Technical Data Sheet
Technical · 20%
| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Assay | 20.0 - 21.0 %, by volume | 20.06 % | — | Interpreted |
| Freeze point | 18.7 °F (-7.4 °C) max | 18.6 °F (-7.4 °C) | ASTM D1177 | Interpreted |
| Dilution water quality (conductivity @ 25 °C) | Deionized water; ≤ 10 µS/cm | 0.8 | ASTM D1125 | Interpreted |
| Dipropylene glycol (DPG) | 0.1 wt% max | 0.052 wt% | GC area % (ASTM E202) | Interpreted |
| Acidity as Acetic Acid | 0.001 % max | 0.00023 % | — | Interpreted |
| Chlorides as Cl | 0.52 ppm max | 0.111 ppm | — | Interpreted |
| Heavy Metals as Pb | 1 ppm max | 0.050 ppm | — | Interpreted |
| Iron | 0.21 ppm max | 0.023 ppm | — | Interpreted |
| ash | 0.001% max | 0.00021 % | — | Interpreted |
| Appearance | Pass | Passes test | — | Interpreted |
| Suspended Matter | Pass | Passes test | — | Interpreted |
| Composition | 20 % propylene glycol / 80 % deionized water, by volume | Conforms | By formulation; confirmed by specific gravity | Interpreted |
Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.
| グレード | 濃度 | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade Technical | 20% | — | current | current |
| — | 60% | — | propylene-glycol-60-inhibited | View TDS → |
| Technical | 60% | — | propylene-glycol-60-technical-grade | View TDS → |
| USP | 60% | — | propylene-glycol-60-usp-grade | View TDS → |
| USP Grade | 50% | — | 50-propylene-glycol-usp-grade | View TDS → |
| Technical Grade | 40% | — | 40-propylene-glycol-technical-grade | View TDS → |
| USP Grade | 40% | — | 40-propylene-glycol-usp-grade | View TDS → |
| — | 20% | — | propylene-glycol-20-inhibited | View TDS → |
| USP | 20% | — | propylene-glycol-20-usp-grade | View TDS → |
| Technical Grade | — | — | propylene-glycol-technical-grade | View TDS → |
| USP Grade | — | — | propylene-glycol-usp-grade | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
| Property | 値 | Source |
|---|---|---|
| 外観 | Clear, colorless to pale liquid | Adjudicated |
| 色 | 10 APHA (maximum) | Interpreted |
| 臭い | Mild, characteristic | Adjudicated |
| pH | Essentially neutral (unbuffered blend) | Adjudicated |
| 比重 | 1.022 (20 °C) | Adjudicated |
| 密度 | 1.022 g/mL at 20 °C | Adjudicated |
| 沸点 | ~101 °C | Adjudicated |
| 融点 | -7 °C (freeze / crystallization onset) | Adjudicated |
| 引火点 | Not flammable (aqueous solution) | Adjudicated |
| Solubility (water) | Miscible with water | Adjudicated |
輸送情報は発行時点の49 CFR 172.101の照会結果を反映しています。データ出典:REL/IDLHはNIOSH Pocket Guide、PELはOSHA Zテーブル。出荷に関わる重要な判断の前に、必ず最新の規制本文で確認してください。
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Propylene Glycol 20% Technical Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
即使用可能なpropylene glycolおよび水の混合物(20% PG):密閉系システム用熱媒体および不凍液;湿潤剤および溶剤キャリアAdjudicated
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Not regulated for transport.
Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-06-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.4 | 2026-10-13 | Canonical data updated: 5 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.3 | 2026-09-09 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.2 | 2026-07-24 | Canonical data updated: 1 field changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.1 | 2026-06-17 | Canonical data re-verified: 3 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.