Technical Data Sheet
ACS Reagent
| Test | Specification | Typical | Method | Source |
|---|---|---|---|---|
| Assay | Min 99.5% | 99.82% | — | Interpreted |
| Chloride | Max 0.001% | 0.00018% | — | Interpreted |
| Description | Fine granular | Passes test | — | Interpreted |
| Identification | To Pass Test | Passes test | — | Interpreted |
| Insoluble Matter | Max 0.005% | 0.0039% | — | Interpreted |
| Iron | Max 3 ppm | 0.22 ppm | — | Interpreted |
| Lead | Max 2 ppm | 0.028 ppm | — | Interpreted |
| Oxalate (C2O4) | To Pass Test | Passes test | — | Interpreted |
| Phosphate | Max 0.001% | 0.00010% | — | Interpreted |
| Residue after ignition | Max 0.02% | 0.0039% | — | Interpreted |
| Substances carbonizable by hot sulfuric acid | Passes test | Passes test | — | Interpreted |
| Sulfate | Max 0.002% | 0.00056% | — | Interpreted |
| Water (Karl Fischer) | Max 0.5% | 0.14% | Karl Fischer titration | Interpreted |
| arsenic | 1 ppm max | 0.037 ppm | — | Interpreted |
Values are reproduced from the current product reference. Source labels do not by themselves establish a supplier guarantee or a test result for your lot. Confirm applicable acceptance limits and request lot-specific documentation.
| Grade | Concentration | Typical Assay | SKU | TDS |
|---|---|---|---|---|
| This grade ACS Reagent | — | — | current | current |
| Technical | 50% | — | citric-acid-50-solution | View TDS → |
| Technical | 25% | — | citric-acid-25-solution | View TDS → |
| Food | — | — | citric-acid-anhydrous-food-grade | View TDS → |
Typical assay shown is the rolling-window mean from the sibling product's most recent lots. Grade selection drives downstream end-use — verify the sibling grade matches your specification before substitution.
| Property | Value | Source |
|---|---|---|
| Appearance | White crystalline powder | Adjudicated |
| Odor | Odorless | Published reference |
| Density | 1.54 at 68 °F (USCG, 1999) - Denser than water; will sink | Published reference |
| Boiling Point | Decomposes (NTP, 1992) | Published reference |
| Melting Point | 307 °F (anhydrous) (NTP, 1992) | Adjudicated |
| Flash Point | 100 °C | Adjudicated |
| Solubility (water) | greater than or equal to 100 mg/mL at 72 °F (NTP, 1992) | Published reference |
Transport descriptions reflect 49 CFR 172.101 lookup at time of publication. Sourced data: NIOSH Pocket Guide for REL/IDLH, OSHA Z-Tables for PEL. Always verify against the latest regulatory text before shipment-critical decisions.
One zipped download containing the TDS, SDS, latest lot COA (when available), and a fresh Letter of Continuing Guaranty for Citric Acid Anhydrous - ACS Reagent Grade. Every file included is SHA-256 hashed and listed in a manifest your QA team can audit.
Applications are drawn from published manufacturer and supplier documentation; each is sourced. Suitability for a specific use is the buyer's to confirm.
For full hazard, PPE, and emergency response guidance, refer to the Safety Data Sheet (SDS) for this product. The SDS controls in all cases where guidance differs.
Not regulated for transport.
Confirm against shipping documents and carrier requirements before tender.
Last reviewed 2026-07-17 by Andre Taki, Chief Commercial Officer, DOT Hazmat–certified (49 CFR 172.704).
| Version | Date | Change | Trigger |
|---|---|---|---|
| 1.4 | 2026-10-13 | Canonical data updated: 4 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.3 | 2026-10-07 | Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.2 | 2026-09-30 | Canonical data updated: 3 fields changed via the provenance/adjudication pipeline.
| canonical_change |
| 1.1 | 2026-07-17 | Canonical data re-verified: 10 fields updated against independent vendor SDSs, CLP Annex VI, 49 CFR, and OSHA HazCom 2024 (GHS classification, hazard/precautionary codes, signal word, physical properties as applicable).
| canonical_change |
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
This Technical Data Sheet is provided for technical reference. The Safety Data Sheet (SDS) controls in all cases where guidance differs. Values reflect Alliance Chemical canonical data at time of generation; subsequent revisions are recorded in the Revision History above.