Technical Data Sheet
ACS Grade · 6%
| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Assay (H2O2) | 5.5 - 6.5 % | 6.00 % | — | Interpreted |
| Identification | Passes test | Passes test | Colorimetric - titanium(IV) sulfate / decolorization of acidified KMnO4 | Interpreted |
| Titrable Acid | 0.00012 meq/g max | 0.000039 meq/g | — | Interpreted |
| Ammonium (NH4) | 0.0001 % max | 0.0000085 % | — | Interpreted |
| Chloride (Cl) | 0.72 ppm max | 0.117 ppm | — | Interpreted |
| Heavy Metals (as Pb) | 0.000021 % max | 0.0000022 % | — | Interpreted |
| Iron (Fe) | 0.000011 % max | 0.00000113 % | — | Interpreted |
| Nitrate (NO3) | 0.000072 % max | 0.0000032 % | — | Interpreted |
| Phosphate (PO4) | 0.00012 % max | 0.000011 % | — | Interpreted |
| Residue after Evaporation | 0.00056 % max | 0.00009 % | — | Interpreted |
| Sulfate (SO4) | 0.00018 % max | 0.000020 % | — | Interpreted |
| Color (APHA) | ≤10 | 1 | — | Interpreted |
| Composition | 6 % hydrogen peroxide in deionized water, by weight | Conforms | By formulation; confirmed by specific gravity | Interpreted |
Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.
| グレード | 濃度 | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade ACS Grade | 6% | — | current | current |
| — | 35% | — | SHOPIFY-8019789545514 | View TDS → |
| ACS Grade | 30% | — | hydrogen-peroxide-30-acs-grade | View TDS → |
| ACS Grade | 25% | — | hydrogen-peroxide-25-acs-grade | View TDS → |
| Technical Grade | 25% | — | hydrogen-peroxide-25-technical-grade | View TDS → |
| Technical Grade | 15% | — | hydrogen-peroxide-15-technical-grade | View TDS → |
| ACS Grade | 12% | — | hydrogen-peroxide-12-acs-grade | View TDS → |
| Technical Grade | 12% | — | hydrogen-peroxide-12-technical-grade | View TDS → |
| ACS Grade | 10% | — | hydrogen-peroxide-10-acs-grade | View TDS → |
| Technical Grade | 10% | — | hydrogen-peroxide-10-technical-grade | View TDS → |
| Technical Grade | 6% | — | hydrogen-peroxide-6-technical-grade | View TDS → |
| ACS Grade | 5% | — | hydrogen-peroxide-5-acs-grade | View TDS → |
| Technical Grade | 3% | — | hydrogen-peroxide-3-technical-grade | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
| Property | 値 | Source |
|---|---|---|
| 外観 | Transparent, colorless liquid solution | Adjudicated |
| 形状 | Liquid | Published reference |
| 臭い | Odorless to faintly sharp | Adjudicated |
| pH | Weak acid; H2O2 concn wt% = 35, 50, 70, 90; corresponding true pH: 4.6, 4.3, 4.4, 5.1 | Published reference |
| 比重 | 1.014–1.024 at 20 °C (water = 1) | Adjudicated |
| 密度 | 1.02 (6% w/w aqueous solution, 20 °C) | Published reference |
| 沸点 | 100 °C (212 °F) (aqueous solution) | Adjudicated |
| 融点 | Approx. −3.5 °C (26 °F), freezing point (calculated for this solution) | Adjudicated |
| 引火点 | 該当しない | Adjudicated |
| 蒸気圧 | Approx. 17 mmHg at 20 °C (mostly water vapor) | Adjudicated |
| Solubility (water) | Completely miscible with water | Adjudicated |
Oxidizer — decomposition rate and gas-evolution data may apply. Consult the SDS for material-of-construction guidance under shipping and storage conditions.
