudicated
Viscosity0.55–0.58 mPa·s at 20–25 °CAdjudicated

Regulatory & Transport

DOT / 49 CFR

UN Number
UN1710Adjudicated
Hazard Class
6.1Adjudicated
Packing Group
IIIAdjudicated
Proper Shipping Name
TrichloroethyleneAdjudicated

GHS / OSHA HCS 2024

Signal Word
DangerAdjudicated
H-Codes (Hazard Statements)
H315, H317, H319, H336, H341, H350, H412Adjudicated
P-Codes (Precautionary Statements)
P201, P202, P261, P264, P271, P272, P273, P280, P302+P352, P305+P351+P338, P308+P313, P312, P321, P332+P313, P333+P313, P337+P313, P362, P391, P403+P233, P405, P501Adjudicated

Occupational Exposure Limits

OSHA PEL (29 CFR 1910.1000)
100 ppm TWA / 200 ppm acceptable ceiling / 300 ppm 5-min peakOSHA 29 CFR 1910.1000
ACGIH TLV
10 ppm TWA / 25 ppm STELAdjudicated
NIOSH REL
Ca (carcinogen — minimize occupational exposure)NIOSH Pocket Guide
NIOSH IDLH
1000 ppmNIOSH Pocket Guide

Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.

Health & Fire Hazard

Acute Toxicology

LD₅₀ Oral (rat)
4290–4920 mg/kgAdjudicated
LD₅₀ Dermal (rabbit)
> 20000 mg/kgAdjudicated
LC₅₀ Inhalation (rat, 4 h)
26 mg/LAdjudicated

Acute toxicology values from SDS Section 11 or NIOSH RTECS.

Supplier Qualification Packet

One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Trichloroethylene (TCE) Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.

Download audit packet

Applications

  • Degreaser and industrial solvent; also used in producing fluorocarbon refrigerantssciencelab.com
  • Grade suitable for general industrial usesciencelab.com
  • Solvent used for degreasing, cold cleaning, and specialized industrial applicationschemceed.com
  • Industrial solventsciencelab.com
  • Production of fluorocarbon refrigerantssciencelab.com

Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.

Storage & Handling

Recommended Storage
Store in tightly closed containers in a cool, well-ventilated place, protected from light and moisture. Keep away from strong bases (caustic soda, caustic potash), reactive metals and metal powders.Adjudicated
Handling Precautions
Use standard chemical PPE — splash goggles, gloves, lab coat. Refer to SDS for hazard-specific PPE requirements.Class-level guidance — not product-specific; the SDS controls.
Incompatibilities
Strong bases such as caustic soda and caustic potash (can form spontaneously flammable dichloroacetylene); chemically active metals and metal powders (aluminum, magnesium, zinc, barium, alkali metals); strong oxidizing agents; amines.Adjudicated
Shelf Life
Consult Technical Services for product-specific shelf life

For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.

Packaging & Logistics

Shipping Description (US DOT)

UN1710, Trichloroethylene, 6.1, PG III

Sourced from 49 CFR 172.101. Confirm against shipping documents and carrier requirements before tender.

NMFC Class
70
Placard
Toxic
Packing Group
PG III

Revision History

Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).

VersionDateChangeTrigger
1.52026-10-08Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • ghsClassification· canonical change (coa.data_provenance / adjudication)
  • hazard_h_codes· canonical change (coa.data_provenance / adjudication)
  • hazard_p_codes· canonical change (coa.data_provenance / adjudication)
canonical_change
1.42026-10-05Canonical data updated: 25 fields changed via the provenance/adjudication pipeline.
  • oel_niosh_rel· canonical change (coa.data_provenance / adjudication)
  • oel_idlh· canonical change (coa.data_provenance / adjudication)
  • restrictions_on_use· canonical change (coa.data_provenance / adjudication)
  • tsca_section6_notice· canonical change (coa.data_provenance / adjudication)
  • synonyms· canonical change (coa.data_provenance / adjudication)
  • recommended_use· canonical change (coa.data_provenance / adjudication)
  • odor· canonical change (coa.data_provenance / adjudication)
  • odorThreshold· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • flashPoint· canonical change (coa.data_provenance / adjudication)
  • explosiveLimits· canonical change (coa.data_provenance / adjudication)
  • vaporPressure· canonical change (coa.data_provenance / adjudication)
  • vaporDensity· canonical change (coa.data_provenance / adjudication)
  • solubility· canonical change (coa.data_provenance / adjudication)
  • partitionCoefficient· canonical change (coa.data_provenance / adjudication)
  • viscosity· canonical change (coa.data_provenance / adjudication)
  • storage_precautions· canonical change (coa.data_provenance / adjudication)
  • incompatible_materials· canonical change (coa.data_provenance / adjudication)
  • conditions_to_avoid· canonical change (coa.data_provenance / adjudication)
  • hazardous_decomposition_products· canonical change (coa.data_provenance / adjudication)
  • oel_acgih_tlv· canonical change (coa.data_provenance / adjudication)
  • rcra_waste_codes· canonical change (coa.data_provenance / adjudication)
  • dot_transport_note· canonical change (coa.data_provenance / adjudication)
  • cercla_rq· canonical change (coa.data_provenance / adjudication)
canonical_change
1.32026-09-30Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
  • boilingPoint· canonical change (coa.data_provenance / adjudication)
  • meltingPoint· canonical change (coa.data_provenance / adjudication)
  • appearance· canonical change (coa.data_provenance / adjudication)
canonical_change
1.22026-07-22Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
  • dotSubsidiaryHazardClass· canonical change (coa.data_provenance / adjudication)
  • dotProperShippingName· canonical change (coa.data_provenance / adjudication)
canonical_change
1.12026-07-17Canonical data re-verified: 5 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
  • countryOfOrigin· canonical adjudication / reground (coa.data_provenance)
  • ghsClassification· canonical adjudication / reground (coa.data_provenance)
  • hazard_h_codes· canonical adjudication / reground (coa.data_provenance)
  • hazard_p_codes· canonical adjudication / reground (coa.data_provenance)
  • hsCode· canonical adjudication / reground (coa.data_provenance)
canonical_change
1.02026-05-20Initial URL-first TDS published from canonical chemistry registry.initial

This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.