Hoja de datos técnicos
Technical Grade · 5%
| Grado | Concentración | Ensayo típico | SKU | TDS |
|---|---|---|---|---|
| Este grado Technical Grade | 5% | — | actual | actual |
| ACS Grade | 30% | — | hydrogen-peroxide-30-acs-grade | Ver la TDS → |
| ACS Grade | 25% | — | hydrogen-peroxide-25-acs-grade | Ver la TDS → |
| Technical Grade | 25% | — | hydrogen-peroxide-25-technical-grade | Ver la TDS → |
| ACS Grade | 15% | — | hydrogen-peroxide-15-acs-grade | Ver la TDS → |
| ACS Grade | 12% | — | hydrogen-peroxide-12-acs-grade | Ver la TDS → |
| Technical Grade | 12% | — | hydrogen-peroxide-12-technical-grade | Ver la TDS → |
| ACS Grade | 10% | — | hydrogen-peroxide-10-acs-grade | Ver la TDS → |
| Technical Grade | 10% | — | hydrogen-peroxide-10-technical-grade | Ver la TDS → |
| ACS Grade | 6% | — | hydrogen-peroxide-6-acs-grade | Ver la TDS → |
| Technical Grade | 6% | — | hydrogen-peroxide-6-technical-grade | Ver la TDS → |
| ACS Grade | 5% | — | hydrogen-peroxide-5-acs-grade | Ver la TDS → |
| Technical Grade | 3% | — | hydrogen-peroxide-3-technical-grade | Ver la TDS → |
El ensayo típico mostrado es la media de ventana móvil de los lotes más recientes del producto análogo. La selección del grado determina el uso final posterior: verifique que el grado análogo coincida con su especificación antes de sustituirlo.
Uno o más valores de propiedad física están temporalmente ocultos a la espera de verificación con los datos del CdA del proveedor. Para conocer las propiedades completas, consulte la ficha de datos de seguridad (FDS) o póngase en contacto con sales@alliancechemical.com.
Comburente — pueden aplicarse la velocidad de descomposición y los datos de desprendimiento de gases. Consulte la FDS para obtener orientación sobre los materiales de construcción en condiciones de transporte y almacenamiento.
| Material | Calificación | T máx (°C) | Notas | Fuente |
|---|---|---|---|---|
Buna-N (NBR) elastomer | No recomendado | — | Rapid degradation; never use with oxidizers. | Parker O-ring Chemical Compatibility |
EPDM elastomer | Aceptable | 60 | Service below 35 %; swelling and embrittlement above. | Parker O-ring Chemical Compatibility |
Viton (FKM) elastomer | Deficiente | — | Use EPDM or PTFE for sealing | Solvay H2O2 Safety & Handling |
PTFE fluoropolymer | Excelente | 100 | Gaskets, lining; best-in-class | Solvay H2O2 Safety & Handling |
PVDF fluoropolymer | Excelente | 80 | Preferred fluoropolymer for piping | Solvay H2O2 Safety & Handling |
PVDF (Kynar) fluoropolymer | Excelente | 100 | Standard for high-purity peroxide service. | Solvay H2O2 Materials of Construction |
Borosilicate Glass glass ceramic | Excelente | 100 | Inert to all oxidizers within normal service temperatures. | Cole-Parmer Chemical Compatibility |
Concrete (untreated) glass ceramic | No recomendado | — | Reactive; line with HDPE/FRP | Solvay H2O2 Safety & Handling |
304 stainless steel metal | Bueno | 40 | May darken; acceptable for short-term storage | Solvay H2O2 Safety & Handling |
304 Stainless Steel metal | Aceptable | 40 | Surface oxidation at higher concentrations; passivate before service. | Cole-Parmer Chemical Compatibility |
316 stainless steel metal | Excelente | 40 | Passivated surfaces preferred | Solvay H2O2 Safety & Handling |
316L stainless steel metal | Excelente | 60 | Welds require post-weld passivation | Solvay H2O2 Safety & Handling |
316L Stainless Steel metal | Bueno | 60 | Passive layer stable; avoid prolonged service above 60 °C. | Solvay H2O2 Materials of Construction |
Aluminium 1100/3003 metal | Bueno | 40 | Limit to dilute service | Solvay H2O2 Safety & Handling |
Brass metal | No recomendado | — | Copper-induced decomposition | Solvay H2O2 Safety & Handling |
Carbon steel metal | No recomendado | — | Catalytic decomposition; not for any service | Solvay H2O2 Safety & Handling |
Carbon Steel metal | No recomendado | — | Rapid corrosion; never use with oxidizers. | Cole-Parmer Chemical Compatibility |
Copper metal | No recomendado | — | Catalytic decomposition; severe | Solvay H2O2 Safety & Handling |
CPVC thermoplastic | Bueno | 60 | Acceptable to 60 °C | Solvay H2O2 Safety & Handling |
HDPE thermoplastic | Bueno | 50 | Concentrations ≤ 50%; vented containers only | Solvay H2O2 Safety & Handling |
Polypropylene thermoplastic | Bueno | 25 | Service below 35 % at ambient; avoid above 25 °C. | Cole-Parmer Chemical Compatibility |
PVC thermoplastic | Aceptable | 40 | Embrittlement risk above 40 °C | Solvay H2O2 Safety & Handling |
Las calificaciones reflejan la envolvente de servicio (concentración × temperatura) indicada. Confirme siempre con su ciclo de trabajo y tiempo de contacto específicos antes de seleccionar el equipo. Se muestra la calificación más cautelosa entre las referencias que se solapan.
