| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Assay | 39.0 - 41.0 %, by volume | 40.0 % | — | Interpreted |
| Propylene glycol concentration | 39.0 - 41.0 % v/v | 40.0 % | — | Interpreted |
| Dilution water | Purified Water USP; conductivity ≤ 1.3 µS/cm @ 25 °C | Passes test | USP <1231> / conductivity USP <645> | Interpreted |
| Acidity | not more than 0.08 mL of 0.10 N sodium hydroxide | 0.02 | USP monograph titration, 0.10 N NaOH | Interpreted |
| Microbial enumeration | TAMC ≤ 100 CFU/mL; TYMC ≤ 10 CFU/mL | Passes test | USP <61> | Interpreted |
| Chloride | 0.0029% max | 0.000012 % | USP <221> | Interpreted |
| Heavy metals | 2 ppm max | 0.2 ppm | USP <231> | Interpreted |
| Iron | 0.21 ppm max | 0.02 ppm | HOC 0290 | Interpreted |
| Limit of Diethylene Glycol | 0.04% max | 0.0012 % | GC, flame ionization detector, 0.53-mm x 30-m fused-silica G43 column, 2,2,2-trichloroethanol internal standard | Interpreted |
| Limit of Ethylene Glycol | 0.04% max | 0.00081 % | GC, flame ionization detector, 0.53-mm x 30-m fused-silica G43 column, 2,2,2-trichloroethanol internal standard | Interpreted |
| Residue on ignition | 0.0029 wt% max | 0.0002 wt% | Ignition of 50 g, residue moistened with 0.5 mL sulfuric acid and ignited to constant weight | Interpreted |
| Sulfate | 0.0025% max | 0.0002 % | USP <221> | Interpreted |
| arsenic | 0.4 ppm max | 0.0081 ppm | — | Interpreted |
| dpg | 0.04 % max | 0.012 % | — | Interpreted |
| pb | 0.41 mg/kg max | 0.004 mg/kg | — | Interpreted |
| meg | 0.0004 % max | 0.0002 % | — | Interpreted |
| po | 0.0004 % max | 0.000081 % | — | Interpreted |
| tpg | 0.012 % max | 0.0024 % | — | Interpreted |
| residue | 0.002 % max | 0.0004 % | — | Interpreted |
| Identification A (Infrared Absorption) | Infrared Absorption 〈197F〉 on undried specimen | Passes test | USP <197F> | Interpreted |
| Residual solvents | Pass | Passes test | USP <467> | Interpreted |
| Suspended matter | Pass | Passes test | HOC 0171 | Interpreted |
| Composition | 40 % propylene glycol / 60 % deionized water, by volume | Conforms | By formulation; confirmed by specific gravity | Interpreted |
| Freeze point | -6.7 °F (-21.5 °C) max | -6.7 °F (-21.5 °C) | ASTM D1177 | Interpreted |
Specification values are guaranteed limits. Typical values are representative of production lots and are not guaranteed. Lot-specific certificates of analysis ship with every order.
| Grade | 濃度 | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade USP Grade | 40% | — | current | current |
| — | 60% | — | propylene-glycol-60-inhibited | View TDS → |
| Technical | 60% | — | propylene-glycol-60-technical-grade | View TDS → |
| USP | 60% | — | propylene-glycol-60-usp-grade | View TDS → |
| USP Grade | 50% | — | 50-propylene-glycol-usp-grade | View TDS → |
| Technical Grade | 40% | — | 40-propylene-glycol-technical-grade | View TDS → |
| — | 20% | — | propylene-glycol-20-inhibited | View TDS → |
| Technical | 20% | — | propylene-glycol-20-technical-grade | View TDS → |
| USP | 20% | — | propylene-glycol-20-usp-grade | View TDS → |
| Technical Grade | — | — | propylene-glycol-technical-grade | View TDS → |
| USP Grade | — | — | propylene-glycol-usp-grade | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
| Property | 値 | Source |
|---|---|---|
| 外観 | Clear, colorless to pale liquid | Published reference |
| Color | 10 APHA (maximum) | Interpreted |
| 臭い | Pass | Interpreted |
| pH | Essentially neutral (unbuffered blend) | Published reference |
| Specific Gravity (20 °C) | 1.039 (20 °C) | Published reference |
| Density | 1.039 g/mL at 20 °C | Published reference |
| 沸点 | ~104 °C | Published reference |
| 融点 | -22 °C (freeze / crystallization onset) | Published reference |
| 引火点 | Not flammable (aqueous solution) | Published reference |
| Solubility (water) | Miscible with water | Published reference |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: ECHA CLP Annex VI for harmonised classifications, NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Propylene Glycol 40% – USP Grade (C3H8O2). Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Propylene Glycol 40% – USP Grade (C3H8O2) (USP Grade) is a glycol-based heat-transfer and freeze-protection fluid. Concentration sets the freeze and burst protection; the inhibitor package sets how long the system stays protected from corrosion.
Verify concentration against the required freeze and burst protection, and confirm elastomer and metallurgy compatibility for the service temperature. Ethylene glycol is toxic by ingestion and must not be used where incidental food or potable contact is possible — specify a propylene glycol grade for those services.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Not regulated for transport.
Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-07-06 by Andre Taki, DOT Hazmat Specialist.
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.3 | 2026-09-09 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.2 | 2026-07-24 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.1 | 2026-07-06 | Canonical data re-verified: 4 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.