| Material | Rating | Max T (°C) | Notes | Source |
|---|---|---|---|---|
Buna-N (NBR) elastomer | Not recommended | — | Rapid degradation; never use with oxidizers. | Parker O-ring Chemical Compatibility |
EPDM elastomer | Fair | 60 | Service below 35 %; swelling and embrittlement above. | Parker O-ring Chemical Compatibility |
Viton (FKM) elastomer | Poor | — | Use EPDM or PTFE for sealing | Solvay H2O2 Safety & Handling |
PTFE fluoropolymer | Excellent | 200 | Universal compatibility; preferred lining material. | Cole-Parmer Chemical Compatibility |
PVDF (Kynar) fluoropolymer | Excellent | 100 | Standard for high-purity peroxide service. | Solvay H2O2 Materials of Construction |
Borosilicate Glass glass ceramic | Excellent | 100 | Inert to all oxidizers within normal service temperatures. | Cole-Parmer Chemical Compatibility |
Concrete (untreated) glass ceramic | Not recommended | — | Reactive; line with HDPE/FRP | Solvay H2O2 Safety & Handling |
304 Stainless Steel metal | Fair | 40 | Surface oxidation at higher concentrations; passivate before service. | Cole-Parmer Chemical Compatibility |
316L Stainless Steel metal | Good | 60 | Passive layer stable; avoid prolonged service above 60 °C. | Solvay H2O2 Materials of Construction |
Aluminium 1100/3003 metal | Good | 40 | Limit to dilute service | Solvay H2O2 Safety & Handling |
Brass metal | Not recommended | — | Copper-induced decomposition | Solvay H2O2 Safety & Handling |
Carbon Steel metal | Not recommended | — | Rapid corrosion; never use with oxidizers. | Cole-Parmer Chemical Compatibility |
Copper metal | Not recommended | — | Catalytic decomposition; severe | Solvay H2O2 Safety & Handling |
CPVC thermoplastic | Good | 60 | Acceptable to 60 °C | Solvay H2O2 Safety & Handling |
HDPE thermoplastic | Good | 25 | Good below 25 °C; reaction with peroxides accelerates at higher T. | Cole-Parmer Chemical Compatibility |
Polypropylene thermoplastic | Good | 25 | Service below 35 % at ambient; avoid above 25 °C. | Cole-Parmer Chemical Compatibility |
PVC thermoplastic | Fair | 40 | Embrittlement risk above 40 °C | Solvay H2O2 Safety & Handling |
Ratings reflect the service envelope (concentration × temperature) shown. Always confirm against your specific duty cycle and contact-time before equipment selection. The most cautious rating across overlapping references is shown.
Showing 17 of 17 material ratings within the selected envelope.
| Material | Rating | Max T (°C) | Notes |
|---|---|---|---|
Buna-N (NBR) elastomer | Not recommended | — | Rapid degradation; never use with oxidizers. |
EPDM elastomer | Fair | 60 | Service below 35 %; swelling and embrittlement above. |
Viton (FKM) elastomer | Poor | — | Use EPDM or PTFE for sealing |
PTFE fluoropolymer | Excellent | 200 | Universal compatibility; preferred lining material. |
PVDF (Kynar) fluoropolymer | Excellent | 100 | Standard for high-purity peroxide service. |
Borosilicate Glass glass ceramic | Excellent | 100 | Inert to all oxidizers within normal service temperatures. |
Concrete (untreated) glass ceramic | Not recommended | — | Reactive; line with HDPE/FRP |
304 Stainless Steel metal | Fair | 40 | Surface oxidation at higher concentrations; passivate before service. |
316L Stainless Steel metal | Good | 60 | Passive layer stable; avoid prolonged service above 60 °C. |
Aluminium 1100/3003 metal | Good | 40 | Limit to dilute service |
Brass metal | Not recommended | — | Copper-induced decomposition |
Carbon Steel metal | Not recommended | — | Rapid corrosion; never use with oxidizers. |
Copper metal | Not recommended | — | Catalytic decomposition; severe |
CPVC thermoplastic | Good | 60 | Acceptable to 60 °C |
HDPE thermoplastic | Good | 25 | Good below 25 °C; reaction with peroxides accelerates at higher T. |
Polypropylene thermoplastic | Good | 25 | Service below 35 % at ambient; avoid above 25 °C. |
PVC thermoplastic | Fair | 40 | Embrittlement risk above 40 °C |
輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。
急性毒性値はSDS第11項またはNIOSH RTECSによる。
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Hydrogen Peroxide 6% ACS Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
| SKU | グレード | Conc. | Match | Notes |
|---|---|---|---|---|
| 95302 | ACS | 30% | Unverified candidate | Fluka brand, ACS grade |
| SKU | グレード | Conc. | Match | Notes |
|---|---|---|---|---|
| 216763 | ACS Reagent | 30% | Unverified candidate | Stabilized; ACS Reagent |
Cross-references are informational. Confirm against the manufacturer's current specification before substitution. Competitor trademarks are property of their respective owners.
Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Not regulated for transport.
Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.4 | 2026-10-08 | Canonical data updated: 22 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.3 | 2026-09-30 | Canonical data updated: 2 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.2 | 2026-09-10 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.1 | 2026-07-17 | Canonical data re-verified: 8 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.