Mostrando 22 de 22 materiales compatibles en la envolvente seleccionada.
| Material | Calificación | T máx (°C) | Notas |
|---|---|---|---|
Buna-N (NBR) elastomer | No recomendado | — | Rapid degradation; never use with oxidizers. |
EPDM elastomer | Aceptable | 60 | Service below 35 %; swelling and embrittlement above. |
Viton (FKM) elastomer | Deficiente | — | Use EPDM or PTFE for sealing |
PTFE fluoropolymer | Excelente | 100 | Gaskets, lining; best-in-class |
PVDF fluoropolymer | Excelente | 80 | Preferred fluoropolymer for piping |
PVDF (Kynar) fluoropolymer | Excelente | 100 | Standard for high-purity peroxide service. |
Borosilicate Glass glass ceramic | Excelente | 100 | Inert to all oxidizers within normal service temperatures. |
Concrete (untreated) glass ceramic | No recomendado | — | Reactive; line with HDPE/FRP |
304 stainless steel metal | Bueno | 40 | May darken; acceptable for short-term storage |
304 Stainless Steel metal | Aceptable | 40 | Surface oxidation at higher concentrations; passivate before service. |
316 stainless steel metal | Excelente | 40 | Passivated surfaces preferred |
316L stainless steel metal | Excelente | 60 | Welds require post-weld passivation |
316L Stainless Steel metal | Bueno | 60 | Passive layer stable; avoid prolonged service above 60 °C. |
Aluminium 1100/3003 metal | Bueno | 40 | Limit to dilute service |
Brass metal | No recomendado | — | Copper-induced decomposition |
Carbon steel metal | No recomendado | — | Catalytic decomposition; not for any service |
Carbon Steel metal | No recomendado | — | Rapid corrosion; never use with oxidizers. |
Copper metal | No recomendado | — | Catalytic decomposition; severe |
CPVC thermoplastic | Bueno | 60 | Acceptable to 60 °C |
HDPE thermoplastic | Bueno | 50 | Concentrations ≤ 50%; vented containers only |
Polypropylene thermoplastic | Bueno | 25 | Service below 35 % at ambient; avoid above 25 °C. |
PVC thermoplastic | Aceptable | 40 | Embrittlement risk above 40 °C |
Las descripciones de transporte reflejan la consulta del 49 CFR 172.101 en el momento de la publicación. Datos de origen: anexo VI del Reglamento CLP de la ECHA para las clasificaciones armonizadas, NIOSH Pocket Guide para REL/IDLH, tablas Z de la OSHA para PEL. Verifique siempre con el texto reglamentario más reciente antes de tomar decisiones críticas para el envío.
Una única descarga comprimida que contiene la FTP, la FDS, el CdA del último lote (cuando esté disponible) y una Carta de Garantía Continua reciente para Hydrogen Peroxide 5% Technical Grade. Cada archivo incluido lleva un hash SHA-256 y figura en un manifiesto que su equipo de CC puede auditar.
| SKU | Grado | Conc. | Coincidencia | Notas |
|---|---|---|---|---|
| 95302 | ACS | 30% | Exacta | Fluka brand, ACS grade |
| SKU | Grado | Conc. | Coincidencia | Notas |
|---|---|---|---|---|
| 216763 | ACS Reagent | 30% | Exacta | Stabilized; ACS Reagent |
Las referencias cruzadas son meramente informativas. Verifique la especificación vigente del fabricante antes de cualquier sustitución. Las marcas de los competidores son propiedad de sus respectivos titulares.
Hydrogen Peroxide 5% Technical Grade (Technical Grade) se suministra para aplicaciones que requieren una oxidación controlada y selectiva. La selección del grado determina la elección entre la oxidación industrial a granel, la limpieza de electrónica/semiconductores y la desinfección de grado farmacéutico.
Los materiales de construcción deben estar homologados para la concentración y la temperatura de servicio. Evite el contacto con agentes reductores, metales de transición y combustibles orgánicos.
Para obtener orientación completa sobre peligros, EPP y respuesta a emergencias, consulte la ficha de datos de seguridad (FDS) de este producto. La FDS prevalece en todos los casos en que la orientación difiera.
Última revisión el 2026-05-20 por Hossein Taki, Vice President (Vice President, Alliance Chemical · CAGE Code 1LT50 · DOT Hazmat Registrant #2188383).
| Versión | Fecha | Cambio | Desencadenante |
|---|---|---|---|
| 1.0 | 2026-05-20 | Initial URL-first TDS published from canonical chemistry registry. | initial |
Esta hoja de datos técnicos se proporciona como referencia técnica. La ficha de datos de seguridad (FDS) prevalece en todos los casos en que la orientación difiera. Los valores reflejan los datos canónicos de Alliance Chemical en el momento de la generación; las revisiones posteriores se registran en el historial de revisiones anterior.